Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
J Assoc Off Anal Chem ; 67(2): 275-7, 1984.
Article in English | MEDLINE | ID: mdl-6725196

ABSTRACT

A method is described for the determination of pentachlorophenol (PCP) in gelatin. The method employs acid and heat to hydrolyze the gelatin matrix, a base partition and wash for separation and cleanup, and a reacidification and extraction with hexane for direct determination of PCP, without preparation of a derivative, using gas chromatography (GC) with a 1% SP- 124ODA liquid phase and a 63Ni electron capture detector. Recoveries averaged 106% for fortifications between 0.02 and 1.0 ppm. The limit of quantitation is 20 ppb. The limit of detection is 4-6 ppb. The method, which has undergone a successful intralaboratory trial, is simple and rapid, and requires only general laboratory reagents and equipment. GC of the acetate derivative of PCP is used for confirmation of identity.


Subject(s)
Chlorophenols/analysis , Gelatin/analysis , Pentachlorophenol/analysis , Chromatography, Gas/methods , Food Contamination , Pentachlorophenol/isolation & purification
5.
J Assoc Off Anal Chem ; 61(4): 877-83, 1978 Jul.
Article in English | MEDLINE | ID: mdl-79570

ABSTRACT

Finfish, shellfish, and crustacean samples are extracted with isopropanol and benzene; the extract is filtered and then concentrated. The extract, dissolved in hexane, is treated with oleum and extracted with aqueous alkali. The aqueous phase is acidified and extracted with petroleum ether-ethyl ether (1 + 1). The Kepone residue is determined by electron capture gas-liquid chromatography (GLC). Recoveries obtained by 8 laboratories from 15 species of finfish fortified at 0.02-0.23 ppm ranged from 37 to 107% with a mean +/- relative standard deviation of 79.4 +/- 14.5%. For oysters fortified at 0.01-0.10 ppm, recoveries range from 63 to 129% with a mean of 78.8 +/- 20.8%. For crustaceans fortified at 0.05-0.26 ppm, recoveries ranged from 52 to 110% with a mean of 78 +/- 16.4%. The approximate limits of quantitation for finfish and for shellfish and crustaceans are 0.02 and 0.05 ppm, respectively, under the GLC conditions used in this study.


Subject(s)
Chlordecone/analysis , Fishes , Insecticides/analysis , Pesticide Residues/analysis , Shellfish/analysis , Animals , Chromatography, Gas , Chromatography, Liquid , Fish Products/analysis
SELECTION OF CITATIONS
SEARCH DETAIL