1.
Med Microbiol Immunol ; 197(1): 55-64, 2008 Mar.
Article in English | MEDLINE | ID: mdl-17899185

ABSTRACT

In a multicenter study a new, fully automated Roche Diagnostics Elecsys HBsAg II screening assay with improved sensitivity to HBsAg mutant detection was compared to well-established HBsAg tests: AxSYM HBsAg V2 (Abbott), Architect HBsAg (Abbott), Advia Centaur HBsAg (Bayer) Enzygnost HBsAg 5.0 (Dade-Behring), and Vitros Eci HBsAg (Ortho). A total of 16 seroconversion panels, samples of 60 HBsAg native mutants, and 31 HBsAg recombinant mutants, dilution series of NIBSC and PEI standards, 156 HBV positive samples comprising genotypes A to G, 686 preselected HBsAg positive samples from different stages of infection, 3,593 samples from daily routine, and 6,360 unselected blood donations were tested to evaluate the analytical and clinical sensitivity, the detection of mutants, and the specificity of the new assay. Elecsys HBsAg II showed a statistically significant better sensitivity in seroconversion panels to the compared tests. Fifty-seven out of 60 native mutants and all recombinant mutants were found positive. Among 156 HBV samples with different genotypes and 696 preselected HBsAg positive samples Elecsys HBsAg II achieved a sensitivity of 100%. The lower detection limit for NIBSC standard was calculated to be 0.025 IU/ml and for the PEI standards ad and ay it was <0.001 and <0.005 U/ml, respectively. Within 2,724 daily routine specimens and 6.360 unselected blood donations Elecsys HBsAg II showed a specificity of 99.97 and 99.88%, respectively. In conclusion the new Elecsys HBsAg II shows a high sensitivity for the detection of all stages of HBV infection and HBsAg mutants paired together with a high specificity in blood donors, daily routine samples, and potentially interfering sera.


Subject(s)
Blood Donors , Hepatitis B Surface Antigens/blood , Hepatitis B virus/genetics , Hepatitis B, Chronic/diagnosis , Automation , Genotype , Humans , Immunosorbent Techniques/standards , Sensitivity and Specificity
2.
Clin Lab ; 52(9-10): 463-73, 2006.
Article in English | MEDLINE | ID: mdl-17078473

ABSTRACT

Fourth-generation screening assays which permit a simultaneous detection of human immunodeficiency virus (HIV) antigen and antibody reduce the diagnostic window on average by four days in comparison to third-generation antibody assays. Recently, the new automated Elecsys HIV combi was compared in a multicenter study to alternative fourth- and third-generation assays, p24 antigen test and HIV-1 RNA RT-PCR. A total of 104 serocon-version panels, samples of the acute phase of infection after seroconversion (n = 33), anti-HIV-1 positive specimens (n = 572) from patients in different stages of the disease, 535 subtyped samples from different geographical locations, including group M (subtypes A-J) and group O, anti-HIV-2 positive sera (n = 364), dilutions of cell culture supernatants (n = 60) infected with different HIV-1 subtypes, selected performance panels, 8406 unselected samples from blood donors originating from different blood transfusion centers, 3810 unselected sera from daily routine and from hospitalized patients, 9927 unselected samples from South Africa and 1943 potentially interfering samples were tested with the Elecsys HIV combi. Elecsys HIV combi showed a comparable sensitivity to HIV-1 Ag stand-alone assays for early detection of HIV infection in seroconversion panels. The mean time delay of Elecsys HIV combi (last negative sample + 1 day) in comparison to HIV-1 RT-PCR for 92 panels tested with both methods was 3.23 days. The diagnostic window was reduced with Elecsys HIV combi between 1.56 and 5.32 days in comparison to third-generation assays. The specificity of Elecsys HIV combi in blood donors was 99.80% after repeated testing. Our results show that a fourth-generation assay with improved specificity and sensitivity like the Elecsys HIV combi is suitable for blood donor screening due to its low number of false positives and since it detects HIV p24 antigen with a comparable sensitivity to single antigen assays.


