1.
Indoor Air ; 27(2): 303-310, 2017 03.
Article in English | MEDLINE | ID: mdl-27224645

ABSTRACT

We investigated the effect of weekends and school holidays on the daily frequency and severity of respiratory and other symptoms among children attending schools with (index) or without (reference) moisture damage in Spain, the Netherlands, and Finland. Throughout 1 year, parents of 419 children with a respiratory condition attending index (n=15) or reference (n=10) primary schools completed three symptom diaries. We assessed associations between lower respiratory tract, upper respiratory tract or allergy, and other symptom scores and school day, weekend, or summer holiday using mixed regression models stratified by country and moisture damage. We evaluated interactions between moisture damage and type of day. We combined country-specific estimates (incidence rate ratios [IRRs] and 95% confidence interval [CI]) in meta-analyses. Symptom scores were lower during weekends and holiday. Lower respiratory tract symptoms were statistically significantly less common during holiday with strongest effect in index schools (IRR=0.7; CI=0.6-0.8). Reporting of other symptoms was more reduced during holiday in index (IRR=0.6; CI=0.4-0.9) than in reference (IRR=0.95; CI=0.8-1.2) schools (interaction P<.01). In conclusion, symptoms were less frequent and/or severe during summer holiday and weekends. This pattern was stronger among children attending moisture-damaged schools, suggesting potential improvement in moisture damage-related symptoms during school breaks.


Subject(s)
Air Pollution, Indoor/adverse effects , Humidity/adverse effects , Respiratory Tract Diseases/epidemiology , Schools/statistics & numerical data , Child , Female , Finland/epidemiology , Humans , Male , Netherlands/epidemiology , Respiratory Tract Diseases/etiology , Seasons , Spain/epidemiology
2.
Indoor Air ; 24(2): 148-57, 2014 Apr.
Article in English | MEDLINE | ID: mdl-23927557

ABSTRACT

Indoor exposure to microbial agents is known to influence respiratory health. Besides home exposure, exposure in schools can affect respiratory health. In this study, we measured endotoxin in settled dust in primary schools in three European countries from three different geographical regions with different climates. Our aim was to characterize endotoxin levels in primary schools and evaluate associations with potential determinants. Endotoxin levels were repeatedly assessed in 23 schools in Spain (n = 7), the Netherlands (n = 10), and Finland (n = 6) using electrostatic dustfall collectors. In total, 645 measurements were taken in 237 classrooms. Endotoxin levels differed significantly between countries; Dutch schools had the highest levels, while Finnish schools showed the lowest levels. In each country, differences in endotoxin levels were observed between schools and over the sampling periods. Estimates improved after adjustment for sampling period. Factors affecting endotoxin levels in a school differed per country. In general, endotoxin levels were higher in lower grades and in classrooms with higher occupancy. School endotoxin levels may contribute significantly to total endotoxin exposure in children and teachers. As the correlation between the repeated measurements is reasonable, single endotoxin measurements form a reasonable basis for estimating annual endotoxin levels in schools.


Subject(s)
Dust/analysis , Endotoxins/analysis , Schools/statistics & numerical data , Europe
3.
Indoor Air ; 22(6): 457-66, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22404345

ABSTRACT

UNLABELLED: The aim of this study was to assess occurrence of dampness and mold in school buildings in three European countries (the Netherlands, Spain, and Finland), representing different climatic regions. An assessment was performed utilizing both questionnaires and on-site building investigations, and the agreement between these two methods was evaluated for validation purposes. On the basis of questionnaire data from a representative sample of schools, different types of moisture problems were reported in 24-47% of all school buildings at the time of the study. Most commonly reported was dampness in the Netherlands, moisture/water damage in Spain, and mold odor in Finland. Subsequently, 20-24 schools per country were selected for on-site inspections by trained staff. The overall agreement between the questionnaire and inspection data was good (kappa-value 0.62), however, with large differences (0.39-0.91) between countries. Extrapolating from the inspection data, the minimum estimates for prevalence of moisture problems in school buildings are 20% in the Netherlands, 41% in Spain, and 24% in Finland. In conclusion, moisture problems (such as moisture damage, dampness, and mold) are relatively common in schools. The occurrence and severity may vary across geographical areas, which can be partly explained by building characteristics. PRACTICAL IMPLICATIONS: On the basis of this study, the prevalence of verified moisture problems in school buildings was highest in Spain, but lower and similar in Finland and the Netherlands. Questionnaire-based surveys can be used to assess moisture problems in school buildings, but because of large variation in agreement with inspection data, the questionnaire needs to be validated by on-site inspections in a subsample of the surveyed buildings.


Subject(s)
Climate , Fungi , Humidity , Public Facilities/statistics & numerical data , Schools/statistics & numerical data , Europe , Surveys and Questionnaires