ABSTRACT

BACKGROUND: Transvenous lead extraction (TLE) is now a first-line technique for the treatment of complications related to cardiac implantable electronic devices. The aim of the study was to demonstrate that it is possible to safely perform difficult TLE procedures with a maximum reduction of peri-procedural major complications. METHODS: A total of 1000 consecutive patients undergoing TLE in a single high-volume center from 2016 to 2019 were studied. All procedures were performed in a hybrid room or operating room by a specialized TLE team. TLE was performed under general anesthesia and monitored by transesophageal echocardiography, and the operating room was suitably equipped for immediate surgical intervention. The effectiveness and safety of the procedures were assessed, with particular emphasis on major complications. RESULTS: In all, 1952 leads with the mean implant duration of 111.7 ± 77.6 months had been extracted. Complete procedural success of patients was achieved in 95.9% and clinical success in 99.1%. Major complications, predominantly cardiac tamponade (63.3%), occurred in 22 patients (2.2%). Rapid diagnosis and immediate intervention were the key to a 100% survival in patients with this complication. CONCLUSION: Performing procedures in a hybrid operating room under general anesthesia in the presence of a cardiac surgeon and with the use of transesophageal echocardiography significantly improves the safety of transvenous lead extraction.


Subject(s)
Defibrillators, Implantable/adverse effects , Device Removal/methods , Pacemaker, Artificial/adverse effects , Tricuspid Valve/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Echocardiography , Female , Humans , Male , Middle Aged , Pregnancy , Retrospective Studies , Treatment Outcome , Universal Precautions
2.
Postepy Kardiol Interwencyjnej ; 15(3): 345-356, 2019.
Article in English | MEDLINE | ID: mdl-31592259

ABSTRACT

INTRODUCTION: Transvenous leads extraction (TLE) of permanently implanted coronary sinus (CS) leads is widely believed to present greater risks than the removal of other leads. AIM: To assess the safety and efficacy of CS leads extraction based on large research material obtained by one operator performing procedures in two TLE centres. MATERIAL AND METHODS: We extracted 408 CS leads from 389 patients, and the results were compared to a control group of 2465 patients who underwent non-CS lead TLE procedures. RESULTS: There were no significant differences in the clinical success rate (97.9% vs. 98.0%) or the major complication rate (2.1% vs. 1.8%) between the CS and control group. CS lead destination (LV/LA pacing) and tip location (CS ostium/mid CS /CS tributaries) influenced the procedural and radiological success rates and procedural complexity but not the complications. CS lead extraction did not affect the necessity for a cardiosurgical intervention or presence of procedure-related death. CONCLUSIONS: TLE of CS leads can be achieved with a high procedural success rate. The major complication rate is not higher than that seen in non-CS lead extraction patients. More than half of CS leads cannot be removed by simple traction and the use of mechanical sheaths may be necessary. The detachment of CS leads from connective tissue scars in the venous and atrial areas up to the CS ostium is generally sufficient for further removal of the lead using simple traction.