Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Publication year range
1.
Sensors (Basel) ; 21(5)2021 Mar 04.
Article in English | MEDLINE | ID: mdl-33806532

ABSTRACT

The surf pop-up is a unique and challenging skill, critical to successful surfing. Hypothesizing that anthropometric characteristics of surfers influence the pop-up performance, we aimed to measure kinematics and ground-reaction forces (GRF) during a simulated pop-up motion, and to relate these variables with anthropometric characteristics. Twenty-three male surfers (age: 28.4 ± 10.1 years old; body mass: 68.3 ± 10.8 kg; height: 1.73 ± 0.07 m; time of practice: 12.4 ± 8.9 years; arm-span: 1.75 ± 8.9 m) perform a simulated pop-up in the laboratory, while GRF and 3D motion-capture data were acquired. The duration of the pop-up was 1.20 ± 0.19 s (60% push-up and 40% reaching/landing phase). During the push-up, the hands were placed 0.46 ± 0.05 m apart and generated a relative total peak-force of 0.99 ± 0.10 N/Weight, with symmetrical impulse of 0.30 ± 0.05 N·s/Weight for the dominant and 0.29 ± 0.07 N·s/Weight for the nondominant hand. Elbow angles were not different during the peak force application (110 ± 18° vs. 112 ± 18°, respectively) of the push-up phase. During the landing phase, the feet were placed 0.63 ± 0.10 m apart and generated a relative peak force of 1.63 ± 0.18 N/Weight. The impact force during landing was applied unevenly between the rear foot (28%) and the front foot (72%). In conclusion, most anthropometric-related variables showed no relationship with performance variables, with the exception of an inverse relationship between muscle mass and pop-up total duration. We also observed no differences in upper- and lower-body kinematics between the dominant vs. nondominant hands and among surfers who preferred a regular vs. "goofy-foot" stance. Finally, the force profiles between hands were similar and symmetric, while the lower extremities during the reaching phase were different, with the front foot applying greater force than that of the rear foot.

2.
Article in English | MEDLINE | ID: mdl-33672908

ABSTRACT

We compared the hydrodynamic characteristics and pull-out strategies of four backstroke-to-breaststroke turning techniques in young swimmers. Eighteen 11 and 12-year-old swimmers participated in a 4 week intervention program including 16 contextual interference sessions. The hydrodynamic variables were assessed through inverse dynamics, and the pull-out strategy kinematics were assessed with tracking markers followed by 12 land cameras and 11 underwater cameras. Swimmers randomly completed sixteen 30 m maximal backstroke-to breaststroke-open, somersault, bucket and crossover turns (four in each technique) with a 3 min rest. The data showed higher drag force, cross-sectional area and drag coefficient values for the first (compared with the second) gliding position. The crossover turn revealed the highest push-off velocity (2.17 ± 0.05 m·s-1), and the somersault turn demonstrated the lowest foot plant index (0.68 ± 0.03; 68%), which could have affected the first gliding, transition and second gliding depths (0.73 ± 0.13, 0.86 ± 0.17 and 0.76 ± 0.17 m). The data revealed the consistency of the time spent (4.86 ± 0.98 s) and breakout distance (6.04 ± 0.94 m) among the four turning techniques, and no differences were observed between them regarding time and average velocity up to 7.5 m. The hydrodynamic characteristics and pull-out strategy of the backstroke-to-breaststroke turns performed by the age group swimmers were independent of the selected technique.


