Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Opt Express ; 32(10): 18334-18351, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38858992

ABSTRACT

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

2.
J Neural Eng ; 20(5)2023 Oct 06.
Article in English | MEDLINE | ID: mdl-37748476

ABSTRACT

Objective.Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject's scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses.Approach.We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding.Main results.OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement.Significance.The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain-computer interfacing.

3.
ArXiv ; 2023 May 31.
Article in English | MEDLINE | ID: mdl-37396603

ABSTRACT

In magnetoencephalography, linear minimum norm inverse methods are commonly employed when a solution with minimal a priori assumptions is desirable. These methods typically produce spatially extended inverse solutions, even when the generating source is focal. Various reasons have been proposed for this effect, including intrisic properties of the minimum norm solution, effects of regularization, noise, and limitations of the sensor array. In this work, we express the lead field in terms of the magnetostatic multipole expansion and develop the minimum-norm inverse in the multipole domain. We demonstrate the close relationship between numerical regularization and explicit suppression of spatial frequencies of the magnetic field. We show that the spatial sampling capabilities of the sensor array and regularization together determine the resolution of the inverse solution. For the purposes of stabilizing the inverse estimate, we propose the multipole transformation of the lead field as an alternative or complementary means to purely numerical regularization.

4.
Phys Med Biol ; 68(9)2023 04 27.
Article in English | MEDLINE | ID: mdl-37040782

ABSTRACT

Objectives.We aim to investigate the effects of head model inaccuracies on signal and source reconstruction accuracies for various sensor array distances to the head. This allows for the assessment of the importance of head modeling for next-generation magnetoencephalography (MEG) sensors, optically-pumped magnetometers (OPM).Approach.A 1-shell boundary element method (BEM) spherical head model with 642 vertices of radius 9 cm and conductivity of 0.33 S m-1was defined. The vertices were then randomly perturbed radially up to 2%, 4%, 6%, 8% and 10% of the radius. For each head perturbation case, the forward signal was calculated for dipolar sources located at 2 cm, 4 cm, 6 cm and 8 cm from the origin (center of the sphere), and for a 324 sensor array located at 10 cm to 15 cm from the origin. Equivalent current dipole (ECD) source localization was performed for each of these forward signals. The signal for each perturbed spherical head case was then analyzed in the spatial frequency domain, and the signal and ECD errors were quantified relative to the unperturbed case.Main results.In the noiseless and high signal-to-noise ratio (SNR) case of approximately ≥6 dB, inaccuracies in our spherical BEM head conductor models lead to increased signal and ECD inaccuracies when sensor arrays are placed closer to the head. This is true especially in the case of deep and superficial sources. In the noisy case however, the higher SNR for closer sensor arrays allows for an improved ECD fit and outweighs the effects of head geometry inaccuracies.Significance.OPMs may be placed directly on the head, as opposed to the more commonly used superconducting quantum interference device sensors which must be placed a few centimeters away from the head. OPMs thus allow for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localizations. Our results suggest that an increased emphasis on accurate head modeling for OPMs may be necessary to fully realize its improved source localization potential.


Subject(s)
Head , Magnetoencephalography , Electric Conductivity , Signal-To-Noise Ratio , Brain
5.
ArXiv ; 2023 Dec 22.
Article in English | MEDLINE | ID: mdl-38196753

ABSTRACT

We present a novel four-channel OPM sensor for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

6.
Sensors (Basel) ; 22(8)2022 Apr 15.
Article in English | MEDLINE | ID: mdl-35459044

ABSTRACT

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.


Subject(s)
Brain , Magnetoencephalography , Brain/physiology , Calibration , Electromagnetic Phenomena , Magnetic Fields , Magnetoencephalography/methods
7.
Front Physiol ; 13: 798376, 2022.
Article in English | MEDLINE | ID: mdl-35370794

ABSTRACT

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere's Law, generates a small magnetic field that is also detected as an "action current" by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

