Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Lab Med ; 55(2): 162-168, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-37294928

ABSTRACT

OBJECTIVE: To investigate the association of immune response with vaccination adverse effects at peak anti-receptor-binding domain spike subunit 1 (anti-RBDS1) IgG after full vaccination with Comirnaty, Spikevax, or Vaxzevria. METHODS: Anti-RBDS1 IgG concentrations after vaccination were determined in healthy adults vaccinated with the Comirnaty, Spikevax, and Vaxzevria vaccines. The association of reactogenicity and peak antibody response after vaccination was tested. RESULTS: Anti-RBDS1 IgG values were significantly higher in the Comirnaty and Spikevax group, compared with the Vaxzevria group (P < .001). Fever and muscle pain were found to be significant independent predictors of peak anti-RBDS1 IgG in the Comirnaty and Spikevax groups (P = .03 and P = .02, respectively). The multivariate model, adjusted for covariates, showed that no association between reactogenicity and peak antibody concentrations was found in the Comirnaty, Spikevax, and Vaxzevria groups. CONCLUSIONS: No association between reactogenicity and peak anti-RBDS1 IgG after vaccination with the Comirnaty, Spikevax, and Vaxzevria vaccine was found.


Subject(s)
COVID-19 Vaccines , COVID-19 , Immunogenicity, Vaccine , Immunoglobulin G , Adult , Humans , 2019-nCoV Vaccine mRNA-1273 , BNT162 Vaccine , ChAdOx1 nCoV-19 , COVID-19/prevention & control , COVID-19 Vaccines/immunology
2.
Biochem Med (Zagreb) ; 30(3): 030501, 2020 Oct 15.
Article in English | MEDLINE | ID: mdl-32774119

ABSTRACT

Joint diseases are conditions with an often progressive and generally painful nature affecting the patient's quality of life and, in some cases, requiring a prompt diagnosis in order to start the treatment urgently. Synovial fluid (SF) laboratory testing is an important part of a diagnostic evaluation of patients with joint diseases. Laboratory testing of SF can provide valuable information in establishing the diagnosis, be a part of a patient's follow-up and treatment with the purpose of improving the patient's health and quality of life. Synovial fluid laboratory testing is rarely performed in Croatian medical biochemistry laboratories. Consequently, procedures for SF laboratory testing are poorly harmonized. This document is the second in the series of recommendations prepared by the members of the Working group for extravascular body fluid samples of the Croatian Society of Medical Biochemistry and Laboratory Medicine. It addresses preanalytical, analytical, and postanalytical issues and the clinical significance of tests used in SF laboratory testing with the aim of improving the value of SF laboratory testing in the diagnosis of joint diseases and assisting in the achievement of national harmonization. It is intended for laboratory professionals and all medical personnel involved in synovial fluid collection and testing.


Subject(s)
Clinical Laboratory Techniques/standards , Specimen Handling/standards , Synovial Fluid/metabolism , Gout/diagnosis , Humans , Osteoarthritis/diagnosis , Pre-Analytical Phase/standards , Quality Control , Reference Values , Societies, Medical , Specimen Handling/methods , Synovial Fluid/chemistry , Synovial Fluid/cytology
3.
Biochem Med (Zagreb) ; 30(2): 020701, 2020 Jun 15.
Article in English | MEDLINE | ID: mdl-32292279

ABSTRACT

INTRODUCTION: Our aim was to investigate the stability of clinically relevant analytes in pleural and peritoneal fluids stored in variable time periods and variable storage temperatures prior to analysis. MATERIALS AND METHODS: Baseline total proteins (TP), albumin (ALB), lactate dehydrogenase (LD), cholesterol (CHOL), triglycerides (TRIG), creatinine (CREA), urea, glucose and amylase (AMY) were measured using standard methods in residual samples from 29 pleural and 12 peritoneal fluids referred to our laboratory. Aliquots were stored for 6 hours at room temperature (RT); 3, 7, 14 and 30 days at - 20°C. At the end of each storage period, all analytes were re-measured. Deviations were calculated and compared to stability limits (SL). RESULTS: Pleural fluid TP and CHOL did not differ in the observed storage periods (P = 0.265 and P = 0.170, respectively). Statistically significant differences were found for ALB, LD, TRIG, CREA, urea, glucose and AMY. Peritoneal fluid TP, ALB, TRIG, urea and AMY were not statistically different after storage, contrary to LD, CHOL, CREA and glucose. Deviations for TP, ALB, CHOL, TRIG, CREA, urea and AMY in all storage periods tested for both serous fluids were within the SL. Deviations exceeding SL were observed for LD and glucose when stored for 3 and 7 days at - 20°C, respectively. CONCLUSIONS: TP, ALB, CHOL, TRIG, CREA, urea and AMY are stable in serous samples stored up to 6 hours at RT and/or 30 days at - 20°C. Glucose is stable up to 6 hours at RT and 3 days at - 20°C. The stability of LD in is limited to 6 hours at RT.