Subject(s)
Athletic Performance , Hydrodynamics , Biomechanical Phenomena , Foot , Swimming
3.
Sci Rep ; 11(1): 4566, 2021 02 25.
Article in English | MEDLINE | ID: mdl-33633202

ABSTRACT

Surfing is one additional sport proposed by the Tokyo 2020 Organizing Committee. Surprisingly, substantial efforts to understand surfing energetics are recent, and the impact of a single surfing paddling cycle on fatigue and energy cost is still not clear. Since surfing paddling technique is highly specific, experiments in real practice conditions are necessary to provide deeper insights. Through a biophysical approach, biomechanical and energetics responses of surfing paddling were quantified and compared from 16 competitive male surfers (23.5 ± 10.0 years old, 65.3 ± 11.4 kg and 1.72 ± 0.01 m) during two sets (PRE and POST) of 10 s all-out tethered paddling plus 20 m sprint paddling, interposed by 6 min of endurance paddling. Faster surfers presented lower energy cost during sprint PRE (r2 = 0.30, p = 0.03) and endurance (r2 = 0.35, p = 0.02) relative surfing paddling velocities. Although the energy cost was higher for a lower velocity at maximal paddling velocity POST, the energy cost of surfing paddling increased with absolute velocity according to a power function (R2 = 0.83). Our results suggest that fatigue seems to occur even following a single surfing paddling cycle. Developing a powerful and endurable metabolic base while reducing energy cost during surfing paddling should be seen as key factors in surfing training programs.


Subject(s)
Energy Metabolism , Fatigue/etiology , Fatigue/metabolism , Sports , Adult , Aged , Algorithms , Athletic Performance , Biomarkers , Hematologic Tests , Humans , Male , Middle Aged , Models, Theoretical , Teaching , Young Adult
4.
Hum Mov Sci ; 72: 102632, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32452388

ABSTRACT

INTRODUCTION: Recently, kinematic analysis of the drinking task (DRINK) has been recommended to assess the quality of upper limb (UL) movement after stroke, but the accomplishment of this task may become difficult for poststroke patients with hand impairment. Therefore, it is necessary to study ADLs that involve a simpler interaction with a daily life target, such as the turning on a light task (LIGHT). As the knowledge of movement performed by healthy adults becomes essential to assess the quality of movement of poststroke patients, the main goal of this article was to compare the kinematic strategies used by healthy adults in LIGHT with those that are used in DRINK. METHODS: 63 adults, aged 30 to 69 years old, drank water and turned on a light, using both ULs separately, while seated. The movements of both tasks were captured by a 3D motion capture system. End-point and joint kinematics of reaching and returning phases were analysed. A multifactorial analysis of variance with repeated measures was applied to the kinematic metrics, using age, sex, body mass index and dominance as main factors. RESULTS: Mean and peak velocities, index of curvature, shoulder flexion and elbow extension were lower in LIGHT, which suggests that the real hand trajectory was smaller in this task. In LIGHT, reaching was less smooth and returning was smoother than DRINK. The instant of peak velocity was similar in both tasks. There was a minimal anterior trunk displacement in LIGHT, and a greater anterior trunk displacement in DRINK. Age and sex were the main factors which exerted effect on some of the kinematics, especially in LIGHT. CONCLUSION: The different target formats and hand contact in DRINK and LIGHT seem to be responsible for differences in velocity profile, efficiency, smoothness, joint angles and trunk displacement. Results suggest that the real hand trajectory was smaller in LIGHT and that interaction with the switch seems to be less demanding than with the glass. Accordingly, LIGHT could be a good option for the assessment of poststroke patients without grasping ability. Age and sex seem to be the main factors to be considered in future studies for a better match between healthy and poststroke adults.


Subject(s)
Activities of Daily Living , Hand Strength/physiology , Movement , Range of Motion, Articular , Upper Extremity/physiology , Adult , Aged , Biomechanical Phenomena , Cross-Sectional Studies , Elbow/physiology , Elbow Joint/physiology , Female , Hand/physiology , Humans , Male , Middle Aged , Shoulder/physiology
5.
Sports Biomech ; 18(1): 39-50, 2019 Feb.
Article in English | MEDLINE | ID: mdl-29199523