8.
Neuroimage ; 247: 118818, 2022 02 15.
Article in English | MEDLINE | ID: mdl-34915157

ABSTRACT

Optically pumped magnetometers (OPMs) developed for magnetoencephalography (MEG) typically operate in the spin-exchange-relaxation-free (SERF) regime and measure a magnetic field component perpendicular to the propagation axis of the optical-pumping photons. The most common type of OPM for MEG employs alkali atoms, e.g. 87Rb, as the sensing element and one or more lasers for preparation and interrogation of the magnetically sensitive states of the alkali atoms ensemble. The sensitivity of the OPM can be greatly enhanced by operating it in the SERF regime, where the alkali atoms' spin exchange rate is much faster than the Larmor precession frequency. The SERF regime accommodates remnant static magnetic fields up to ±5 nT. However, in the presented work, through simulation and experiment, we demonstrate that multi-axis magnetic signals in the presence of small remnant static magnetic fields, not violating the SERF criteria, can introduce significant error terms in OPM's output signal. We call these deterministic errors cross-axis projection errors (CAPE), where magnetic field components of the MEG signal perpendicular to the nominal sensing axis contribute to the OPM signal giving rise to substantial amplitude and phase errors. Furthermore, through simulation, we have discovered that CAPE can degrade localization and calibration accuracy of OPM-based magnetoencephalography (OPM-MEG) systems.


Subject(s)
Magnetoencephalography/instrumentation , Magnetometry/instrumentation , Optical Phenomena , Algorithms , Computer Simulation , Equipment Design , Signal Processing, Computer-Assisted
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 6543-6546, 2021 11.
Article in English | MEDLINE | ID: mdl-34892608

ABSTRACT

Neural speech decoding aims at providing natural rate communication assistance to patients with locked-in state (e.g. due to amyotrophic lateral sclerosis, ALS) in contrast to the traditional brain-computer interface (BCI) spellers which are slow. Recent studies have shown that Magnetoencephalography (MEG) is a suitable neuroimaging modality to study neural speech decoding considering its excellent temporal resolution that can characterize the fast dynamics of speech. Gradiometers have been the preferred choice for sensor space analysis with MEG, due to their efficacy in noise suppression over magnetometers. However, recent development of optically pumped magnetometers (OPM) based wearable-MEG devices have shown great potential in future BCI applications, yet, no prior study has evaluated the performance of magnetometers in neural speech decoding. In this study, we decoded imagined and spoken speech from the MEG signals of seven healthy participants and compared the performance of magnetometers and gradiometers. Experimental results indicated that magnetometers also have the potential for neural speech decoding, although the performance was significantly lower than that obtained with gradiometers. Further, we implemented a wavelet based denoising strategy that improved the performance of both magnetometers and gradiometers significantly. These findings reconfirm that gradiometers are preferable in MEG based decoding analysis but also provide the possibility towards the use of magnetometers (or OPMs) for the development of the next-generation speech-BCIs.


Subject(s)
Speech , Wearable Electronic Devices , Humans , Magnetoencephalography , Neuroimaging
10.
PLoS One ; 15(1): e0227684, 2020.
Article in English | MEDLINE | ID: mdl-31978102

ABSTRACT

A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject's scalp. We have conducted two MEG experiments on three subjects: assessment of somatosensory evoked magnetic field (SEF) and auditory evoked magnetic field (AEF) using our OPM-based MEG system and a commercial MEG system based on superconducting quantum interference devices (SQUIDs). We cross validated the robustness of our system by calculating the distance between the location of the equivalent current dipole (ECD) yielded by our OPM-based MEG system and the ECD location calculated by the commercial SQUID-based MEG system. We achieved sub-centimeter accuracy for both SEF and AEF responses in all three subjects. Due to the proximity (12 mm) of the OPM channels to the scalp, it is anticipated that future OPM-based MEG systems will offer enhanced spatial resolution as they will capture finer spatial features compared to traditional MEG systems employing SQUIDs.


Subject(s)
Brain/diagnostic imaging , Brain/physiology , Functional Neuroimaging/instrumentation , Magnetoencephalography/instrumentation , Adult , Brain Mapping/instrumentation , Brain Mapping/methods , Brain Mapping/statistics & numerical data , Equipment Design , Evoked Potentials, Auditory/physiology , Evoked Potentials, Somatosensory/physiology , Functional Neuroimaging/methods , Functional Neuroimaging/statistics & numerical data , Humans , Magnetoencephalography/methods , Magnetoencephalography/statistics & numerical data , Male , Optical Devices , Signal Processing, Computer-Assisted , Superconductivity
11.
IEEE Trans Instrum Meas ; 68(2): 493-501, 2019 Feb.
Article in English | MEDLINE | ID: mdl-31777404

