Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Interv Radiol ; 35(3): 362-369, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38123126

ABSTRACT

PURPOSE: To determine time to occlusion and procedure costs of embolization of pulmonary arteriovenous malformations (PAVMs) using a polytetrafluoroethylene-covered microplug compared with embolization using detachable coils. MATERIALS AND METHODS: In this prospective study, 37 patients (mean age, 39.1 years [SD ± 17.6]) with 82 PAVMs underwent embolization with microplug or detachable coils between April 2019 and January 2023. Technical success, procedure time intervals, and costs were analyzed. RESULTS: In 37 patients, 82 PAVMs and 101 feeding arteries were successfully treated (microplug, 64; microplug + another device, 5; detachable coils alone, 32). Time from embolic device inserted into the catheter to device deployed and time to occlusion differed significantly between microplug and detachable coil cohorts (P < .0001 for both). Embolization with ≥1 microplug had a significantly shorter occlusion time than embolization with detachable coils (median, 10.0 minutes saved per feeding artery) (P < .0001). Compared with detachable coil embolization, microplug embolization saved a median of 9.0 minutes per feeding artery (P < .0001) and reduced room cost by a median of $429 per feeding artery (P < .0001). Device costs per feeding artery did not differ significantly between microplug ($2,790) and detachable coil embolization ($3,147) (P = .87). CONCLUSIONS: Compared with coils, microplugs had an equally high technical success rate but significant time to occlusion and room costs savings per feeding artery. Total room cost and device cost together did not differ significantly between microplugs and coils. Microplugs may be considered technically effective and at least cost-neutral for PAVM embolization where clinically appropriate.


Subject(s)
Arteriovenous Fistula , Arteriovenous Malformations , Embolization, Therapeutic , Pulmonary Artery/abnormalities , Pulmonary Veins , Pulmonary Veins/abnormalities , Humans , Adult , Prospective Studies , Polytetrafluoroethylene , Arteriovenous Malformations/diagnostic imaging , Arteriovenous Malformations/therapy , Arteriovenous Fistula/therapy , Embolization, Therapeutic/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Veins/diagnostic imaging , Treatment Outcome
2.
Contemp Clin Trials Commun ; 15: 100392, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31245651

ABSTRACT

Cocaine use in clinical trials is often measured via self-report, which can be inaccurate, or urine drug screens, which can be intrusive and burdensome. Devices that can automatically detect cocaine use and can be worn conveniently in daily life may provide several benefits. AutoSense is a wearable, physiological-monitoring suite that can detect cocaine use, but it may be limited as a method for monitoring cocaine use because it requires wearing a chestband with electrodes. This paper describes the design, rationale, and methodology of a project that seeks to build upon and extend previous work in the development of methods to detect cocaine use via wearable, unobtrusive mobile sensor technologies. To this end, a wrist-worn sensor suite (i.e., MotionSense HRV) will be developed and evaluated. Participants who use cocaine (N = 25) will be asked to wear MotionSense HRV and AutoSense for two weeks during waking hours. Drug use will be assessed via thrice-weekly urine drug screens and self-reports, and will be used to isolate periods of cocaine use that will be differentiated from other drug use. The present study will provide information on the feasibility and acceptability of using a wrist-worn device to detect cocaine use.

SELECTION OF CITATIONS
SEARCH DETAIL
...