Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 38(6): 362-369, nov.-dic. 2019. ilus, tab, graf
Article in Spanish | IBECS | ID: ibc-191700

ABSTRACT

OBJETIVO: El objetivo fue doble, valorar el acuerdo interobservador en la segmentación tumoral y la búsqueda de una metodología fiable y aplicable en la segmentación de gliomas usando PET/TC con 18F-fluorocolina. MATERIAL Y MÉTODOS: Se incluyeron 25 pacientes con glioma, procedentes de un estudio prospectivo no randomizado (Functional and Metabolic Glioma Analysis). Se analizó la variabilidad interobservador usando umbrales fijos. Diferentes estrategias se emplearon en la segmentación. Primero, se realizó una segmentación semiautomática, seleccionando el mejor umbral del SUVmáx-% para cada lesión. Posteriormente, se determinó una variable del SUVmáx-% dependiente del SUVmáx. Finalmente se realizó una segmentación usando un valor de umbral fijo de SUVmáx. Para ello, se realizó un muestreo de 10 regiones de interés (ROI de 2,8cm2) localizadas en cerebro normal. El valor superior obtenido de la media del muestreo+/-3 desviaciones estándar se usó como valor de corte. Todos los procedimientos fueron testados y clasificados como válidos o no en la segmentación tumoral en consenso por dos observadores. RESULTADOS: En la segmentación piloto, la media+/-DE del SUVmáx, SUVmedio y el umbral del SUVmáx-% fue de 3,64+/-1,77; 1,32+/-0,57 y 2,132+/-8,39, respectivamente. El valor óptimo del umbral SUVmáx-% mostró una asociación significativa con el SUVmáx (Pearson=-0,653; p = 0,002). Sin embargo, el modelo de regresión lineal del total de la muestra no fue bueno lo que justificó la división de la misma en dos grupos homogéneos, definiendo dos fórmulas para predecir el umbral del SUVmáx-%. Para el tercer procedimiento, el valor obtenido de la media SUVmáx+3 DE fue de 0,33. Este valor permitió segmentar correctamente una elevada proporción de casos, aunque no todos. CONCLUSIÓN: Se encontró una gran variabilidad interobservador en la segmentación tumoral. Ninguno de los métodos fue capaz de segmentar correctamente todos los gliomas probablemente debido a la amplia heterogeneidad en la PET/TC con 18F-fluorocolina


AIM: Our aim was two-fold, to study the interobserver agreement in tumour segmentation and to search for a reliable methodology to segment gliomas using 18F-fluorocholine PET/CT. METHODS: 25 patients with glioma, from a prospective and non-randomized study (Functional and Metabolic Glioma Analysis), were included. Interobserver variability in tumour segmentation was assessed using fixed thresholds. Different strategies were used to segment the tumours. First, a semi-automatic tumour segmentation was performed, selecting the best SUVmax-% threshold for each lesion. Next we determined a variable SUVmax-% depending on the SUVmax. Finally a segmentation using a fixed SUVmax threshold was performed. To do so, a sampling of 10 regions of interest (ROI of 2.8cm2) located in the normal brain was performed. The upper value of the sample mean SUVmax+/-3 SD was used as cut-off. All procedures were tested and classified as effective or not for tumour segmentation by two observer's consensus. RESULTS: In the pilot segmentation, the mean+/-SD of SUVmax, SUVmean and optimal SUVmax-% threshold were: 3.64+/-1.77, 1.32+/-0.57 and 21.32+/-8.39, respectively. Optimal SUVmax-% threshold showed a significant association with the SUVmax (Pearson=−0.653, p=.002). However, the linear regression model for the total sample was not good, that supported the division in two homogeneous groups, defining two formulas for predicting the optimal SUVmax-% threshold. As to the third procedure, the obtained value for the mean SUVmax background+3 SD was 0.33. This value allowed segmenting correctly a significant fraction of tumours, although not all. CONCLUSION: A great interobserver variability in the tumour segmentation was found. None of the methods was able to segment correctly all the gliomas, probably explained by the wide tumour heterogeneity on 18F-fluorocholine PET/CT


Subject(s)
Humans , Central Nervous System Neoplasms/diagnostic imaging , Central Nervous System Neoplasms/pathology , Fluorodeoxyglucose F18 , Glioma/diagnostic imaging , Glioma/pathology , Tomography, X-Ray Computed , Radiopharmaceuticals , Observer Variation , Positron-Emission Tomography , Tomography, X-Ray Computed/methods , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...