Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Sci Pollut Res Int ; 31(7): 10920-10933, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38216815

ABSTRACT

This study established the simultaneous determination of the selected endocrine-disrupting compounds (EDCs) and pesticides in rock, soil, water, moss, and feces samples collected from the Antarctic region. The spray-assisted droplet formation-based liquid phase microextraction (SADF-LPME) coupled to GC-MS system was developed and validated for the screening and monitoring of 29 selected EDCs and pesticides. Binary solvent system, 1:1 (v/v) dichlormethane: 1,2-dichloroethane mixture was employed as an extraction solvent and sprayed onto sample or standard solutions using a straightforward and practical spray apparatus. The factors affecting the extraction process such as extraction solvent type and ratio, extraction solvent volume (spray repetition), vortexing period, and sample pH were properly optimized. Analytical figures of the merit of the method were recorded under the optimal extraction/chromatographic conditions. The LOD, LOQ, and enhancement factor were in the range of 1.0 to 6.6 ng/g, 3.2 to 22.1 ng/g, and 3.7 to 158.9, respectively. The method demonstrated a good linear working range for all the selected analytes with proper coefficients of determination. The usability and reliability of the microextraction strategy was confirmed using seawater, moss, and soil samples, and the %recoveries were within an acceptable range (> 70%) for all examined samples. The environmental samples collected from the Horseshoe and Faure Islands of the Antarctica region were analyzed to assess the potential pollution of EDCs and pesticides. This method has the potential to be employed for the analysis of EDCs in routine analytical laboratories and for controlling and screening the organic pollutant content of different environmental samples.


Subject(s)
Endocrine Disruptors , Liquid Phase Microextraction , Pesticides , Water/chemistry , Gas Chromatography-Mass Spectrometry/methods , Pesticides/analysis , Endocrine Disruptors/analysis , Antarctic Regions , Liquid Phase Microextraction/methods , Reproducibility of Results , Soil , Solvents/chemistry
2.
Environ Monit Assess ; 196(1): 77, 2023 Dec 22.
Article in English | MEDLINE | ID: mdl-38135867

ABSTRACT

This study employed simple polystyrene-coated magnetite nanoparticles (PS@MNPs)-assisted batch adsorption process for the removal of two antidepressant active ingredients (amitriptyline HCl and sertraline HCl) from hospital wastewater. Dominant parameters of the adsorption process including pH, adsorbent amount, and contact period were optimized through the univariate approach to enhance the adsorption efficiency. Upon reaching optimum adsorption conditions, equilibrium experiments were performed by spiking the adsorbates in hospital wastewater in the concentration range of 100-2000 µg/L. The concentrations of the adsorbates in the effluent were calculated using the matrix-matching calibration strategy to enhance the accuracy of quantification. A validated switchable solvent-based liquid phase microextraction (SS-LPME) method was employed to enrich the two active pharmaceutical ingredients (APIs) prior to sensitive determination with GC-MS (gas chromatography-mass spectrometry). The equilibrium data were mathematically modeled employing the Langmuir and Freundlich adsorption isotherm models. The isotherm constants were calculated, and the results showed that both the isotherm models fitted well with the experimental data. The efficient and simple batch adsorption strategy reported in this study was successfully employed to remove amitriptyline HCl and sertraline HCl from hospital wastewater at low concentrations.


Subject(s)
Magnetite Nanoparticles , Water Pollutants, Chemical , Amitriptyline/analysis , Wastewater , Bulk Drugs , Polystyrenes/analysis , Sertraline/analysis , Adsorption , Magnetite Nanoparticles/chemistry , Environmental Monitoring , Antidepressive Agents/analysis , Water Pollutants, Chemical/analysis , Kinetics , Hydrogen-Ion Concentration
3.
Environ Monit Assess ; 195(11): 1358, 2023 Oct 23.
Article in English | MEDLINE | ID: mdl-37870665