Subject(s)
HIV Antibodies/blood , HIV Core Protein p24/blood , HIV Infections/diagnosis , HIV-1/isolation & purification , HIV-2/isolation & purification , Immunoassay , Early Diagnosis , Humans , RNA, Viral/analysis , Reverse Transcriptase Polymerase Chain Reaction , Sensitivity and Specificity
3.
J Virol Methods ; 78(1-2): 61-70, 1999 Mar.
Article in English | MEDLINE | ID: mdl-10204697

ABSTRACT

Although human immunodeficiency virus (HIV) antigen assays are of limited value for monitoring antiretroviral therapy, they play an important role for confirmatory testing of fourth generation HIV screening enzyme immunoassay (EIA) reactive samples. In a multicenter study, a new automated rapid p24 antigen assay, Elecsys HIV Ag (Roche Diagnostics Boehringer Mannheim GmbH, Penzberg, Germany), was compared to FDA licensed tests (Abbott HIV-1 Ag monoclonal and Coulter HIV-1 p24 antigen assay). In the evaluation 27 seroconversion panels were included, sera from the acute phase of infection, single and follow-up samples from HIV antibody positive patients, dilution series of HIV antigen positive standards, sera and cell culture supernatants infected with different HIV-1 subtypes (A-H, and O) HIV-2 and recombinant HIV-1 (gag/env) isolates. To challenge the specificity of the new assay, 2565 unselected blood donors, sera from pregnant women, dialysis and hospitalized patients and 407 potentially cross-reactive samples were investigated. Acute HIV infection was detected in three to eight seroconversion panels earlier with Elecsys HIV Ag than with the alternative assays. Higher numbers of serum samples from HIV infected patients tested positive by Elecsys HIV Ag than with the comparative assays. All HIV-1 subtypes and HIV-2 isolates were recognized with Elecsys HIV Ag. Abbott HIV-1 Ag monoclonal and Coulter HIV-1 p24 antigen assay showed a variable sensitivity for the different HIV-1 subtypes. The specificity of Elecsys HIV Ag and Coulter HIV-1 p24 antigen assay were 99.8 and 99.93%, respectively. All the eight sera that were false reactive by Elecsys HIV Ag were tested negative with the Elecsys HIV Ag Neutralization Test. In conclusion, Elecsys HIV Ag was more sensitive than the alternative assays and showed a high specificity in combination with the neutralization assay. The very short incubation time of 18 min and the fully automated procedure of Elecsys HIV Ag which permits direct testing from the primary patient blood collection tube, represent a major improvement for routine laboratory diagnosis in comparison to the alternative assays.


Subject(s)
HIV Core Protein p24/blood , HIV Infections/diagnosis , HIV-1/isolation & purification , Immunoassay/methods , Antibodies, Monoclonal/immunology , Evaluation Studies as Topic , Female , HIV Infections/virology , Humans , Neutralization Tests , Pregnancy , RNA, Viral/analysis , Reagent Kits, Diagnostic , Reverse Transcriptase Polymerase Chain Reaction , Sensitivity and Specificity
4.
J Virol Methods ; 75(1): 27-38, 1998 Nov.
Article in English | MEDLINE | ID: mdl-9820572

ABSTRACT

In order to reduce the window phase between time of human immunodeficiency virus (HIV) infection and laboratory diagnosis, new fourth generation screening assays which permit a simultaneous detection of HIV antigen and antibody have been developed. In a multicenter study, a new automated fourth generation assay, Enzymun-Test HIV Combi (Boehringer Mannheim GmbH) was compared to third generation assay, p24 antigen tests and Western blot. A total of 37 seroconversion panels, samples of the early infection (n = 42), HIV-1 antibody positive sera, including subtypes A E, and O (n = 1118), HIV-2 positive samples (n = 252) and cell culture supernatants infected with different HIV-1 subtypes and HIV-2 (n = 50), blood donors (n = 6649), hospitalized patients (n = 475), HIV neg. sera with indeterminate Western blot (n = 32), potentially cross reactive serum samples (n = 435) and HIV negative specimens from Cameroon (n = 68) were tested. A total of 16 of 29 seroconversions were detected on average 8.5 days earlier with Enzymun-Test HIV Combi than HIV-1/HIV-2 3rd generation EIA (Abbott Laboratories). Overall, in the 29 panels investigated comparatively with the two assays, the mean time delay between Enzymun-Test HIV Combi and HIV-1/HIV-2 3rd generation EIA was 4.7 days. HIV antigen was detected in three out of 35 seroconversions one bleed earlier with HIV-1 Ag Monoclonal than with Enzymun-Test HIV Combi. Enzymun-Test HIV Combi showed a sensitivity of 100% for HIV antibody detection for HIV-1 group M and O and HIV-2 positive specimens. While p24 antigen of different HIV-1 subtypes was detected with Enzymun-Test HIV Combi in all the 49 cell culture supernatants, HIV Ag was not detected in an HIV-2 virus lysate. A total of 66 false positive results out of 7659 HIV negative samples were obtained with the Enzymun-Test HIV Combi. The specificity for unselected blood donors was 99.6%. The Enzymun-Test HIV Combi permits an earlier diagnosis of HIV infection than third generation assays through the detection of p24 antigen, which may be present in serum samples from individuals with recent HIV infection prior to seroconversion and it shows an excellent sensitivity for antibodies to all known HIV-1 subtypes and HIV-2. The specificity in blood donors and hospitalized patients is comparable to that of other assays.


