Results 1 - 20 de 22
Filter
1.
Pacing Clin Electrophysiol ; 46(7): 563-573, 2023 07.
Article in English | MEDLINE | ID: mdl-37377391

ABSTRACT

BACKGROUND: Although pulmonary vein isolation (PVI) remains the cornerstone of catheter ablation of atrial fibrillation (AF), several studies have illustrated clinical benefits associated with PVI with posterior wall isolation (PWI). METHODS: This retrospective study investigated the outcomes of PVI alone versus PVI+PWI performed using the cryoballoon in patients with cardiac implantable electronic devices (CIEDs) and paroxysmal AF (PAF) or persistent AF (PersAF). RESULTS: Acute PVI was achieved in all patients using cryoballoon ablation. Compared to PVI alone, PVI+PWI was associated with longer cryoablation, fluoroscopy, and total procedure times. Adjunct radiofrequency was required to complete PWI in 29/77 patients (37.7%). Adverse events were similar with PVI alone versus PVI+PWI. But at 24 ± 7 months of follow-up, not only cryoballoon PVI+PWI was associated with improved freedom from recurrent AF (74.3% vs. 46.0%, P = .007) and all atrial tachyarrhythmias (71.4% vs. 38.1%, P = .001) in patients with PersAF, cryoballoon PVI+PWI also yielded greater freedom from AF (88.1% vs. 63.7%, P = .003) and all atrial tachyarrhythmias (83.3% vs. 60.8%, P = .008) in those with PAF. Additionally, PVI+PWI was associated with higher reductions in atrial tachyarrhythmia burden (97.9% vs. 91.6%, P < .001), need for cardioversion (5.2% vs. 23.6%, P < .001) and repeat catheter ablation (10.4% vs. 26.1%, P = .005), and a longer time-to-arrhythmia recurrence (16 ± 6 months vs. 8 ± 5 months, P < .001) in both PersAF and PAF patients. CONCLUSION: In CIED patients with PersAF or PAF, cryoballoon PVI+PWI is associated with a greater freedom from recurrent AF and atrial tachyarrhythmias, as compared to PVI alone during long-term follow-up.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Retrospective Studies , Treatment Outcome , Heart Atria , Pulmonary Veins/surgery , Cryosurgery/methods , Catheter Ablation/methods , Recurrence
2.
JACC Clin Electrophysiol ; 9(5): 628-637, 2023 05.
Article in English | MEDLINE | ID: mdl-37225309

ABSTRACT

BACKGROUND: Prior studies have demonstrated clinical benefits associated with cryoballoon pulmonary vein isolation (PVI) and concomitant posterior wall isolation (PWI) in patients with persistent atrial fibrillation (AF). However, the role for this approach in patients with paroxysmal atrial fibrillation (PAF) remains unclear. OBJECTIVES: This study investigated the acute and long-term outcomes of PVI vs PVI+PWI using cryoballoon in patients with symptomatic PAF. METHODS: This retrospective study (NCT05296824) examined the outcomes of cryoballoon PVI (n = 1,342) vs cryoballoon PVI+PWI (n = 442) in patients with symptomatic PAF during long-term follow-up. Using the nearest-neighbor method, a 1:1 matched sample of patients receiving PVI alone and PVI+PWI was created. RESULTS: The matched cohort consisted of 320 patients (PVI: n = 160; PVI+PWI: n = 160). PVI+PWI was associated with longer cryoablation (23 ± 10 minutes vs 42 ± 11 minutes; P < 0.001) and procedure times (103 ± 24 minutes vs 127 ± 14 minutes; P < 0.001). In 39 (24.4%) of 160 patients, adjunct radiofrequency ablation was required for PVI+PWI. Adverse event rates were similar (PVI 3.8% vs PVI+PWI 1.9%; P = 0.31). Though there were no differences at 12 months, freedom from all atrial arrhythmias (67.5% vs 45.0%; P < 0.001) and AF (75.6% vs 55.0%; P < 0.001) were significantly greater with PVI+PWI vs PVI alone at 39 ± 9 months of follow-up. PVI+PWI was also associated with reduced long-term need for cardioversion (16.9% vs 27.5%; P = 0.02) and repeat catheter ablation (11.9% vs 26.3%; P = 0.001), and emerged as the only significant predictor of freedom from recurrent AF (HR: 2.79; 95% CI: 1.64-4.74; P < 0.001). CONCLUSIONS: Compared with cryoballoon PVI, cryoballoon PVI+PWI appears to be associated with greater freedom from recurrent atrial arrhythmias and AF in patients with PAF during long-term follow-up >3 years.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Retrospective Studies , Catheter Ablation/adverse effects , Cryosurgery/adverse effects
3.
J Interv Card Electrophysiol ; 66(1): 99-107, 2023 Jan.
Article in English | MEDLINE | ID: mdl-34988846

