Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Monit Assess ; 195(7): 845, 2023 Jun 15.
Article in English | MEDLINE | ID: mdl-37318651

ABSTRACT

An effective micro-level air quality management plan requires high-resolution monitoring of pollutants. India has already developed a vast network of air quality monitoring stations, both manual and real time, located primarily in urban areas, including megacities. The air quality monitoring network consists of conventional manual stations and real time Continuous Ambient Air Quality Monitoring Stations (CAAQMS) which comprise state-of-the-art analysers and instruments. India is currently in the early stages of developing and adopting economical portable sensor (EPS) in air quality monitoring systems. Protocols need to be established for field calibration and testing. The present research work is an attempt to develop a performance-based assessment framework for the selection of EPS for air quality monitoring. The two-stage selection protocol includes a review of the factory calibration data and a comparison of EPS data with a reference monitor, i.e. a portable calibrated monitor and a CAAQMS. Methods deployed include calculation of central tendency, dispersion around a central value, calculation of statistical parameters for data comparison, and plotting pollution rose and diurnal profile (peak and non-peak pollution measurement). Four commercially available EPS were tested blind, out of which, data from EPS 2 (S2) and EPS 3 (S3) were closer to reference stations at both locations. The selection was made by evaluating monitoring results, physical features, measurement range, and frequency along with examining capital cost. This proposed approach can be used to increase the usability of EPS in the development of micro-level air quality management strategies, other than regulatory compliance. For regulatory compliance, additional research is needed, including field calibration and evaluating EPS performance through additional variables. This proposed framework may be used as starting point, for such experiments, in order to develop confidence in the use of EPS.


Subject(s)
Air Pollutants , Air Pollution , Environmental Pollutants , Air Pollutants/analysis , Environmental Monitoring/methods , Air Pollution/analysis , Calibration , Particulate Matter/analysis , Review Literature as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...