1.
Nanoscale Adv ; 6(11): 2838-2849, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38817427

ABSTRACT

In this work, we report on studies of graphene exposed to tritium gas in a controlled environment. The single layer graphene on a SiO2/Si substrate was exposed to 400 mbar of T2, for a total time of ∼55 h. The resistivity of the graphene sample was measured in situ during tritium exposure using the van der Pauw method. We found that the sheet resistance increases by three orders of magnitude during the exposure, suggesting significant chemisorption of tritium. After exposure, the samples were characterised ex situ via spatio-chemical mapping with a confocal Raman microscope, to study the effect of tritium on the graphene structure (tritiation yielding T-graphene), as well as the homogeneity of modifications across the whole area of the graphene film. The Raman spectra after tritium exposure were comparable to previously observed results in hydrogen-loading experiments, carried out by other groups. By thermal annealing we also could demonstrate, using Raman spectral analysis, that the structural changes were largely reversible. Considering all observations, we conclude that the graphene film was at least partially tritiated during the tritium exposure, and that the graphene film by and large withstands the bombardment by electrons from the ß-decay of tritium, as well as by energetic primary and secondary ions.

2.
Sensors (Basel) ; 22(24)2022 Dec 19.
Article in English | MEDLINE | ID: mdl-36560382

ABSTRACT

Confocal Raman microscopic (CRM) imaging has evolved to become a key tool for spatially resolved, compositional analysis and imaging, down to the µm-scale, and nowadays one may choose between numerous commercial instruments. That notwithstanding, situations may arise which exclude the use of a commercial instrument, e.g., if the analysis involves toxic or radioactive samples/environments; one may not wish to render an expensive instrument unusable for other uses, due to contamination. Therefore, custom-designed CRM instrumentation-being adaptable to hazardous conditions and providing operational flexibility-may be beneficial. Here, we describe a CRM setup, which is constructed nearly in its entirety from off-the-shelf optomechanical and optical components. The original aim was to develop a CRM suitable for the investigation of samples exposed to tritium. For increased flexibility, the CRM system incorporates optical fiber coupling to both the Raman excitation laser and the spectrometer. Lateral raster scans and axial profiling of samples are facilitated by the use of a motorized xyz-translation assembly. Besides the description of the construction and alignment of the CRM system, we also provide (i) the experimental evaluation of system performance (such as, e.g., spatial resolution) and (ii) examples of Raman raster maps and axial profiles of selected thin-film samples (such as, e.g., graphene sheets).


Subject(s)
Optical Fibers , Spectrum Analysis, Raman , Microscopy, Confocal/methods , Spectrum Analysis, Raman/methods
3.
Sensors (Basel) ; 21(18)2021 Sep 14.
Article in English | MEDLINE | ID: mdl-34577377

ABSTRACT

Highly accurate, quantitative analyses of mixtures of hydrogen isotopologues-both the stable species, H2, D2, and HD, and the radioactive species, T2, HT, and DT-are of great importance in fields as diverse as deuterium-tritium fusion, neutrino mass measurements using tritium ß-decay, or for photonuclear experiments in which hydrogen-deuterium targets are used. In this publication we describe a production, handling, and analysis facility capable of fabricating well-defined gas samples, which may contain any of the stable and radioactive hydrogen isotopologues, with sub-percent accuracy for the relative species concentrations. The production is based on precise manometric gas mixing of H2, D2, and T2. The heteronuclear isotopologues HD, HT, and DT are generated via controlled, in-line catalytic reaction or by ß-induced self-equilibration, respectively. The analysis was carried out using an in-line intensity- and wavelength-calibrated Raman spectroscopy system. This allows for continuous monitoring of the composition of the circulating gas during the self-equilibration or catalytic evolution phases. During all procedures, effects, such as exchange reactions with wall materials, were considered with care. Together with measurement statistics, these and other systematic effects were included in the determination of composition uncertainties of the generated reference gas samples. Measurement and calibration accuracy at the level of 1% was achieved.