ABSTRACT

PURPOSE: Due to their internal rotating magnets, conventional impeller-driven percutaneous ventricular assist devices (PVADs) yield high-frequency electrogram artifact and electromagnetic interference (EMI) when used with magnetic-based 3D electroanatomic mapping systems. The new percutaneous heart pump (PHP; Abbott, Chicago, IL) is a 14-French, 5-L/min, impeller axial-flow PVAD with a novel design that utilizes an external motor. METHODS: We evaluated the feasibility of 3D mapping and radiofrequency ablation (RFA) in vivo during PHP mechanical circulatory support (MCS) in simulated ventricular tachycardia (pacing at 300 ms) and ventricular flutter (VFL, pacing at 200 ms) and also during ventricular fibrillation (VF) in a porcine model. Anterograde (right ventricular), transseptal, retrograde, and epicardial right and left ventricular 3D mapping (EnSite/CARTO) and RFA were performed in 6 swine using high-density mapping and force-sensing RFA catheters (TactiCath/ThermoCool). Surface and intracardiac electrograms and 3D maps were analyzed for noise/interference with and without MCS using PHP in sinus rhythm and simulated VT/VFL and VF. RESULTS: Mapping and RFA proved feasible in the presence of MCS using PHP. The mean arterial pressure in sinus rhythm was 55 ± 2 mmHg (baseline) and 84 ± 4 mmHg during MCS with PHP and well-maintained during simulated VT (73 ± 8 mmHg) and VFL (65 ± 2 mmHg) and even in VF (65 ± 5 mmHg). No electrogram noise/artifact, EMI, or 3D map distortions were observed during mapping/RFA with either of two mapping systems. CONCLUSIONS: Endocardial and epicardial 3D mapping and RFA in the presence of PHP are feasible and offer significant MCS during simulated VT/VFL and VF. Furthermore, PHP yielded no electrogram noise/artifact, EMI, or 3D mapping distortions in conjunction with magnetic-based 3D mapping systems.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Animals , Swine , Tachycardia, Ventricular/surgery , Ventricular Fibrillation , Arrhythmias, Cardiac/surgery , Heart Ventricles/surgery , Epicardial Mapping , Catheter Ablation/methods
5.
JACC Clin Electrophysiol ; 7(2): 187-196, 2021 02.
Article in English | MEDLINE | ID: mdl-33602399

ABSTRACT

OBJECTIVES: The aim of this multicenter, randomized, single-blind study was to prospectively evaluate the short-and long-term outcomes of pulmonary vein isolation (PVI) versus PVI with concomitant left atrial posterior wall isolation (PWI) using the cryoballoon in patients with symptomatic persistent/long-standing persistent atrial fibrillation (P/LSP-AF). BACKGROUND: Some studies have suggested a clinical benefit associated with PVI+PWI in patients with P/LSP-AF. However, there are limited safety and efficacy data on this approach using cryoballoon ablation. METHODS: The immediate and long-term outcomes in patients with P/LSP-AF randomized to PVI (n = 55) versus PVI+PWI (n = 55) using the cryoballoon were prospectively examined. RESULTS: Baseline characteristics were similar. PVI was achieved in all patients (21 ± 11 min). PWI was attained using 23 ± 8 min of cryoablation. Adjunct radiofrequency ablation was required in 4 of 110 patients (7.3%) to complete PVI (3 ± 2 min) and in 25 of 55 patients (45.5%) to complete PWI (4 ± 6 min). Although left atrial dwell time (113 ± 31 min vs. 75 ± 32 min; p < 0.001) and total procedure time (168 ± 34 min vs. 127 ± 40 min; p < 0.001) were longer with PVI+PWI, this cohort required fewer intraprocedural cardioversions (89.1% vs. 96.4%; p = 0.04). Adverse events occurred in 5.5% in each group (p = 1.00). However, the incidence of recurrent atrial fibrillation at 12 months was significantly lower with PVI+PWI (25.5% vs. 45.5%; p = 0.028). Additionally, in a multivariate analysis, PVI+PWI emerged as a significant predictor of freedom from recurrent atrial fibrillation (odds ratio: 3.67; 95% confidence interval: 1.44 to 9.34; p = 0.006). CONCLUSIONS: In patients with P/LSP-AF, PVI+PWI using the cryoballoon is associated with a significant reduction in atrial fibrillation recurrence, but similar safety, as compared with PVI alone.


