Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Ann Vasc Surg ; 103: 141-150, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38395344

ABSTRACT

BACKGROUND: The aim of the study is to compare the short-term and medium-term outcomes in patients who underwent open repair (OR) or endovascular repair (ER) for peripheral arterial disease (PAD) also including stratifications based on severity and year of the first intervention. METHODS: We conducted an observational retrospective single-center cohort study. We evaluated patients with PAD that primarily underwent ER, OR, minor, and major amputations in a single center from 2005 to 2020. The patients were then subdivided according to the type of intervention (OR versus ER), and stratified according to the International Classification of Diseases 9 code reported in the operating documents and to the year intervention. Mortality, minor, and major amputation rates occurring at 30 days, 2 years, and 5 years after the first intervention were evaluated as primary outcomes and compared between patient groups in both stratifications. Moreover, Kaplan-Maier curves were analyzed for these outcomes. RESULTS: One thousand four hundred ninety two patients (67.0% males) with PAD were evaluated. Their clinical presentations were intermittent claudication in 51.4% of cases, rest pain in 16.8%, ulcers in 10.3%, and gangrene in 21.5%. Nine hundred ninety seven (66.8%) underwent OR and 495 (33.2%) ER as first intervention for PAD. No statistical differences were observed in terms of mortality in the 2 groups (OR versus ER, P = 1,000, P = 0.357, and P = 0.688 at 30 days, 2 years, and 5 years, respectively). The rate of minor amputations was significantly higher (P < 0.012, P < 0.002, and P < 0.007 at 30 days, 2 years, and 5 years, respectively) for ER group in any of the observed follow-up periods. Also, we have observed that OR and ER do not have any significant short-term and medium-term major amputation rate differences. CONCLUSIONS: In our experience, the impact of ER does not significantly change short-term and mid-term major outcomes in patients with PAD.


Subject(s)
Amputation, Surgical , Endovascular Procedures , Limb Salvage , Peripheral Arterial Disease , Humans , Peripheral Arterial Disease/mortality , Peripheral Arterial Disease/surgery , Peripheral Arterial Disease/diagnosis , Retrospective Studies , Female , Male , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Aged , Time Factors , Treatment Outcome , Middle Aged , Risk Factors , Aged, 80 and over , Risk Assessment
2.
J Digit Imaging ; 36(5): 2125-2137, 2023 10.
Article in English | MEDLINE | ID: mdl-37407843

ABSTRACT

The aim of our study is to validate a totally automated deep learning (DL)-based segmentation pipeline to screen abdominal aortic aneurysms (AAA) in computed tomography angiography (CTA) scans. We retrospectively evaluated 73 thoraco-abdominal CTAs (48 AAA and 25 control CTA) by means of a DL-based segmentation pipeline built on a 2.5D convolutional neural network (CNN) architecture to segment lumen and thrombus of the aorta. The maximum aortic diameter of the abdominal tract was compared using a threshold value (30 mm). Blinded manual measurements from a radiologist were done in order to create a true comparison. The screening pipeline was tested on 48 patients with aneurysm and 25 without aneurysm. The average diameter manually measured was 51.1 ± 14.4 mm for patients with aneurysms and 21.7 ± 3.6 mm for patients without aneurysms. The pipeline correctly classified 47 AAA out of 48 and 24 control patients out of 25 with 97% accuracy, 98% sensitivity, and 96% specificity. The automated pipeline of aneurysm measurements in the abdominal tract reported a median error with regard to the maximum abdominal diameter measurement of 1.3 mm. Our approach allowed for the maximum diameter of 51.2 ± 14.3 mm in patients with aneurysm and 22.0 ± 4.0 mm in patients without an aneurysm. The DL-based screening for AAA is a feasible and accurate method, calling for further validation using a larger pool of diagnostic images towards its clinical use.


Subject(s)
Aortic Aneurysm, Abdominal , Computed Tomography Angiography , Humans , Computed Tomography Angiography/methods , Artificial Intelligence , Retrospective Studies , Aortic Aneurysm, Abdominal/diagnostic imaging , Tomography, X-Ray Computed
3.
Eur J Clin Invest ; 53(9): e14011, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37099603

ABSTRACT

BACKGROUND: This study aimed to estimate if the altered sphygmic wave transmission may affect the left ventricular (LV) contractile function in patients undergoing endovascular aortic repair (EVAR). METHODS: A prospective single-centre study was carried out on consecutive patients undergoing EVAR for abdominal aortic aneurysm. A preoperative and 6-month single photon emission computed tomography (SPECT) with arterial stiffness measurement were performed to evaluate variations in pressure wave curve and myocardial perfusion parameters. RESULTS: From 2018 to 2020 a total of 16 patients were included in the study. Among the parameters evaluated, we found a measurable reduction of the reflected wave transit time from pre- to postoperative period, for both stress (115.13 ± 7.2 ms-111.1 ± 7.0 ms, p = .08) and rest SPECT acquisitions (115.3 ± 6.2 ms-112.2 ± 5.6 ms, p = .1). Unidirectional increase of both LV end-systolic volume (34 ± 9 mL-39 ± 8 mL, p = .02) and end-diastolic volume (85 ± 34 mL-89 ± 29 mL, p = .6) was also observed. Lastly, the ratio between the end-systolic pressure and the end-systolic volume (maximal systolic myocardial stiffness) decreased from 3.6 ± 1.5 mmHg/mL to 2.66 ± .74 mmHg/mL (p = .03). CONCLUSIONS: Our data showed that EVAR induced an altered transmission of the sphygmic wave associated with an early LV contractile impairment.