ABSTRACT

We have developed a pulsed optically pumped magnetometer (OPM) array for detecting magnetic field maps originated from an arbitrary current distribution. The presented magnetic source imaging (MSI) system features 24 OPM channels, has a data rate of 500 S/s, a sensitivity of 0.8 p T / H z , and a dynamic range of 72 dB. We have employed our pulsed- OPM MSI system for measuring the magnetic field map of a test coil structure. The coils are moved across the array in an indexed fashion to measure the magnetic field over an area larger than the array. The captured magnetic field maps show excellent agreement with the simulation results. Assuming a 2D current distribution, we have solved the inverse problem, using the measured magnetic field maps, and the reconstructed current distribution image is compared to that of the simulation.

12.
Phys Med Biol ; 62(23): 8909-8923, 2017 Nov 10.
Article in English | MEDLINE | ID: mdl-29035875

ABSTRACT

We describe a multichannel magnetoencephalography (MEG) system that uses optically pumped magnetometers (OPMs) to sense the magnetic fields of the human brain. The system consists of an array of 20 OPM channels conforming to the human subject's head, a person-sized magnetic shield containing the array and the human subject, a laser system to drive the OPM array, and various control and data acquisition systems. We conducted two MEG experiments: auditory evoked magnetic field and somatosensory evoked magnetic field, on three healthy male subjects, using both our OPM array and a 306-channel Elekta-Neuromag superconducting quantum interference device (SQUID) MEG system. The described OPM array measures the tangential components of the magnetic field as opposed to the radial component measured by most SQUID-based MEG systems. Herein, we compare the results of the OPM- and SQUID-based MEG systems on the auditory and somatosensory data recorded in the same individuals on both systems.


Subject(s)
Magnetoencephalography/instrumentation , Magnetometry/instrumentation , Optical Phenomena , Adult , Brain/physiology , Humans , Magnetic Fields , Male
13.
Opt Express ; 24(14): 15403-16, 2016 Jul 11.
Article in English | MEDLINE | ID: mdl-27410816

ABSTRACT

We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz1/2, and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. This module will serve as a building block of an array for magnetic source localization.


Subject(s)
Brain/diagnostic imaging , Magnetoencephalography/instrumentation , Optical Devices , Magnetics
14.
Article in English | MEDLINE | ID: mdl-19963909

ABSTRACT

A small (<1cm(3)), light-weight (<1g including batteries), low power (10mW, lasts 25 hrs), long range (22 ft.), 3-channel wireless neural recording system is designed, fabricated and characterized through in-vitro and in-vivo experiments. The transmitter comprises of an ASIC fabricated in 2-Poly, 2-Metal 1.5 microm AMIS process which can transmit data out wirelessly using on-chip VCO or low power commercial off-the-shelf (COTS) transmitters. The microsystem is employed in collecting neural signals from two different animal models: axons in cockroach leg and forelimb area of the motor cortex of a mature Long Evans rat.


Subject(s)
Microcomputers , Telemetry/instrumentation , Animals , Cockroaches/physiology , Femur/physiology , Motor Cortex/physiology , Nervous System Physiological Phenomena , Rats , Rats, Long-Evans
15.
Article in English | MEDLINE | ID: mdl-19965244

ABSTRACT

We describe a flexible wireless neural recording system, which is comprised of a 15-channel analog FM transmitter, digital receiver and custom user interface software for data acquisition. The analog front-end is constructed from commercial off the shelf (COTS) components and weighs 6.3g (including batteries) and is capable of transmitting over 24 hours up to a range over 3m with a 25microV(rms) in-vivo noise floor. The Software Defined Radio (SDR) and the acquisition software provide a data acquisition platform with real time data display and can be customized based on the specifications of various experiments. The described system was characterized with in-vitro and in-vivo experiments and the results are presented.


Subject(s)
Signal Processing, Computer-Assisted/instrumentation , Software , Telemetry/instrumentation , Algorithms , Animals , Callithrix , Computer Graphics/instrumentation , Computer Systems , Electric Power Supplies , Electrodes , Humans , Nerve Net , Rats , Telemetry/economics , Telemetry/methods , Transducers , User-Computer Interface
SELECTION OF CITATIONS
SEARCH DETAIL
...