Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 20(14): 15489-502, 2012 Jul 02.
Article in English | MEDLINE | ID: mdl-22772244

ABSTRACT

This paper presents experimental results from a pulsed quantum cascade laser based cavity ringdown spectrometer used as a high-throughput detection system. The results were obtained from an optical cavity with 99.8% input and output coupling mirrors that was rapidly swept (0.2s to 7s sweep times) between 1582.25 cm(-1) (6.3201µm) and 1697.00 cm(-1) (5.8928µm). The spectrometer was able to monitor gas species over the pressure range 585 torr to 1µtorr, and the analysis involves a new digital data processing system that optimises the processing speed and minimises the data storage requirements. In this approach we show that is it not necessary to make direct measurements of the ringdown time of the cavity to obtain the system dynamics. Furthermore, we show that correct data processing is crucial for the ultimate implementation of a wideband IR spectrometer that covers a range similar to that of commercial Fourier transform infrared instruments.

2.
Opt Express ; 20(8): 8804-14, 2012 Apr 09.
Article in English | MEDLINE | ID: mdl-22513591

ABSTRACT

This paper presents results from a pulsed-laser cavity ring-down spectrometer with novel field programable gate array real-time data collection. We show both theoretically and experimentally that the data extraction can be achieved from a single cavity ringdown event, and that the absorbance can be determined without the need to fit the ringdown time explicitly. This methodology could potentially provide data acquisition rate up to 1 MHz, with the accuracy and precision comparable to nonlinear least squares fitting algorithms.

3.
Opt Express ; 19(9): 8092-101, 2011 Apr 25.
Article in English | MEDLINE | ID: mdl-21643059

ABSTRACT

In this paper we report on the development of a Fourier-transform based signal processing method for laser-locked Continuous Wave Cavity Ringdown Spectroscopy (CWCRDS). Rather than analysing single ringdowns, as is the norm in traditional methods, we amplitude modulate the incident light, and analyse the entire waveform output of the optical cavity; our method has more in common with Cavity Attenuated Phase Shift Spectroscopy than with traditional data analysis methods. We have compared our method to Levenburg-Marquardt non linear least squares fitting, and have found that, for signals with a noise level typical of that from a locked CWCRDS instrument, our method has a comparable accuracy and comparable or higher precision. Moreover, the analysis time is approximately 500 times faster (normalised to the same number of time domain points). Our method allows us to analyse any number of periods of the ringdown waveform at once: this allows the method to be optimised for speed and precision for a given spectrometer.


Subject(s)
Algorithms , Lasers , Spectrum Analysis/instrumentation , Spectrum Analysis/methods , Fourier Analysis
4.
J Colloid Interface Sci ; 316(1): 59-65, 2007 Dec 01.
Article in English | MEDLINE | ID: mdl-17854819

ABSTRACT

Oil droplets dispersed in water can be readily studied when they are coated with surfactants, which lower their interfacial tension and enhance their stability. Pure oil droplets are more difficult to study because of their high interfacial tension, which facilitates coalescence and the adsorption of contaminants. In this study, we have characterised the surface charging properties of a water insoluble oil, bromododecane, which has a density close to water. The small density difference allows us to study relatively large drops of this oil and to analyse its coalescence behaviour. The results obtained with this simple, surfactant-free, system suggest that an additional attractive force, such as the long range hydrophobic interaction, might be required to explain oil droplet coalescence behaviour.

SELECTION OF CITATIONS
SEARCH DETAIL
...