Subject(s)
Atrial Fibrillation , Pulmonary Veins , Atrial Fibrillation/surgery , Humans , Pulmonary Veins/surgery , Recurrence , Single-Blind Method , Treatment Outcome
6.
J Cardiovasc Electrophysiol ; 32(2): 183-190, 2021 02.
Article in English | MEDLINE | ID: mdl-33345408

ABSTRACT

BACKGROUND: It is common practice to observe patients during an overnight stay (ONS) following a catheter ablation procedure for the treatment of atrial fibrillation (AF). OBJECTIVES: To investigate the safety and economic impact of a same-day discharge (SDD) protocol after cryoballoon ablation for treatment of AF in high-volume, geographically diverse US hospitals. METHODS: We retrospectively reviewed 2374 consecutive patients (1119 SDD and 1180 ONS) who underwent cryoballoon ablation for AF at three US centers. Baseline characteristics, acute procedure-related complications, and longer-term evaluations of safety were recorded during routine clinical follow-up. The mean cost of an ONS was used in a one-way sensitivity analysis to evaluate yearly cost savings as a function of the percentage of SDD cases per year. RESULTS: The SDD and ONS cohorts were predominately male (69% vs. 67%; p = .3), but SDD patients were younger (64 ± 11 vs. 66 ± 10; p < .0001) with lower body mass index (30 ± 6 vs. 31 ± 61; p < .0001) and CHA2 DS2 -VASc scores (1.4 ± 1.0 vs. 2.2 ± 1.4; p < .0002). There was no difference between SDD and ONS in the 30-day total complication rate (n = 15 [1.26%] versus n = 24 [2.03%]; p = .136, respectively). The most common complication was hematoma in both the SDD (n = 8; 0.67%) and ONS (n = 11; 0.93%) cohorts. Sensitivity analysis demonstrated that when 50% of every 100 patients treated were discharged the same day, hospital cost savings ranged from $45 825 to $83 813 per year across US hospitals. CONCLUSIONS: SDD following cryoballoon ablation for AF appears to be safe and is associated with cost savings across different US hospitals.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Humans , Male , Patient Discharge , Pulmonary Veins/surgery , Retrospective Studies , Treatment Outcome
7.
J Interv Card Electrophysiol ; 62(1): 161-169, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33000358

ABSTRACT

PURPOSE: There is a growing interest in performing pulmonary vein isolation (PVI) with concomitant posterior wall isolation (PWI) using the cryoballoon for the treatment of patients with persistent atrial fibrillation (AF). However, there is little known about the long-term durability of PWI using this approach. METHODS: In this multicenter study, we retrospectively examined the durability of PVI + PWI using the 28-mm cryoballoon by investigating the outcomes from consecutive patients referred for repeat catheter ablation. RESULTS: Altogether, 81/519 patients (15.6%) were referred for repeat catheter ablation. Repeat ablation was associated with a longer AF duration, hypertension, heart failure, multiple cardioversions, and antiarrhythmic therapy as well as larger left atrial (LA) diameters (49 ± 4 mm versus 43 ± 5 mm; P < 0.001) and greater need for "touch-up" (adjunct) radiofrequency ablation (44.4% versus 18.3%; P < 0.001). LA diameter also emerged as a significant predictor for adjunct radiofrequency ablation (P < 0.001). Durable PVI was observed in 66/81 patients (81.5%) and PWI in 67/81 patients (82.7%). Those with incomplete PWI exhibited larger LA diameters, particularly > 48 mm (negative predictive value = 89.7%). Lastly, an atypical LA posterior wall/roof flutter represented the third most common cause of arrhythmia recurrence and essentially every patient with incomplete PWI exhibited such an arrhythmia. CONCLUSION: PWI performed using a 28-mm cryoballoon in conjunction with PVI exhibits long-term durability in the vast majority of patients with persistent AF. While LA diameter (particularly > 48 mm) is a significant predictor for the need for adjunct radiofrequency ablation when performing this technique, those with incomplete PWI invariably present with an atypical flutter using this substrate.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
10.
Heart Rhythm ; 15(8): 1121-1129, 2018 08.
Article in English | MEDLINE | ID: mdl-30060879

