Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Radiol Prot ; 38(1): 175-188, 2018 03.
Article in English | MEDLINE | ID: mdl-29182150

ABSTRACT

The use of radiological activity in the operating room (OR) and a regulatory decrease of the eye lens dose warrant an assessment of how medical staff are protected from radiation. This study aims to evaluate practices and knowledge in radiation protection (RP) for OR doctors before and after training. A descriptive study of surgeons and anesthetists in a French public hospital center was conducted in 2016. An ad hoc questionnaire concerning occupational practices and knowledge about RP was distributed before and one month after RP training. Among 103 doctors attending the training, 90 answered the questionnaire before the training. Results showed a lack of knowledge and good practice in RP. Most of the participants (86.7%) had never been trained in RP and recognized insufficient knowledge. Most of them (92.2%) wore a lead apron, 50.0% a thyroid-shield, 5.6% lead glasses, 53.3% a passive dosimeter and 17.8% an electronic dosimeter. None of them benefitted from collective protective equipment such as a ceiling suspended screen. The questionnaire following the training was completed by only 35 doctors. A comparison before and after training results showed an improvement in knowledge (scores of correct responses: 5.5/16 before and 9.5/16 after training) but not in RP good practices (scores of correct responses: 3.2/7 before and 3.3/7 after training). One training session appears to be insufficient to improve the application of the safety rules when x-rays are used. Communication needs to be improved regarding RP among anesthetists and surgeons, such as training renewal, workstation analysis in OR related to x-ray use and occupational medical follow-up. Otherwise, radiological risks in OR need to be given better consideration, such as radio-induced cataract risk. It is necessary to encourage the use of dosimeters and protective equipment and to strengthen access to lead glasses and collective protective equipment, such as ceiling suspended screens. All these recommendations ensure the received dose is reduced to as low as is reasonably achievable.


Subject(s)
Anesthetists/education , Health Knowledge, Attitudes, Practice , Radiation Protection , Surgeons/education , Adult , Female , Humans , Male , Middle Aged , Operating Rooms , Radiation Dosage , Radiation Dosimeters , Radiation Protection/instrumentation , Surveys and Questionnaires
2.
J Clin Endocrinol Metab ; 95(7): 3283-90, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20392868

ABSTRACT

CONTEXT: A few prospective studies have evaluated the use of recombinant human TSH (rhTSH) for radioiodine remnant ablation. OBJECTIVE: Our objective was to compare the effects of the both TSH regimens on iodine biokinetics in the thyroid remnant, dosimetry, and radiation protection. DESIGN: We conducted a prospective randomized study. MATERIALS AND METHODS: Eighty-eight patients were enrolled for radioiodine ablation to either the hypothyroid or rhTSH arms. A whole-body scan was performed at 48 and 144 h after therapy. Dose rates were assessed at 24, 48, and 144 h. Urinary samples were obtained during the first 48 h. Thyroglobulin was assessed before and after therapy. Iodine biokinetics in the remnants were calculated from gamma-count rates. Radiation-absorbed dose was calculated using OLINDA software. Exposure estimation was based on a validated model. RESULTS: The effective half-life in the remnant thyroid tissue was significantly longer after rhTSH than during hypothyroidism (P = 0.01), whereas 48-h (131)I uptakes and residence times were similar. After therapy, thyroglobulin release (a marker of cell damage) was lower in the rhTSH arm. The mean total-body effective half-life and residence time were shorter in patients treated after rhTSH. Residence time was also lower for the colon and stomach. Absorbed dose estimates were lower in the rhTSH arm for the lower large intestine, breasts, ovaries, and the bone marrow. Dose rates at the time of discharge were lower in the rhTSH group with a reduction in cumulative radiation exposure to contact persons. CONCLUSIONS: In comparison with thyroid hormone withdrawal, rhTSH is associated with longer remnant half-life of radioactive iodine while also reducing radiation exposure to the rest of the body and also to the general public who come in contact with such patients.


Subject(s)
Ablation Techniques/methods , Adenocarcinoma, Follicular/radiotherapy , Carcinoma, Papillary/radiotherapy , Iodine Radioisotopes/therapeutic use , Iodine/metabolism , Thyroid Neoplasms/radiotherapy , Thyrotropin/therapeutic use , Adenocarcinoma, Follicular/surgery , Carcinoma, Papillary/surgery , Combined Modality Therapy , Half-Life , Humans , Prospective Studies , Radiometry , Recombinant Proteins/therapeutic use , Thyroid Gland/radiation effects , Thyroid Neoplasms/surgery , Thyroxine/therapeutic use , Treatment Outcome , Triiodothyronine/therapeutic use
3.
J Radiol ; 88(3 Pt 1): 361-6, 2007 Mar.
Article in French | MEDLINE | ID: mdl-17457267

ABSTRACT

OBJECTIVE: Compare the irradiation delivered in conventional radiography and digital radiography by image intensifier during a scoliosis workup. PATIENTS AND METHODS: Our prospective randomized study included 105 patients, all of whom were identified according to sociodemographic parameters as well as criteria evaluating the quality of the full front spinal x-ray at PA incidence. The entry dose at the scapula and the exit dose in interorbital, thyroid, mammary, and hypogastric projection was measured by thermoluminescent dosimeters. RESULTS: The results of 71 girls and 28 boys, aged a mean 13.8 years with a mean weight of 47 kg were analyzed. At equal image quality, the entry dose was not significantly different between the two techniques; the mean exit dose reduction was 64% during digital acquisition. This reduction involved the interorbital (162%), mammary (43%), and thyroid (309%) regions. However, this system is more irradiating in the hypogastric region (34%). CONCLUSION: The dosimetric evaluation of the different imaging techniques used to explore the entirety of the spine should be part of radiologists' quality standard used to document their work and their choices.


Subject(s)
Fluoroscopy , Radiographic Image Enhancement , Radiography , Scoliosis/diagnostic imaging , Thermoluminescent Dosimetry , Adolescent , Child , Female , Humans , Male , Radiation Injuries/etiology , Radiation Injuries/prevention & control , Spine/diagnostic imaging
4.
J Med Virol ; 43(1): 28-32, 1994 May.
Article in English | MEDLINE | ID: mdl-7916032

ABSTRACT

A simple and rapid assay for the quantification of infectious HIV-1 in plasma was developed using short-term culture and DNA PCR. This method, called culture PCR, allows detection and quantification of infectious HIV-1 viraemia within 48 hours, and measures the number of infectious cell-free HIV-1 particles, expressed as culture PCR infectious doses (CPID/ml). 42 HIV infected subjects were assessed by this method. The titres obtained by CPID closely correlated with CD4+ count and clinical status. CPID titres had significant correlation with infectious virus titre determined by conventional limiting dilution tissue-culture methods. This culture-PCR technique permits rapid assessment of infectious plasma viraemia, and is comparable to longer culture based assay methods.


Subject(s)
AIDS-Related Complex/diagnosis , Acquired Immunodeficiency Syndrome/diagnosis , DNA, Viral/blood , HIV Seropositivity/diagnosis , HIV-1/isolation & purification , Polymerase Chain Reaction/methods , Viremia/diagnosis , AIDS-Related Complex/blood , Acquired Immunodeficiency Syndrome/blood , Base Sequence , CD4-Positive T-Lymphocytes/immunology , Cells, Cultured , Culture Techniques/methods , DNA Primers , DNA, Viral/isolation & purification , HIV Core Protein p24/analysis , HIV Seropositivity/blood , Humans , Leukocyte Count , Lymphocytes/cytology , Molecular Sequence Data , Predictive Value of Tests , Viremia/blood
SELECTION OF CITATIONS