1.
Ultrasonics ; 44 Suppl 1: e705-10, 2006 Dec 22.
Article in English | MEDLINE | ID: mdl-16875709

ABSTRACT

In a preceding study a new technique to non-invasively measure the bladder volume on the basis of non-linear wave propagation was validated. It was shown that the harmonic level generated at the posterior bladder wall increases for larger bladder volumes. A dedicated transducer is needed to further verify and implement this approach. This transducer must be capable of both transmission of high-pressure waves at fundamental frequency and reception of up to the third harmonic. For this purpose, a multi-layer transducer was constructed using a single element PZT transducer for transmission and a PVDF top-layer for reception. To determine feasibility of the multi-layer concept for bladder volume measurements, and to ensure optimal performance, an equivalent mathematical model on the basis of KLM-circuit modeling was generated. This model was obtained in two subsequent steps. Firstly, the PZT transducer was modeled without PVDF-layer attached by means of matching the model with the measured electrical input impedance. It was validated using pulse-echo measurements. Secondly, the model was extended with the PVDF-layer. The total model was validated by considering the PVDF-layer as a hydrophone on the PZT transducer surface and comparing the measured and simulated PVDF responses on a wave transmitted by the PZT transducer. The obtained results indicated that a valid model for the multi-layer transducer was constructed. The model showed feasibility of the multi-layer concept for bladder volume measurements. It also allowed for further optimization with respect to electrical matching and transmit waveform. Additionally, the model demonstrated the effect of mechanical loading of the PVDF-layer on the PZT transducer.


Subject(s)
Image Interpretation, Computer-Assisted/instrumentation , Imaging, Three-Dimensional/instrumentation , Models, Theoretical , Transducers , Ultrasonography/instrumentation , Urinary Bladder/diagnostic imaging , Animals , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Humans , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Reproducibility of Results , Sensitivity and Specificity , Ultrasonography/methods
2.
J Acoust Soc Am ; 108(2): 827-35, 2000 Aug.
Article in English | MEDLINE | ID: mdl-10955650

ABSTRACT

The beam shape of a circular array transducer that is commonly used in intravascular ultrasound catheters was investigated in linear mode of operation. For this use, a simulation program which can simulate the radio frequency (rf)-response of a number of scatterers has been developed. The program is based on the impulse response method, which is implemented in the frequency domain. Due to the unusual geometry of the transducer, the far field gets peculiarly shaped for large apertures. Instead of having a far field with its maximum intensity in a single lobe on the acoustical axis, the far field splits up into a dual-lobe far field with maximum intensity in two lobes off the acoustical axis. A formula is derived that predicts the occurrence of these beam shapes.


Subject(s)
Coronary Vessels/physiology , Ultrasonics , Humans , Models, Biological , Transducers
3.
Ultrasonics ; 38(1-8): 363-8, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10829689

ABSTRACT

Coronary flow assessment can be useful for determining the hemodynamic severity of a stenosis and to evaluate the outcome of interventional therapy. We developed a method for measuring the transverse flow through the imaging plane of an intravascular ultrasound (IVUS) catheter. This possibility has raised great clinical interest since it permits simultaneous assessment of vessel geometry and function with the same device. Furthermore, it should give more accurate information than combination devices because lumen diameter and velocity are determined at the same location. Flow velocity is estimated based on decorrelation estimation from sequences of radiofrequency (RF) traces acquired at nearly the same position. Signal gating yields a local estimate of the velocity. Integrating the local velocity over the lumen gives the quantitative flow. This principle has been calibrated and tested through computer modeling, in vitro experiments using a flow phantom and in vivo experiments in a porcine animal model, and validated against a Doppler element containing guide wire (Flowire) in humans. Originally the method was developed and tested for a rotating single element device. Currently the method is being developed for an array system. The great advantage of an array over the single element approach would be that the transducer has no intrinsic motion. This intrinsic motion sets a minimal threshold in the detectable velocity components. Although the principle is the same, the method needs some adaptation through the inherent different beamforming of the transducer. In this paper various aspects of the development of IVUS flow are reviewed.


Subject(s)
Blood Flow Velocity , Catheterization , Coronary Vessels/diagnostic imaging , Animals , Computer Simulation , Hemodynamics , Phantoms, Imaging , Swine , Transducers , Ultrasonography