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) in conjunction with isolation of the posterior left atrial wall (PVI+PWI) is associated with improved clinical outcomes in certain patients with atrial fibrillation (AF). OBJECTIVE: The purpose of this multicenter study was to evaluate the acute and long-term outcomes of PVI+PWI vs PVI alone performed using cryoballoon ablation in patients with persistent AF (persAF). METHODS: We examined the procedural safety and efficacy and short- and long-term outcomes in 390 consecutive patients with persAF who underwent a first-time cryoballoon ablation procedure using PVI+PWI (n = 222 [56.9%]) vs PVI alone (n = 168 [43.1%]). RESULTS: Acute isolation was achieved in 99.7% of all pulmonary veins (PVI+PWI = 99.8% vs PVI alone = 99.3%; P = .23) using 6.3 ± 1.4 applications and 17 ± 2 minutes of cryoablation. PWI was achieved using 13.7 ± 3.2 applications and 34 ± 10 minutes of cryoablation. Adjunct radiofrequency ablation was required in 1.8% of patients to complete PVI (4 ± 2 minutes) and in 32.4% to complete PWI (5 ± 2 minutes). PVI+PWI yielded significantly greater posterior wall (77.2% ± 6.4% vs 40.6% ± 4.9%; P < .001) and total left atrial (53.3% ± 4.2% vs 36.3% ± 3.8%; P < .001) isolation. In addition, PVI+PWI was associated with greater AF termination (19.8% vs 8.9%; P = .003) and conversion to atrial flutters (12.2% vs 5.4%; P = .02). Adverse events were similar in both groups, whereas recurrence of AF and all atrial arrhythmias was lower with PVI+PWI at 12 months of follow-up. Moreover, in a Cox regression analysis, PVI+PWI emerged as a significant predictor of freedom from recurrent atrial arrhythmias (hazard ratio: 2.04; 95% confidence interval: 1.15-3.61; P = .015). CONCLUSION: PVI+PWI can be achieved safely and effectively using the cryoballoon. This approach appears superior to PVI alone in patients with persAF.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery/methods , Heart Conduction System/surgery , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/physiopathology , Female , Follow-Up Studies , Heart Atria/surgery , Heart Conduction System/physiopathology , Humans , Male , Recurrence , Retrospective Studies , Time Factors , Treatment Outcome
12.
J Cardiovasc Electrophysiol ; 28(11): 1295-1302, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28800178

ABSTRACT

INTRODUCTION: There is a paucity of data in favor of mechanical support during catheter ablation of ventricular tachycardia (VT). This study investigated the outcomes of VT ablation associated with mechanical support using percutaneous ventricular assist device (PVAD) versus intra-aortic balloon pump (IABP). METHODS AND RESULTS: We retrospectively examined the outcomes of patients who underwent VT ablation associated with PVAD versus IABP from 2010 to 2013, captured by the Medicare Inpatient Standard Analytic File database. Data from 345 patients (PVAD = 230, IABP = 115) were examined. On admission, the incidence of heart failure was higher in PVAD (84.3% vs. 73.0%; P = 0.01) with similar rates of renal failure in PVAD versus IABP (33.0% vs. 37.4%; P = 0.42). However, PVAD was associated with reduced in-hospital cardiogenic shock (9.1% vs. 23.5%; P  <  0.001), renal failure (11.7% vs. 21.7%; P = 0.01), and length of stay (8.4 ± 7.9 vs. 10.6 ± 7.5; P < 0.001), but with greater hospital discharges to home/self-care (66.0% vs. 51.6%; P = 0.02). Index mortality (6.5% vs. 19.1%; P = 0.001) and mortality in patients with cardiogenic shock (18.2% vs. 41.2%; P = 0.03) were significantly lower with PVAD versus IABP. Furthermore, PVAD was associated with lower all-cause (27.0% vs. 38.7%; P = 0.04) and heart failure-related (21.4% vs. 33.3%; P = 0.03) 30-day hospital readmissions, but with similar redo-VT ablation rates at 1 year (10.2% vs. 14.0%; P = 0.34). CONCLUSION: Among the cases captured by the Medicare database, catheter ablation of VT associated with mechanical support using PVAD was associated with reduced in-hospital cardiogenic shock, renal failure, length of stay, hospital readmissions and mortality, but no difference in redo-VT ablation at 1 year.


Subject(s)
Catheter Ablation/trends , Databases, Factual/trends , Heart-Assist Devices/trends , Medicare/trends , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/surgery , Aged , Aged, 80 and over , Female , Hemodynamics/physiology , Humans , Longitudinal Studies , Male , Patient Discharge/trends , Retrospective Studies , Tachycardia, Ventricular/physiopathology , United States/epidemiology
13.
Heart Rhythm ; 14(9): 1319-1325, 2017 09.
Article in English | MEDLINE | ID: mdl-28625929

