1.
Medicina (Kaunas) ; 59(11)2023 Nov 07.
Article in English | MEDLINE | ID: mdl-38004013

ABSTRACT

Background and Objectives: Herein we used numerical analysis to study different biomechanical behaviors of mandibular bone subjected to 0.6 N, 1.2 N, and 2.4 N orthodontic loads during 0-8 mm periodontal breakdown using the Tresca failure criterion. Additionally, correlations with earlier FEA reports found potential ischemic and resorptive risks. Materials and Methods: Eighty-one models (nine patients) and 243 simulations (intrusion, extrusion, rotation, tipping, and translation) were analyzed. Results: Intrusion and extrusion displayed after 4 mm bone loss showed extended stress display in the apical and middle third alveolar sockets, showing higher ischemic and resorptive risks for 0.6 N. Rotation, translation, and tipping displayed the highest stress amounts, and cervical-third stress with higher ischemic and resorptive risks after 4 mm loss for 0.6 N. Conclusions: Quantitatively, rotation, translation, and tipping are the most stressful movements. All three applied forces produced similar stress-display areas for all movements and bone levels. The stress doubled for 1.2 N and quadrupled for 2.4 N when compared with 0.6 N. The differences between the three loads consisted of the stress amounts displayed in color-coded areas, while their location and extension remained constant. Since the MHP was exceeded, a reduction in the applied force to under 0.6 N (after 4 mm of bone loss) is recommended for reducing ischemic and resorptive risks. The stress-display pattern correlated with horizontal periodontal-breakdown simulations.


Subject(s)
Cancellous Bone , Tooth Movement Techniques , Humans , Tooth Movement Techniques/adverse effects , Computer Simulation , Finite Element Analysis , Periodontal Ligament
2.
Healthcare (Basel) ; 11(19)2023 Sep 25.
Article in English | MEDLINE | ID: mdl-37830659

ABSTRACT

This finite elements analysis (FEA) assessed the accuracy of maximum shear stress criteria (Tresca) in the study of orthodontic internal surface resorption and the absorption-dissipation ability of dental tissues. The present study was conducted over eighty-one models totaling 324 simulations with various bone loss levels (0-8 mm), where 0.6 N and 1.2 N were applied in the intrusion, extrusion, rotation, tipping, and translation movements. Tresca criteria displayed localized high-stress areas prone to resorption for all situations, better visible in the dentine component. The internal resorptive risks are less than external ones, seeming to increase with the progression of the periodontal breakdown, especially after 4 mm. The internal and external surface high-stress areas are strictly correlated. The qualitative stress display for both forces was almost similar. The rotation and tipping displayed the highest resorptive risks for the pulp chamber, decreasing with bone loss. The resorptive risks seem to increase along with the progression of periodontal breakdown if the same applied force is kept. The dentine resemblance to ductile based on its high absorption-dissipation ability seems correct. Tresca seems to supply a better predictability of the prone-to-resorption areas than the other failure criteria.

3.
Medicina (Kaunas) ; 59(8)2023 Aug 15.
Article in English | MEDLINE | ID: mdl-37629752

ABSTRACT

Background and Objectives: This numerical analysis investigated the biomechanical behavior of the mandibular bone as a structure subjected to 0.5 N of orthodontic force during periodontal breakdown. Additionally, the suitability of the five most used failure criteria (Von Mises (VM), Tresca (T), maximum principal (S1), minimum principal (S3), and hydrostatic pressure (HP)) for the study of bone was assessed, and a single criterion was identified for the study of teeth and the surrounding periodontium (by performing correlations with other FEA studies). Materials and Methods: The finite element analysis (FEA) employed 405 simulations over eighty-one mandibular models with variable levels of bone loss (0-8 mm) and five orthodontic movements (intrusion, extrusion, tipping, rotation, and translation). For the numerical analysis of bone, the ductile failure criteria are suitable (T and VM are adequate for the study of bone), with Tresca being more suited. S1, S3, and HP criteria, due to their distinctive design dedicated to brittle materials and liquids/gas, only occasionally correctly described the bone stress distribution. Results: Only T and VM displayed a coherent and correlated gradual stress increase pattern for all five movements and levels of the periodontal breakdown. The quantitative values provided by T and VM were the highest (for each movement and level of bone loss) among all five criteria. The MHP (maximum physiological hydrostatic pressure) was exceeded in all simulations since the mandibular bone is anatomically less vascularized, and the ischemic risks are reduced. Only T and VM displayed a correlated (both qualitative and quantitative) stress increase for all five movements. Both T and VM displayed rotation and translation, closely followed by tipping, as stressful movements, while intrusion and extrusion were less stressful for the mandibular bone. Conclusions: Based on correlations with earlier numerical studies on the same models and boundary conditions, T seems better suited as a single unitary failure criterion for the study of teeth and the surrounding periodontium.


Subject(s)
Bone Diseases, Metabolic , Cancellous Bone , Humans , Finite Element Analysis , Periodontal Ligament , Mandible
4.
Healthcare (Basel) ; 11(10)2023 May 16.
Article in English | MEDLINE | ID: mdl-37239733

ABSTRACT

This Finite Elements Analysis (FEA) assessed the accuracy of Tresca failure criteria (maximum shear stress) for the study of external root resorption. Additionally, the tooth absorption-dissipation ability was assessed. Overall, 81 models of the second mandibular premolar, out of a total of 324 simulations, were involved. Five orthodontic movements (intrusion, extrusion, rotation, translation, and tipping) were simulated under 0.6 N and 1.2 N in a horizontal progressive periodontal breakdown simulation of 0-8 mm. In all simulations, Tresca criteria accurately displayed the localized areas of maximum stress prone to external resorption risks, seeming to be adequate for the study of the resorptive process. The localized areas were better displayed in the radicular dentine-cementum component than in the entire tooth structure. The rotation and translation seem prone to a higher risk of external root resorption after 4 mm of loss. The resorptive risks seem to increase along with the progression of periodontal breakdown if the same amount of applied force is guarded. The localized resorption-prone areas follow the progression of bone loss. The two light forces displayed similar extensions of maximum stress areas. The stress displayed in the coronal dentine decreases along with the progression of bone loss. The absorption-dissipation ability of the tooth is about 87.99-97.99% of the stress.

