Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Nanomedicine (Lond) ; 5(3): 369-78, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20394531

ABSTRACT

AIM: The goal of our research is to develop an ultrasensitive diagnostic platform called 'NanoMonitor' to enable rapid label-free analysis of a highly promising class of biomarkers called glycans (oligosaccharide chains attached to proteins) with high sensitivity and selectivity. The glycosylation of fetuin - a serum protein - and extracts from a human pancreatic cancer line was analyzed to demonstrate the capabilities of the NanoMonitor. MATERIAL & METHODS: The NanoMonitor device consists of a silicon chip with an array of gold electrodes forming multiple sensor sites and works on the principle of electrochemical impedance spectroscopy. Each sensor site is overlaid with a nanoporous alumina membrane that forms a high density of nanowells on top of each electrode. Lectins (proteins that bind to and recognize specific glycan structures) are conjugated to the surface of the electrode. When specific glycans from a test sample bind to lectins at the base of each nanowell, a perturbation of electrical double-layer occurs, which results in a change in the impedance. Using the lectins Sambucs nigra agglutinin (SNA) and Maackia amurensis agglutinin (MAA), subtle variations to the glycan chains of fetuin were investigated. Protein extracts from BXPC-3, a cultured human pancreatic cancer cell line were also analyzed for binding to SNA and MAA lectins. The performance of the NanoMonitor was compared to a conventional laboratory technique: lectin-based enzyme linked immunosorbent assay (ELISA). RESULTS & DISCUSSION: The NanoMonitor was used to identify glycoform variants of fetuin and global differences in glycosylation of protein extracts from cultured human pancreatic cancerous versus normal cells. While results from NanoMonitor correlate very well with results from lectin-based ELISA, the NanoMonitor is rapid, completely label free, requires just 10 microl of sample, is approximately five orders of magnitude more sensitive and highly selective over a broad dynamic range of glycoprotein concentrations. CONCLUSION: Based on its performance metrics, the NanoMonitor has excellent potential for development as a point-of-care handheld electronic biosensor device for routine detection of glycan biomarkers from clinical samples.


Subject(s)
Biomarkers/chemistry , Biosensing Techniques/instrumentation , Electrochemistry/instrumentation , Nanotechnology/instrumentation , Polysaccharides/analysis , Proteins/chemistry , Biomarkers/metabolism , Biosensing Techniques/methods , Cell Line, Tumor , Electrochemistry/methods , Equipment Design , Glycosylation , Humans , Lectins/chemistry , Lectins/metabolism , Nanotechnology/methods , Polysaccharides/metabolism , Proteins/metabolism , Sensitivity and Specificity , alpha-Fetoproteins/analysis , alpha-Fetoproteins/metabolism
2.
Biosens Bioelectron ; 25(10): 2336-42, 2010 Jun 15.
Article in English | MEDLINE | ID: mdl-20417087

ABSTRACT

The goal of our research is to demonstrate the feasibility of employing biogenic nanoporous silica as a key component in developing a biosensor platform for rapid label-free electrochemical detection of cardiovascular biomarkers from pure and commercial human serum samples with high sensitivity and selectivity. The biosensor platform consists of a silicon chip with an array of gold electrodes forming multiple sensor sites and works on the principle of electrochemical impedance spectroscopy. Each sensor site is overlaid with a biogenic nanoporous silica membrane that forms a high density of nanowells on top of each electrode. When specific protein biomarkers: C-reactive protein (CRP) and myeloperoxidase (MPO) from a test sample bind to antibodies conjugated to the surface of the gold surface at the base of each nanowell, a perturbation of electrical double layer occurs resulting in a change in the impedance. The performance of the biogenic silica membrane biosensor was tested in comparison with nanoporous alumina membrane-based biosensor and plain metallic thin film biosensor. Significant enhancement in the sensitivity and selectivity was achieved with the biogenic silica biosensor, in comparison to the other two, for detecting the two protein biomarkers from both pure and commercial human serum samples. The sensitivity of the biogenic silica biosensor is approximately 1 pg/ml and the linear dose response is observed over a large dynamic range from 1 pg/ml to 1 microg/ml. Based on its performance metrics, the biogenic silica biosensor has excellent potential for development as a point of care handheld electronic biosensor device for detection of protein biomarkers from clinical samples.


Subject(s)
Biosensing Techniques/instrumentation , Cardiovascular Diseases/blood , Cardiovascular Diseases/diagnosis , Conductometry/instrumentation , Cytokines/blood , Nanostructures/chemistry , Silicon Dioxide/chemistry , Biomarkers/blood , Biomimetic Materials/chemistry , Equipment Design , Equipment Failure Analysis , Humans , Nanostructures/ultrastructure , Nanotechnology/instrumentation , Porosity , Reproducibility of Results , Sensitivity and Specificity
3.
Nanomedicine ; 6(5): 642-50, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20353834

ABSTRACT

"Label-free" biomolecule sensors for detection of inflammatory cardiovascular biomarker associated with vulnerable coronary vascular plaque rupture were designed and fabricated using micro- and nanotextured polystyrene (PS) polymer structures that functioned as sensing elements coupled with electronic measurement equipment. We demonstrated that scaling down the surface texturing from the micro- to the nanoscale enhances the amplitude of the measured detected signal strength. We believe that the nanoscale fiber morphology provides size-matched spaces for trapping and immobilizing the protein biomolecule, resulting in improved detection signal strength. We selected PS as the model system and demonstrated the detection of human serum C-reactive protein. We employed these findings in designing a platform "lab-on-a-chip" protein sensor. Comparative studies were performed on PS textured surfaces of two different surface features: a PS microsphere mat and an electrospun PS nanofiber matrix. FROM THE CLINICAL EDITOR: In this study, nanotechnology-based biosensors for vulnerable coronary vascular plaque rupture were designed and fabricated using micro- and nanotextured polystyrene polymer structures. The authors demonstrated that scaling down the surface texturing from the micro- to the nanoscale enhances the sensitivity of this detection method.


Subject(s)
Nanostructures , Nanotechnology/methods , Proteins/analysis , Animals , Biosensing Techniques/methods , Humans , Microfluidics/methods , Nanofibers/chemistry , Nanostructures/chemistry , Polystyrenes/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...