ABSTRACT

BACKGROUND: There are no recommendations on the optimal dosing for cryoablation of atrial fibrillation (Cryo-AF). OBJECTIVE: The purpose of this study was to develop and prospectively test a Cryo-AF dosing protocol guided exclusively by time-to-pulmonary vein (PV) isolation (TT-PVI) in patients undergoing a first-time Cryo-AF. METHODS: In this multicenter study, we examined the acute/long-term safety/efficacy of Cryo-AF using the proposed dosing algorithm (Cryo-AFDosing; n = 355) against a conventional, nonstandardized approach (Cryo-AFConventional; n = 400) in a nonrandomized fashion. RESULTS: Acute PV isolation was achieved in 98.9% of patients in Cryo-AFDosing (TT-PVI = 48 ± 16 seconds) vs 97.2% in Cryo-AFConventional (P = .18). Cryo-AFDosing was associated with shorter (149 ± 34 seconds vs 226 ± 46 seconds; P <.001) and fewer (1.7 ± 0.8 vs 2.9 ± 0.8; P <.001) cryoapplications, reduced overall ablation (16 ± 5 minutes vs 40 ± 14 minutes; P <.001), fluoroscopy time (13 ± 6 minutes vs 29 ± 13 minutes; P <.001), left atrial dwell time (51 ± 14 minutes vs 118 ± 25 minutes; P <.001), and total procedure time (84 ± 23 minutes vs 145 ± 49 minutes; P <.001) but similar nadir balloon temperature (-47°C ± 8°C vs -48°C ± 6°C; P = .41) and total thaw time (43 ± 27 seconds vs 45 ± 19 seconds; P = .09) as compared to Cryo-AFConventional. Adverse events (2.0% vs 2.7%; P = .48), including persistent phrenic nerve palsy (0.6% vs 1.2%; P = .33) and 12-month freedom from all atrial arrhythmias (82.5% vs 78.3%; P = .14), were similar between Cryo-AFDosing and Cryo-AFConventional. However, Cryo-AFDosing was specifically associated with fewer atypical atrial flutters/tachycardias during long-term follow-up (8.5% vs 13.5%; P = .02) as well as fewer late PV reconnections at redo procedures (5.0% vs 18.5%; P <.001). CONCLUSION: A novel Cryo-AF dosing algorithm guided by TT-PVI can help individualize the ablation strategy and yield improved procedural endpoints and efficiency as compared to a conventional, nonstandardized approach.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/instrumentation , Heart Conduction System/surgery , Pulmonary Veins/surgery , Surgery, Computer-Assisted/methods , Tachycardia, Paroxysmal/surgery , Algorithms , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Cardiac Catheterization , Equipment Design , Female , Fluoroscopy/methods , Follow-Up Studies , Heart Conduction System/physiopathology , Humans , Male , Middle Aged , Recurrence , Retrospective Studies , Tachycardia, Paroxysmal/diagnosis , Tachycardia, Paroxysmal/physiopathology , Time Factors
14.
Heart Rhythm ; 13(12): 2306-2313, 2016 12.
Article in English | MEDLINE | ID: mdl-27503480

ABSTRACT

BACKGROUND: Limited data exist on cryoablation of atrial fibrillation (Cryo-AF) using the newly available third-generation (Arctic Front Advance-Short Tip [AFA-ST]) cryoballoon. OBJECTIVE: In this multicenter study, we evaluated the safety and efficacy of Cryo-AF using the AFA-ST vs the second-generation (Arctic Front Advance [AFA]) cryoballoon. METHODS: We examined the procedural safety and efficacy and the short- and long-term clinical outcomes associated with a first-time Cryo-AF performed in 355 consecutive patients (254/355 [72%] with paroxysmal AF), using either the AFA-ST (n = 102) or the AFA (n = 253) cryoballoon catheters. RESULTS: Acute isolation was achieved in 99.6% of all pulmonary veins (PVs) (AFA-ST: 100% vs AFA: 99.4%; P = .920). Time to pulmonary vein isolation was recorded in 89.2% of PVs using AFA-ST vs 60.2% using AFA (P < .001). PVs targeted using AFA-ST required fewer applications (1.6 ± 0.8 vs 1.7 ± 0.8; P = .023), whereas there were no differences in the balloon nadir temperature (AFA-ST: -47.0°C ± 7.3°C vs AFA: -47.5°C ± 7.8°C; P = .120) or thaw time (AFA-ST: 41 ± 24 seconds vs AFA: 44 ± 28 seconds; P = .056). However, AFA-ST was associated with shorter left atrial dwell time (43 ± 5 minutes vs 53 ± 16 minutes; P < .001) and procedure time (71 ± 11 minutes vs 89 ± 25 minutes; P < .001). Furthermore, Cryo-AF using AFA-ST was completed more frequently by "single-shot" PV ablation (27.4% vs 20.2%; P = .031). Persistent phrenic nerve palsy (AFA-ST: 0% vs AFA: 0.8%; P = .507) and procedure-related adverse events (AFA-ST: 1.0% vs AFA: 1.6%; P = .554) were similar, as was the freedom from recurrent atrial arrhythmias at 10 months of follow-up (AFA-ST: 81.8% vs AFA: 79.9%; P = .658). CONCLUSION: Cryo-AF using the AFA-ST cryoballoon offers an enhanced ability to assess time to pulmonary vein isolation, allowing for fewer cryoapplications and shorter left atrial dwell time and procedure time. Consequently, this allowed for procedural completion more frequently using a "single-shot" PV ablation with equivalent safety and efficacy.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Long Term Adverse Effects , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/epidemiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cohort Studies , Cryosurgery/instrumentation , Cryosurgery/methods , Equipment Design , Female , Humans , Long Term Adverse Effects/diagnosis , Long Term Adverse Effects/epidemiology , Male , Middle Aged , Quality Improvement , Recurrence , Time Factors , Treatment Outcome , United States/epidemiology
15.
J Interv Card Electrophysiol ; 47(3): 341-348, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27475949