Subject(s)
Aortic Aneurysm, Abdominal , Ventricular Dysfunction, Left , Humans , Prospective Studies , Endovascular Aneurysm Repair , Ventricular Function, Left , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery
4.
J Endovasc Ther ; 28(3): 407-414, 2021 06.
Article in English | MEDLINE | ID: mdl-33660576

ABSTRACT

OBJECTIVES: Aim of this work was to investigate precision of deployment and conformability of a new generation GORE EXCLUDER Conformable Endoprosthesis with active control system (CEXC Device, W.L. Gore and Associates, Flagstaff, AZ, USA) by analyzing aortic neck coverage and curvature. METHODS: All consecutive elective patients affected by abdominal aortic aneurysm or aortoiliac aneurysm treated at our institution between November 2018 and June 2019 with the new CEXC Device were enrolled. Validated software was adopted to determine the available apposition surface area into the aortic neck, apposition of the endograft to the aortic wall, shortest apposition length (SAL), shortest distance between the endograft fabric and the lowest renal arteries (SFD) and between the endograft fabric and the contralateral renal artery (CFD). Pointwise centerline curvature was also computed. RESULTS: Twelve patients (10 men, median age 78 years (71.75, 81.0)) with available pre- and postoperative computed tomography angiography (CTA) were included. Technical success was obtained in all the cases. Preoperative median length of the proximal aortic neck was 16.1 mm (10.7, 21.7) and suprarenal (α) and infrarenal (ß) neck angulation were, respectively, 28.9° (15.7°, 47.5°) and 75.0° (66.9°, 81.4°). Postoperative median apposition surface coverage was 79% (69.25%, 90.75%) of the available apposition surface. SFD and CFD were 1.5 mm (0.75, 5.25) and 7 mm (4.5, 21.5), respectively. Average curvature over the infrarenal aorta decreased from 25 m-1 (21.75, 29.0) to 22.5 m-1 (18.75, 24.5) postoperatively (p=0.02). Maximum curvature did not decrease significantly from 64.5 m-1 (54.25, 92.0) to 62 m-1 (41.75, 71.5) (p=0.1). CONCLUSIONS: Our early experience showed that deployment of the CEXC Device is safe and effective for patients with challenging proximal aortic necks. Absence of significant changes between pre- and postoperative proximal aortic neck angulations and curvature confirms the high conformability of this endograft.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortography , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Male , Prosthesis Design , Retrospective Studies , Time Factors , Treatment Outcome
5.
Ann Vasc Surg ; 74: 73-79, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33549797

ABSTRACT

BACKGROUND: The aim of the study is to evaluate the impact of COVID-19 pandemic on vascular surgery practice in a regional hub center for complex vascular disease. METHODS: This is an observational single-center study in which we collected clinical and surgical data during (P1) and after (P2) the COVID-19 outbreak and the lockdown measures implemented in Northern Italy. We compared those data with the two-month period before the pandemic (P0). RESULTS: Compared to P0, ambulatory activities were severely reduced during P1 and limited to hospitalized patients and outpatients with urgent criteria. We performed 61 operations (18 urgent and 43 elective), with a decrease in both aortic (-17.8%), cerebrovascular (-53.3%), and peripheral artery (-42.6%) disease treatments. We also observed a greater drop in open procedures (-53.2%) than in endovascular ones (-22%). All the elective patients were treated for notdeferrable conditions and they were COVID-19 negative at the ward admission screening; despite this one of them developed COVID19 during the hospital stay. Four COVID-19 positive patients were treated in urgent setting for acute limb ischemia. Throughout P2 we gradually rescheduled elective ambulatory (+155.5%) and surgical (+18%) activities, while remaining substantially lower than during P0 (respectively -45.6% and -25.7%). CONCLUSIONS: Despite COVID-19 pandemic, our experience shows that with careful patient's selection, dedicated prehospitalization protocol and proper use of personal protective equipment it is possible to guarantee continuity of care.


Subject(s)
Academic Medical Centers/trends , COVID-19 , Practice Patterns, Physicians'/trends , Surgeons/trends , Vascular Surgical Procedures/trends , Aged , Aged, 80 and over , Clinical Decision-Making , Continuity of Patient Care/trends , Female , Humans , Italy , Male , Middle Aged , Patient Selection , Regional Health Planning/trends , Retrospective Studies , Time Factors
SELECTION OF CITATIONS