1.
Rev Sci Instrum ; 89(5): 055107, 2018 May.
Article in English | MEDLINE | ID: mdl-29864801

ABSTRACT

A new thermal conductivity probe for high temperature (HT-TCP) has been built and tested. Its design and construction procedure are adapted from the ambient temperature thermal conductivity probe (AT-TCP) due to good performance of the latter device. The construction procedure and the preliminary tests are accurately described. The probe contains a Pt wire as a heater and a type K thermocouple (TC) as a temperature sensor, and its size is so small (0.6 mm in diameter and 60 mm in length) as to guarantee a length to diameter ratio of about 100. Calibration tests with glycerol for temperatures between 0 °C and 60 °C have shown good agreement with literature data, within 3%. Preliminary tests were also carried on a ternary molten salt for Concentrated Solar Power (CSP) (18% in mass of NaNO3, 52% KNO3, and 30% LiNO3) at 120 °C and 150 °C. Obtained results are within λ range of the Hitec® salt (53% KNO3, 7% NaNO3, 40% NaNO2). Unfortunately, at the higher temperature tested (200 °C), the viscosity of the salt highly decreases, and free convection starts, making the measurements unreliable.

2.
Biomed Res Int ; 2016: 1894672, 2016.
Article in English | MEDLINE | ID: mdl-27195282

ABSTRACT

Objectives. The aim of this in vitro study was to assess thermal changes on tooth tissues during light exposure using two different LED curing units. The hypothesis was that no temperature increase could be detected within the dental pulp during polymerization irrespective of the use of a composite resin or a light-curing unit. Methods. Caries-free human first molars were selected, pulp residues were removed after root resection, and four calibrated type-J thermocouples were positioned. Two LED lamps were tested; temperature measurements were made on intact teeth and on the same tooth during curing of composite restorations. The data was analyzed by one-way analysis of variance (ANOVA), Wilcoxon test, Kruskal-Wallis test, and Pearson's χ (2). After ANOVA, the Bonferroni multiple comparison test was performed. Results. Polymerization data analysis showed that in the pulp chamber temperature increase was higher than that without resin. Starlight PRO, in the same condition of Valo lamp, showed a lower temperature increase in pre- and intrapolymerization. A control group (without composite resin) was evaluated. Significance. Temperature increase during resin curing is a function of the rate of polymerization, due to the exothermic polymerization reaction, the energy from the light unit, and time of exposure.


Subject(s)
Curing Lights, Dental , Dental Caries/therapy , Dental Pulp Cavity/radiation effects , Tooth/radiation effects , Acrylic Resins/radiation effects , Acrylic Resins/therapeutic use , Composite Resins/radiation effects , Composite Resins/therapeutic use , Dental Caries/pathology , Dental Pulp Cavity/pathology , Humans , Molar/pathology , Molar/radiation effects , Polyurethanes/radiation effects , Polyurethanes/therapeutic use , Temperature , Tooth/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...