ABSTRACT

PURPOSE: Catheter ablation of atrial fibrillation (CAAF) using the cryoballoon has emerged as an alternate strategy to point-by-point radiofrequency. However, there is little comparative data on long-term durability of pulmonary vein (PV) isolation comparing these two modalities. METHODS: In this multicenter, retrospective analysis, the incidences/patterns of late PV reconnection following an index CAAF using the second-generation cryoballoon versus open-irrigated, non-force-sensing radiofrequency were examined. RESULTS: Of the 2002 patients who underwent a first-time CAAF, 186/1126 patients (16.5 %) ablated using cryoballoon and 174/876 patients (19.9 %) with non-contact force-guided radiofrequency required a repeat procedure at 11 ± 5 months. During follow-up, the incidence of atrial flutters/tachycardias was lower (19.9 vs. 32.8 %; p = 0.005) and fewer patients exhibited PV reconnection (47.3 vs. 60.9 %; p = 0.007) with cryoballoon versus radiofrequency. Additionally, fewer PVs had reconnected with cryoballoon versus radiofrequency (18.8 vs. 34.6 %; p < 0.001). With cryoballoon, the right inferior (p < 0.001) and left common (p = 0.039) PVs were more likely to exhibit late reconnection, versus the left superior PV with radiofrequency (p = 0.012). However, when comparing the two strategies, the left common PV was more likely to exhibit reconnection with cryoballoon, whereas all other PVs with the exception of the right inferior PV demonstrated a lower reconnection rate with cryoballoon versus radiofrequency. Lastly, in a logistic regression multivariate analysis, cryoballoon ablation and PV ablation time emerged as significant predictors of durable PV isolation at repeat procedure. CONCLUSIONS: In this large multicenter, retrospective analysis, CAAF using the second-generation cryoballoon was associated with improved durability of PV isolation compared to open-irrigated, non-force-sensing radiofrequency.


Subject(s)
Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Cryosurgery/instrumentation , Pulmonary Veins/surgery , Therapeutic Irrigation/statistics & numerical data , Atrial Fibrillation/diagnosis , Catheter Ablation/statistics & numerical data , Cryosurgery/statistics & numerical data , Equipment Design , Equipment Failure Analysis , Female , Heart Conduction System/surgery , Humans , Incidence , Internationality , Male , Middle Aged , Operative Time , Prevalence , Recurrence , Risk Factors , Treatment Failure , Treatment Outcome
16.
Heart Rhythm ; 13(8): 1602-11, 2016 08.
Article in English | MEDLINE | ID: mdl-27165695

