1.
Med Eng Phys ; 127: 104167, 2024 May.
Article in English | MEDLINE | ID: mdl-38692766

ABSTRACT

BACKGROUND: Recent studies have stated the relevance of having new parameters to quantify the position and orientation of the scapula with patients standing upright. Although biplanar radiography can provide 3D reconstructions of the scapula and the spine, it is not yet possible to acquire these images with patients in the same position. METHODS: Two pairs of images were acquired, one for the 3D reconstruction of the spine and ribcage and one for the 3D reconstruction of the scapula. Following 3D reconstructions, scapular alignment was performed in two stages, a coarse alignment based on manual annotations of landmarks on the clavicle and pelvis, and an adjusted alignment. Clinical parameters were computed: protraction, internal rotation, tilt and upward rotation. Reproducibility was assessed on an in vivo dataset of upright biplanar radiographs. Accuracy was assessed using supine cadaveric CT-scans and digitally reconstructed radiographs. FINDINGS: The mean error was less than 2° for all clinical parameters, and the 95 % confidence interval for reproducibility ranged from 2.5° to 5.3°. INTERPRETATION: The confidence intervals were lower than the variability measured between participants for the clinical parameters assessed, which indicates that this method has the potential to detect different patterns in pathological populations.


Subject(s)
Imaging, Three-Dimensional , Posture , Scapula , Scapula/diagnostic imaging , Humans , Male , Female , Adult , Reproducibility of Results , Radiography/methods , Middle Aged , Tomography, X-Ray Computed , Aged
2.
Med Eng Phys ; 120: 104043, 2023 10.
Article in English | MEDLINE | ID: mdl-37838397

ABSTRACT

BACKGROUND: Patient-specific scapular shape in functional posture can be highly relevant to clinical research. Biplanar radiography is a relevant modality for that purpose with already two existing assessment methods. However, they are either time-consuming or lack accuracy. The aim of this study was to propose a new, more user-friendly and accurate method to determine scapular shape. METHODS: The proposed method relied on simplified manual inputs and an upgraded version of the first 3D estimate based on statistical inferences and Moving-Least Square (MLS) deformation of a template. Then, manual adjustments, with real-time MLS algorithm and contour matching adjustments with an adapted minimal path method, were added to improve the match between the projected 3D model and the radiographic contours. The accuracy and reproducibility of the method were assessed (with 6 and 12 subjects, respectively). FINDINGS: The shape accuracy was in average under 2 mm (1.3 mm in the glenoid region). The reproducibility study on the clinical parameters found intra-observer 95% confidence intervals under 3 mm or 3° for all parameters, except for glenoid inclination and Critical Shoulder Angle, ranging between 3° and 6°. INTERPRETATION: This method is a first step towards an accurate reconstruction of the scapula to assess clinical parameters in a functional posture. This can already be used in clinical research on non-pathologic bones to investigate the scapulothoracic joint in functional position.


Subject(s)
Imaging, Three-Dimensional , Shoulder Joint , Humans , X-Rays , Imaging, Three-Dimensional/methods , Reproducibility of Results , Radiography , Scapula/diagnostic imaging , Scapula/anatomy & histology , Shoulder Joint/surgery