Subject(s)
Gases , Hydrogen , Calibration , Catalysis , Spectrum Analysis, Raman
4.
Sensors (Basel) ; 20(17)2020 Aug 26.
Article in English | MEDLINE | ID: mdl-32859049

ABSTRACT

The Karlsruhe Tritium Neutrino (KATRIN) experiment aims at measuring the effective electron neutrino mass with a sensitivity of 0.2 eV/c2, i.e., improving on previous measurements by an order of magnitude. Neutrino mass data taking with KATRIN commenced in early 2019, and after only a few weeks of data recording, analysis of these data showed the success of KATRIN, improving on the known neutrino mass limit by a factor of about two. This success very much could be ascribed to the fact that most of the system components met, or even surpassed, the required specifications during long-term operation. Here, we report on the performance of the laser Raman (LARA) monitoring system which provides continuous high-precision information on the gas composition injected into the experiment's windowless gaseous tritium source (WGTS), specifically on its isotopic purity of tritium-one of the key parameters required in the derivation of the electron neutrino mass. The concentrations cx for all six hydrogen isotopologues were monitored simultaneously, with a measurement precision for individual components of the order 10-3 or better throughout the complete KATRIN data taking campaigns to date. From these, the tritium purity, εT, is derived with precision of <10-3 and trueness of <3 × 10-3, being within and surpassing the actual requirements for KATRIN, respectively.

5.
Appl Spectrosc ; 67(8): 949-59, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23876734

ABSTRACT

An integrated concept for post-acquisition spectrum analysis was developed for in-line (real-time) and off-line applications that preserves absolute spectral quantification; after the initializing parameter setup, only minimal user intervention is required. This spectral evaluation suite is composed of a sequence of tasks specifically addressing cosmic ray removal, background subtraction, and peak analysis and fitting, together with the treatment of two-dimensional charge-coupled device array data. One may use any of the individual steps on their own, or may exclude steps from the chain if so desired. For the background treatment, the canonical rolling-circle filter (RCF) algorithm was adopted, but it was coupled with a Savitzky-Golay filtering step on the locus-array generated from a single RCF pass. This novel only-two-parameter procedure vastly improves on the RCF's deficiency to overestimate the baseline level in spectra with broad peak features. The peak analysis routine developed here is an only-two-parameter (amplitude and position) fitting algorithm that relies on numerical line shape profiles rather than on analytical functions. The overall analysis chain was programmed in National Instrument's LabVIEW; this software allows for easy incorporation of this spectrum analysis suite into any LabVIEW-managed instrument control, data-acquisition environment, or both. The strength of the individual tasks and the integrated program sequence are demonstrated for the analysis of a wide range of (although not necessarily limited to) Raman spectra of varying complexity and exhibiting nonanalytical line profiles. In comparison to other analysis algorithms and functions, our new approach for background subtraction, peak analysis, and fitting returned vastly improved quantitative results, even for "hidden" details in the spectra, in particular, for nonanalytical line profiles. All software is available for download.


Subject(s)
Cosmic Radiation , Spectrum Analysis, Raman/methods , Subtraction Technique , Automation , Automation, Laboratory , Biomedical Research/methods , Computer Simulation , Humans , Image Processing, Computer-Assisted , Reproducibility of Results , Signal Processing, Computer-Assisted
6.
Anal Chem ; 85(5): 2739-45, 2013 Mar 05.
Article in English | MEDLINE | ID: mdl-23320553

ABSTRACT

Highly accurate, in-line, and real-time composition measurements of gases are mandatory in many processing applications. The quantitative analysis of mixtures of hydrogen isotopologues (H2, D2, T2, HD, HT, and DT) is of high importance in such fields as DT fusion, neutrino mass measurements using tritium ß-decay or photonuclear experiments where HD targets are used. Raman spectroscopy is a favorable method for these tasks. In this publication we present a method for the in-line calibration of Raman systems for the nonradioactive hydrogen isotopologues. It is based on precise volumetric gas mixing of the homonuclear species H2/D2 and a controlled catalytic production of the heteronuclear species HD. Systematic effects like spurious exchange reactions with wall materials and others are considered with care during the procedure. A detailed discussion of statistical and systematic uncertainties is presented which finally yields a calibration accuracy of better than 0.4%.