ABSTRACT

BACKGROUND: The optimal irrigation flow rate (IFR) during epicardial radiofrequency (RF) ablation has not been established. OBJECTIVE: This study specifically examined the impact of IFR and intrapericardial fluid (IPF) accumulation during epicardial RF ablation. METHODS: Altogether, 452 ex vivo RF applications (10 g for 60 seconds) delivered to the epicardial surface of bovine myocardium using 3 open-irrigated ablation catheters (ThermoCool SmartTouch, ThermoCool SmartTouch-SF, and FlexAbility) and 50 in vivo RF applications delivered (ThermoCool SmartTouch-SF) in 4 healthy adult swine in the presence or absence of IPF were examined. Ex vivo, RF was delivered at low (≤3 mL/min), reduced (5-7 mL/min), and high (≥10 mL/min) IFRs using intermediate (25-35 W) and high (35-45 W) power. In vivo, applications were delivered (at 9.3 ± 2.2 g for 60 seconds at 39 W) using reduced (5 mL/min) and high (15 mL/min) IFRs. RESULTS: Ex vivo, surface lesion diameter inversely correlated with IFR, whereas maximum lesion diameter and depth did not differ. While steam pops occurred more frequently at low IFR using high power (ThermoCool SmartTouch and ThermoCool SmartTouch-SF), tissue disruption was rare and did not vary with IFR. In vivo, charring/steam pop was not detected. Although there were no discernible differences in lesion size with IFR, surface lesion diameter, maximum diameter, depth, and volume were all smaller in the presence of IPF at both IFRs. CONCLUSION: Cooled-tip epicardial RF ablation created using reduced IFRs (5-7 mL/min) yields lesion sizes similar to those created using high IFRs (≥10 mL/min) without an increase in steam pop/tissue disruption, whereas the presence of IPF significantly reduces the lesion size.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Heart Ventricles/surgery , Pericardium/surgery , Therapeutic Irrigation/instrumentation , Animals , Atrial Fibrillation/physiopathology , Disease Models, Animal , Equipment Design , Heart Rate , Heart Ventricles/physiopathology , Swine
17.
J Cardiovasc Electrophysiol ; 27(7): 861-7, 2016 07.
Article in English | MEDLINE | ID: mdl-27062526

ABSTRACT

INTRODUCTION: There is a paucity of data on the mechanisms of cough and hemoptysis that sometimes ensue from cryoballoon ablation of pulmonary veins (Cryo-PV). This study specifically examined the impact of ultra-cold (≤-60 °C, 3 minutes), prolonged (>-55 °C, 6 minutes), and conventional (>-55 °C, 3 minutes) Cryo-PV on lung/bronchial injury. METHODS AND RESULTS: Four healthy adult swine underwent Cryo-PV. Each animal received Cryo-PV to the inferior common trunk and the right superior PV. In 2 animals, 1 PV was treated with 2 ultra-cold (Cryo-AUltra-cold ) and the other with 2 conventional (Cryo-AConventional ) cryoapplications. In the other 2 animals, 1 PV was ablated using 2 prolonged (Cryo-BProlonged ) and the other with 2 conventional (Cryo-BConventional ) applications. The nadir cryoballoon temperatures were lower in Cryo-AUltra-cold versus Cryo-AConventional (-66 ± 6 °C vs. -45 ± 5 °C; P = 0.001), but did not differ between Cryo-BProlonged and Cryo-BConventional (-46 ± 3 °C vs. -49 ± 3 °C; P = 0.123). Post-ablation bronchoscopy revealed immediate mucosal edema and erythema with/without bleeding in the adjacent bronchi in 100% of Cryo-AUltra-cold and 50% of Cryo-AConventional /Cryo-BConventional and Cryo-BProlonged . At 4 hours post-ablation, there were marked increases in bronchoalveolar macrophages (P <0.001), lymphocytes (P = 0.035) and neutrophils (P = 0.001). Furthermore, Cryo-AUltra-cold yielded the largest increase in the macrophage (P = 0.005) and neutrophil (P = 0.034) cell counts. While similar trends were seen in Cryo-BProlonged , these did not reach statistical significance. CONCLUSION: Cryo-PV can elicit acute bronchial inflammation, bleeding, and mucosal injury. While this was further augmented by ultra-cold cryoapplications, it was also evident to a lesser degree with prolonged and even conventional cryoapplications. The mechanism for this appears to be direct collateral injury.


Subject(s)
Bronchi/injuries , Cold Temperature/adverse effects , Cryosurgery/adverse effects , Lung Injury/etiology , Pulmonary Veins/surgery , Animals , Biopsy , Bronchi/diagnostic imaging , Bronchi/immunology , Bronchi/pathology , Bronchitis/etiology , Bronchoscopy , Chemotaxis, Leukocyte , Cryosurgery/methods , Hemorrhage/etiology , Lung Injury/diagnostic imaging , Lung Injury/immunology , Lung Injury/pathology , Lymphocytes/immunology , Macrophages/immunology , Models, Animal , Neutrophil Infiltration , Neutrophils/immunology , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/pathology , Respiratory Mucosa/immunology , Respiratory Mucosa/injuries , Respiratory Mucosa/pathology , Sus scrofa , Time Factors
18.
Heart Rhythm ; 13(2): 424-32, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26520204

