J Prosthet Dent ; 68(3): 537-41, 1992 Sep.
Article in English | MEDLINE | ID: mdl-1432777

ABSTRACT

The effect of transverse horizontal axis deviations on the vertical and horizontal orientation of maxillary and mandibular members was investigated on a laboratory articulator model. Twelve axis deviations (+30, +25, +20, +15, +10, +5, -5, -10, -15, -20, -25, and -30 mm groups) within a 55 mm dimension model were evaluated. Three trials at each transverse horizontal axis deviation demonstrated significant changes in maxillomandibular orientation after mounting the mandibular member with a standardized intermember mounting record. A linear regression analysis produced an equation for predictive interpolation of anterior-posterior shift as a result of axis deviations from +30 to -30 mm.


Subject(s)
Dental Articulators , Dental Occlusion, Centric , Analysis of Variance , Humans , Maxilla , Regression Analysis , Reproducibility of Results , Single-Blind Method , Vertical Dimension