5.
Article in English | MEDLINE | ID: mdl-36901151

ABSTRACT

Herein Finite elements analysis (FEA) study assesses the adequacy and accuracy of five failure criteria (Von Mises (VM), Tresca, maximum principal (S1), minimum principal (S3), and Hydrostatic pressure) for the study of tooth as a structure (made of enamel, dentin, and cement), along with its stress absorption-dissipation ability. Eighty-one 3D models of the second lower premolar (with intact and 1-8 mm reduced periodontium) were subjected to five orthodontic forces (intrusion, extrusion, tipping, rotation, and translation) of 0.5 N (approx. 50 gf) (in a total of 405 FEA simulations). Only the Tresca and VM criteria showed biomechanically correct stress display during the 0-8 mm periodontal breakdown simulation, while the other three showed various unusual biomechanical stress display. All five failure criteria displayed comparable quantitative stress results (with Tresca and VM producing the highest of all), showing the rotational and translational movements to produce the highest amount of stress, while intrusion and extrusion, the lowest. The tooth structure absorbed and dissipated most of the stress produced by the orthodontic loads (from a total of 0.5 N/50 gf only 0.125 N/12.5 gf reached PDL and 0.01 N/1 gf the pulp and NVB). The Tresca criterion seems to be more accurate than Von Mises for the study of tooth as structure.


Subject(s)
Periodontal Ligament , Tooth Movement Techniques , Tooth Movement Techniques/methods , Stress, Mechanical , Periodontium , Finite Element Analysis , Computer Simulation , Models, Biological
6.
Article in English | MEDLINE | ID: mdl-36767254

ABSTRACT

This study examines 0.6 N and 1.2 N as the maximum orthodontic force for periodontal ligament (PDL) at multiple levels of periodontal breakdown, and the relationships with the ischemic, necrotic, and resorptive risks. Additionally, this study evaluates if Tresca failure criteria is more adequate for the PDL study. Eighty-one 3D models (from nine patients; nine models/patients) with the 2nd lower premolar and different degrees of bone loss (0-8 mm) where subjected to intrusion, extrusion, rotation, translation, and tipping movements. Tresca shear stress was assessed individually for each movement and bone loss level. Rotation and translation produced the highest PDL stresses, while intrusion and extrusion determined the lowest. Apical and middle third PDL stresses were lower than the cervical stress. In intact periodontium, the amount of shear stress produced by the two investigated forces was lower than the 16 KPa of the maximum physiological hydrostatic pressure (MHP). In reduced periodontium (1-8 mm tissue loss), the apical amount of PDL shear stress was lower than MHP for both applied forces, while cervically for rotation, translation and tipping movements exceeded 16 KPa. Additionally, 1.2 N could be used in intact periodontium (i.e., without risks) and for the reduced periodontium only in the apical and middle third of PDL up to 8 mm of bone loss. However, for avoiding any resorptive risks, in the cervical third of PDL, the rotation, translation, and tipping movements require less than 0.2-0.4 N of force after 4 mm of loss. Tresca seems to be more adequate for the study of PDL than other criteria.


Subject(s)
Periodontal Ligament , Tooth Movement Techniques , Humans , Periodontal Ligament/physiology , Finite Element Analysis , Periodontium , Stress, Mechanical , Computer Simulation , Models, Biological
7.
Article in English | MEDLINE | ID: mdl-36673936

ABSTRACT

This study examines 0.6 N-4.8 N as the maximum orthodontic force to be applied to dental pulp and apical NVB on intact and 1-8 mm reduced periodontal-ligament (PDL), in connection with movement and ischemic, necrotic and resorptive risk. In addition, it examines whether the Tresca finite-element-analysis (FEA) criterion is more adequate for the examination of dental pulp and its apical NVB. Eighty-one (nine patients, with nine models for each patient) anatomically correct models of the periodontium, with the second lower-premolar reconstructed with its apical NVB and dental pulp were assembled, based on X-ray CBCT (cone-beam-computed-tomography) examinations and subjected to 0.6 N, 1.2 N, 2.4 N and 4.8 N of intrusion, extrusion, translation, rotation, and tipping. The Tresca failure criterion was applied, and the shear stress was assessed. Forces of 0.6 N, 1.2 N, and 2.4 N had negligible effects on apical NVB and dental pulp up to 8 mm of periodontal breakdown. A force of 4.8 N was safely applied to apical NVB on the intact periodontium only. Rotation and tipping seemed to be the most invasive movements for the apical NVB. For the dental pulp, only the translation and rotation movements seemed to display a particular risk of ischemia, necrosis, and internal orthodontic-resorption for both coronal (0-8 mm of loss) and radicular pulp (4-8 mm of loss), despite the amount of stress being lower than the MHP. The Tresca failure criterion seems more suitable than other criteria for apical NVB and dental pulp.


Subject(s)
Dental Pulp , Tooth Movement Techniques , Humans , Bicuspid , Dental Pulp/diagnostic imaging , Computer Simulation , Tooth Movement Techniques/methods , Periodontium/diagnostic imaging , Finite Element Analysis
SELECTION OF CITATIONS