Subject(s)
HIV Antibodies/immunology , HIV Core Protein p24/blood , HIV Infections/diagnosis , HIV-1/immunology , HIV-2/immunology , Immunoenzyme Techniques , HIV Core Protein p24/genetics , HIV Core Protein p24/immunology , HIV Infections/blood , HIV Infections/immunology , HIV Infections/virology , HIV-1/genetics , HIV-2/genetics , Humans , Reagent Kits, Diagnostic , Time Factors
5.
Intervirology ; 41(1): 17-23, 1998.
Article in English | MEDLINE | ID: mdl-9705561

ABSTRACT

The new automated Enzymun-Test anti-HBc Plus for the detection of antibodies to hepatitis B virus (HBV) core antigen (anti-HBc) after pretreatment with reducing agents dithiothreitol (25 degrees C; + DTT) or potassium bisulfite (37 degrees C; + MBS) was evaluated by testing 571 serum and plasma samples. The panel included dilution series of reference standards and samples from chronic carriers, one seroconversion panel, samples from patients in acute or chronic stage of the disease or resolved hepatitis B, preselected sera from blood donors that were initially reactive in an anti-HBc assay without pretreatment, potentially cross-reactive serum samples obtained from patients suffering from other diseases or with passed infections other than HBV, pregnant women and individuals with HBV vaccination. The IMx CORE(TM) (Abbott Diagnostics) served as reference assay. Discrepant samples were further investigated with two different commercial anti-HBc enzyme immunoassays, other HBV-specific serological markers and HBV DNA hybridization. The sensitivity of the Enzymun-Test Anti-HBc Plus (25 degrees + DTT, and 37 degrees C; + MBS) in comparison to the reference assay was 100%. The IMx CORE showed a twofold higher sensitivity than Enzymun-Test Anti-HBc Plus for anti-HBc detection in dilution series of serum samples from HBV carriers. The agreement in terms of specificity of the Enzymun-Test Anti-HBc Plus (25 degrees C; + DTT, and 37 degrees C; + MBS) and in comparison to IMx CORE was 97.4 and 96.4%, respectively. After resolution of discrepant results (3 samples were tested false negative with IMx CORE), the agreement in terms of specificity of the Enzymun-Test Anti-HBc Plus (25 degrees C; + DTT, and 37 degrees C; + MBS) in comparison to the combination of the comparative assays was 98.3 and 97.4%, respectively. In conclusion, the new automated Enzymun-Test Anti-HBc Plus with sample pretreatment with DTT (25 degrees C; + DTT) or MBS (37 degrees C; + MBS) permits a highly sensitive and specific detection of anti-HBc in diagnostic virology and blood donation testing.


Subject(s)
Hepatitis B Antibodies/blood , Hepatitis B Core Antigens/immunology , Humans , Reproducibility of Results , Sensitivity and Specificity
6.
Buenos Aires; Coni; 1920. 196 p. ilus. (83732).
Monography in Spanish | BINACIS | ID: bin-83732
7.
Buenos Aires; Coni; 1920. 196 p. ilus.
Monography in Spanish | BINACIS | ID: biblio-1205678