ABSTRACT

BACKGROUND: Limited data exist on procedural and biophysical indicators of pulmonary vein (PV) isolation durability after the cryoballoon ablation of atrial fibrillation (AF). OBJECTIVE: The aim of this study was to investigate the procedural and biophysical characteristics associated with late PV reconnection (PVR) and durable PV isolation (PVI) after cryoablation using the currently available second-generation cryoballoon. METHODS: Data from 435 PVs targeted in 112 consecutive patients who underwent a repeat procedure 14 ± 3 months after an index cryoablation of AF were examined. RESULTS: Altogether, 111 PVs (25.5%) in 71 patients (63.4%) demonstrated PVR, whereas 324 PVs (74.5%) exhibited PVI. The number and duration of cryoballoon applications did not differ between PVR and PVI. However, the time to PV isolation (time to effect) was considerably shorter (39.1 ± 11.7 seconds vs 67.6 ± 19.7 seconds; P < .001), the balloon temperature at time to effect was significantly warmer (-32.1°C ± 7.8°C vs -39.4°C ± 5.8°C; P < .001), the balloon nadir temperature was slightly cooler (-48.7°C ± 4.6°C vs -47.8°C ± 2.9°C; P = .034), and the total thaw time (56.5 ± 25.4 seconds vs 34.8 ± 9.1 seconds; P < .001) and interval thaw times at 0°C (iTT0; 14.8 ± 10.9 seconds vs 7.1 ± 2.0 seconds; P < .001) and 15°C (54.2 ± 25.4 seconds vs 33.3 ± 9.1 seconds; P < .001) were notably longer with PVI than with PVR. However, only a time to effect of ≤60 seconds and an iTT0 of ≥10 seconds emerged as significant predictors of PV isolation durability. Consequently, in a multivariate model, presence of both criteria predicted <1% and their mere absence ~75% likelihood of PVR. CONCLUSION: A time to effect of ≤60 seconds and an iTT0 of ≥10 seconds significantly predict PV isolation durability after the cryoballoon ablation of AF. If both criteria are met, the likelihood of PV reconnection may be exceedingly low.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Intraoperative Care/methods , Postoperative Complications , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Clinical Protocols , Cryosurgery/adverse effects , Cryosurgery/instrumentation , Cryosurgery/methods , Equipment Design , Female , Humans , Male , Middle Aged , Operative Time , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Recurrence , Retrospective Studies , Time Factors , Treatment Outcome
20.
Heart Rhythm ; 12(7): 1431-7, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25998141

ABSTRACT

BACKGROUND: Surgical exclusion of the left atrial appendage (LAA) can frequently yield incomplete closure. OBJECTIVE: We evaluated the ischemic stroke/systemic embolization (SSE) risk in patients with atrial fibrillation (AF) and complete LAA closure (cLAA) vs incompletely surgically ligated LAA (ISLL) and LAA stump after surgical suture ligation. METHODS: Seventy-two patients (CHA2DS2-VASc score 4.1 ± 1.9) underwent surgical LAA ligation in conjunction with mitral valve/AF surgery and postoperative LAA evaluation using computerized tomographic angiography. RESULTS: Overall, cLAA was detected in 46 of 72 patients (64%), ISLL in 17 patients (24%), and LAA stump in 9 patients (12%). The incidences of oral anticoagulation (OAC) and recurrent AF were similar among the 3 groups during 44 ± 19 months of follow-up. SSE occurred in 2% of patients with cLAA vs 24% with ISLL and 0% with LAA stump (P = .006). None of the patients with SSE were receiving OAC, and all had recurrent AF during follow-up. Additionally, patients with SSE exhibited a significantly smaller ISLL neck diameter (2.8 ± 1.0 vs 7.1 ± 2.1 mm; P = .002). The annualized SSE risk was 1.9% (entire cohort), 6.5% (ISLL patients), 14.4% (ISLL patients not receiving OAC), and 19.0% (ISLL neck diameter ≤5.0 mm) per 100 patient-years of follow-up. The latter risk was nearly 5 times greater than predicted by conventional risk-stratification schemes. Moreover, ISLL emerged as an independent predictor of SSE in univariate analyses and as the sole predictor of SSE in a multivariate analysis. CONCLUSION: In patients with AF, ISLL is a predictor of SSE, independent of conventional risk stratification schemes. Consequently, OAC should be strongly considered in this high-risk cohort.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation , Cardiac Surgical Procedures , Postoperative Complications , Stroke , Thromboembolism , Aged , Aged, 80 and over , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Brazil , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/methods , Echocardiography, Transesophageal , Female , Follow-Up Studies , Humans , Ligation , Male , Middle Aged , Postoperative Complications/diagnosis , Postoperative Complications/prevention & control , Risk Assessment , Risk Factors , Stroke/diagnosis , Stroke/etiology , Stroke/prevention & control , Thromboembolism/diagnosis , Thromboembolism/etiology , Thromboembolism/prevention & control , Wound Closure Techniques/adverse effects