ABSTRACT

The aim of the present study was to determine which approach to calculating shoulder ratios is the most sensitive for determining shoulder torque imbalance in handball players. Twenty-six participants (handball athletes, n = 13; healthy controls, n = 13) performed isokinetic concentric and eccentric shoulder internal rotation (IR) and external rotation (ER) assessment at 60, 180 and 300°/s. We used eight approaches to calculating shoulder ratios: four concentric (i.e. concentric ER torque divided by concentric IR torque), and four functional (i.e. eccentric ER torque divided by concentric IR torque) at the velocities of 60, 180 and 300°/s for both IR and ER, and combining 60°/s of ER and 300°/s of IR. A three factorial ANOVA (factors: shoulder ratios, upper limb sides, and groups) along with Tukey's post-hoc analysis, and effect sizes were calculated. The findings suggested the functional shoulder ratio combining 60°/s of ER and 300°/s of IR is the most sensitive to detect differences between upper limbs for handball players, and between players and controls for the dominant side. The functional shoulder ratio combining 60°/s of ER with 300°/s of IR seems to present advantages over the other approaches for identifying upper limb asymmetries and differences in shoulder torque balance related to throwing.


Subject(s)
Rotation , Shoulder/physiology , Torque , Adult , Athletes , Biomechanical Phenomena , Cross-Sectional Studies , Functional Laterality , Humans , Male , Muscle Contraction , Sports , Young Adult
6.
Sports Biomech ; 15(4): 481-96, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27268463

ABSTRACT

Foot and hand set-up position effects were analysed on backstroke start performance. Ten swimmers randomly completed 27 starts grouped in trials (n = 3) of each variation, changing foot (totally immersed, partially and totally emerged) and hand (lowest, highest horizontal and vertical) positioning. Fifteen cameras recorded kinematics, and four force plates collected hands and feet kinetics. Standardised mean difference and 95% confidence intervals were used. Variations with feet immersed have shown lower vertical centre of mass (CM) set-up position (0.16 m), vertical impulse exerted at the hands, horizontal and vertical impulse exerted at the feet (0.28, 0.41, 0.16 N/BW.s, respectively) than feet emerged with hands horizontal and vertically positioned. Most variations with feet partially emerged exhibited higher and lesser vertical impulse exerted at hands than feet immersed and emerged (e.g. vertical handgrip, 0.13, 0.15 N/BW.s, respectively). Variation with feet emerged and hands on the lowest horizontal handgrip depicted shorter horizontal (0.23, 0.26 m) and vertical CM positioning at flight (0.16, 0.15 m) than the highest horizontal and vertical handgrip, respectively. Start variations have not affected 15-m time. Variations with feet partially or totally emerged depicted advantages, but focusing on the entry and underwater biomechanics is relevant for a shorter start time.


Subject(s)
Athletic Performance/physiology , Foot/physiology , Hand/physiology , Physical Conditioning, Human/methods , Swimming/physiology , Biomechanical Phenomena , Competitive Behavior/physiology , Humans , Male , Time and Motion Studies , Young Adult
7.
Biomed Res Int ; 2014: 348659, 2014.
Article in English | MEDLINE | ID: mdl-24701570

ABSTRACT

WalkinSense is a new device designed to monitor walking. The aim of this study was to measure the accuracy and repeatability of the gait analysis performed by the WalkinSense system. Descriptions of values recorded by WalkinSense depicting typical gait in adults are also presented. A bench experiment using the Trublu calibration device was conducted to statically test the WalkinSense. Following this, a dynamic test was carried out overlapping the WalkinSense and the Pedar insoles in 40 healthy participants during walking. Pressure peak, pressure peak time, pressure-time integral, and mean pressure at eight-foot regions were calculated. In the bench experiments, the repeatability (i) among the WalkinSense sensors (within), (ii) between two WalkinSense devices, and (iii) between the WalkinSense and the Trublu devices was excellent. In the dynamic tests, the repeatability of the WalkinSense (i) between stances in the same trial (within-trial) and (ii) between trials was also excellent (ICC > 0.90). When the eight-foot regions were analyzed separately, the within-trial and between-trials repeatability was good-to-excellent in 88% (ICC > 0.80) of the data and fair in 11%. In short, the data suggest that the WalkinSense has good-to-excellent levels of accuracy and repeatability for plantar pressure variables.


Subject(s)
Gait/physiology , Walking/physiology , Adult , Female , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...