Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Spectrosc ; 72(6): 964-970, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29154673

ABSTRACT

Diode laser-based two-line atomic fluorescence (TLAF) thermometry applied to flames of combusting wood pellets is demonstrated. The temperature above burning wood pellets placed in the hot product gas of gallium seeded laminar flames is measured. The calibration-free technique provides spatially resolved temperatures in one dimension with sufficient temporal resolution to resolve all combustion stages of a pellet, even in highly sooting flames. The temperature above a burning pellet was found to decrease due to the release of volatile gases and the accuracy and precision of the technique is assessed at flame temperatures.

2.
Rev Sci Instrum ; 88(4): 045104, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28456221

ABSTRACT

A novel multi-jet burner was built to provide one-dimensional laminar flat flames with a wide range of variable parameters for multipurpose quantitative optical measurements. The burner is characterized by two independent plenum chambers, one supporting a matrix of 181 laminar jet flames and the other supporting a co-flow from a perforated plate with small holes evenly distributed among the jets. A uniform rectangular burned gas region of 70 mm × 40 mm can be generated, with a wide range of temperatures and equivalence ratios by controlling independently the gas supplies to the two plenum chambers. The temperature of the hot gas can be adjusted from 1000 K to 2000 K with different flame conditions. The burner is designed to seed additives in gas or liquid phase to study homogeneous reactions. The large uniform region can be used to burn solid fuels and study heterogeneous reactions. The temperature was measured using two-line atomic fluorescence thermometry and the temperature profile at a given height above the burner was found to be flat. Different types of optical diagnostic techniques, such as line of sight absorption or laser-induced fluorescence, can be easily applied in the burner, and as examples, two typical measurements concerning biomass combustion are demonstrated.

3.
Appl Phys B ; 123(12): 278, 2017.
Article in English | MEDLINE | ID: mdl-31997853

ABSTRACT

A robust and relatively compact calibration-free thermometric technique using diode lasers two-line atomic fluorescence (TLAF) for reactive flows at atmospheric pressures is investigated. TLAF temperature measurements were conducted using indium and, for the first time, gallium atoms as temperature markers. The temperature was measured in a multi-jet burner running methane/air flames providing variable temperatures ranging from 1600 to 2000 K. Indium and gallium were found to provide a similar accuracy of ~ 2.7% and precision of ~ 1% over the measured temperature range. The reliability of the TLAF thermometry was further tested by performing simultaneous rotational CARS measurements in the same experiments.

4.
Opt Lett ; 40(21): 5019-22, 2015 Nov 01.
Article in English | MEDLINE | ID: mdl-26512508

ABSTRACT

A laser method to suppress background interferences in pump-probe measurements is presented and demonstrated. The method is based on structured illumination, where the intensity profile of the pump beam is spatially modulated to make its induced photofragment signal distinguishable from that created solely by the probe beam. A spatial lock-in algorithm is then applied on the acquired data, extracting only those image components that are characterized by the encoded structure. The concept is demonstrated for imaging of OH photofragments in a laminar methane/air flame, where the signal from the OH photofragments produced by the pump beam is spatially overlapping with that from the naturally present OH radicals. The purpose was to perform for the first time, to the best of our knowledge, single-shot imaging of HO(2) in a flame. These results show an increase in signal-to-interference ratio of about 20 for single-shot data.

SELECTION OF CITATIONS
SEARCH DETAIL
...