Subject(s)
Ascitic Fluid/chemistry , Blood Chemical Analysis/standards , Chemistry, Clinical/standards , Pleural Effusion/blood , Aged , Aged, 80 and over , Blood Specimen Collection/standards , Female , Humans , Male , Middle Aged , Time Factors
4.
Biochem Med (Zagreb) ; 30(1): 010502, 2020 Feb 15.
Article in English | MEDLINE | ID: mdl-31839720

ABSTRACT

Extravascular body fluids (EBF) analysis can provide useful information in the differential diagnosis of conditions that caused their accumulation. Their unique nature and particular requirements accompanying EBF analysis need to be recognized in order to minimize possible negative implications on patient safety. This recommendation was prepared by the members of the Working group for extravascular body fluid samples (WG EBFS). It is designed to address the total testing process and clinical significance of tests used in EBF analysis. The recommendation begins with a chapter addressing validation of methods used in EBF analysis, and continues with specific recommendations for serous fluids analysis. It is organized in sections referring to the preanalytical, analytical and postanalytical phase with specific recommendations presented in boxes. Its main goal is to assist in the attainment of national harmonization of serous fluid analysis and ultimately improve patient safety and healthcare outcomes. This recommendation is intended to all laboratory professionals performing EBF analysis and healthcare professionals involved in EBF collection and processing. Cytological and microbiological evaluations of EBF are beyond the scope of this document.


Subject(s)
Body Fluids/chemistry , Clinical Laboratory Techniques/standards , Body Fluids/metabolism , Exudates and Transudates/chemistry , Exudates and Transudates/metabolism , Guidelines as Topic , Humans , Patient Safety , Pleural Effusion/diagnosis , Quality Assurance, Health Care , Societies, Medical , Specimen Handling/standards
5.
Biochem Med (Zagreb) ; 26(3): 395-407, 2016 Oct 15.
Article in English | MEDLINE | ID: mdl-27812307

ABSTRACT

INTRODUCTION: We hypothesized that extravascular body fluid (EBF) analysis in Croatia is not harmonized and aimed to investigate preanalytical, analytical and postanalytical procedures used in EBF analysis in order to identify key aspects that should be addressed in future harmonization attempts. MATERIALS AND METHODS: An anonymous online survey created to explore laboratory testing of EBF was sent to secondary, tertiary and private health care Medical Biochemistry Laboratories (MBLs) in Croatia. Statements were designed to address preanalytical, analytical and postanalytical procedures of cerebrospinal, pleural, peritoneal (ascites), pericardial, seminal, synovial, amniotic fluid and sweat. Participants were asked to declare the strength of agreement with proposed statements using a Likert scale. Mean scores for corresponding separate statements divided according to health care setting were calculated and compared. RESULTS: The survey response rate was 0.64 (58 / 90). None of the participating private MBLs declared to analyse EBF. We report a mean score of 3.45 obtained for all statements evaluated. Deviations from desirable procedures were demonstrated in all EBF testing phases. Minor differences in procedures used for EBF analysis comparing secondary and tertiary health care MBLs were found. The lowest scores were obtained for statements regarding quality control procedures in EBF analysis, participation in proficiency testing programmes and provision of interpretative comments on EBF's test reports. CONCLUSIONS: Although good laboratory EBF practice is present in Croatia, procedures for EBF analysis should be further harmonized to improve the quality of EBF testing and patient safety.


Subject(s)
Body Fluids/chemistry , Laboratories , Croatia , Humans , Societies, Medical , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...