ABSTRACT

In this study, detection sensitivity of the conventional flame atomic absorption spectrophotometer (FAAS) for the determination of manganese (Mn2+) was enhanced by employing a preconcentration method from wastewater samples. Flower-shaped Ni(OH)2 nanomaterials were synthesized and used as sorbent material in preconcentration procedure. With the aim of attaining optimum experimental conditions, effective parameters of extraction method were optimized and these included pH of buffer solution, desorption solvent concentration and volume, mixing type and period, nanoflower amount, and sample volume. The detection limit of the optimized method was determined to be 2.2 µg L-1, and this correlated to about 41-fold enhancement in detection power relative to direct FAAS measurement. Domestic wastewater was used to test the feasibility of the proposed method to real samples by performing spike recovery experiments. The wastewater sample was spiked at four different concentrations of manganese, and the percent recoveries determined were in the range of 95-120%.


Subject(s)
Manganese , Nickel , Nickel/analysis , Manganese/analysis , Wastewater , Environmental Monitoring/methods , Solvents , Spectrophotometry, Atomic/methods
4.
Anal Sci ; 38(6): 843-849, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35347676

ABSTRACT

A sensitive, accurate and simple analytical method was developed to determine cadmium by slotted quartz tube-flame atomic absorption spectrometry after preconcentration/extraction with polystyrene coated magnetic nanoparticles based dispersive solid phase extraction. The surface of Fe3O4 based magnetic nanoparticles was modified with polystyrene to yield higher selectivity and sensitivity in adsorption efficiency of cadmium. The nanoparticles were dispersed into the aqueous solution to extract/separate cadmium. Significant parameters of the method including magnetic nanoparticle amount, mixing effect, effect of ionic strength, eluent concentration and sonication period were optimized to achieve optimal conditions for the analyte. The limit of detection and quantification values of the developed method were found to be 0.62 and 2.1 ng/mL, respectively. Under the optimum conditions, enhancement of the detection power for cadmium were calculated as 102 folds for the developed method. The developed method was then applied to cigarette ash to test its accuracy and applicability. Total cadmium was found to be between 402 and 450 ng/g in the ashes of different cigarette brands commercially available in Turkey. The accuracy of quantifying cadmium in the complex ash samples was enhanced by using the matrix matching calibration strategy. The developed method provides sensitive and selective determination of cadmium at ng/mL levels even at complex cigarette ash samples. High percent recovery results (90-102%) were obtained from spiked real samples.


Subject(s)
Magnetite Nanoparticles , Tobacco Products , Water Pollutants, Chemical , Cadmium/analysis , Limit of Detection , Magnetite Nanoparticles/chemistry , Polystyrenes , Quartz/chemistry , Solid Phase Extraction/methods , Spectrophotometry, Atomic/methods , Tobacco Products/analysis , Water Pollutants, Chemical/analysis
5.
Water Sci Technol ; 85(1): 220-228, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35050878

ABSTRACT

In this study, seven compounds of environmental and health concern were treated by electrooxidation to determine their removal efficiencies from domestic wastewater. A batch type lab-scale reactor was used for the treatment process, and the analytes studied included two obsolete pesticides, two alkylphenols, two hormones, and bisphenol A. Titanium oxide and graphite electrodes were used as anode and cathode, respectively. Parameters of the electrooxidation process including pH of wastewater, ionic strength, applied current and treatment period were optimized by the univariate approach to maximize the removal efficiency of the analytes from wastewater. The optimum conditions were determined as nonadjusted pH of wastewater, 1.5 A current, 15 min treatment period and 5.0 g/L sodium chloride. Dispersive liquid-liquid microextraction was used to preconcentrate analytes before and after treatment in order to calculate the removal efficiency of analytes. The removal efficiency obtained under the optimum conditions was satisfactory for all seven analytes at different influent concentrations.


Subject(s)
Pesticides , Water Pollutants, Chemical , Benzhydryl Compounds , Hormones , Pesticides/analysis , Phenols , Wastewater , Water Pollutants, Chemical/analysis
6.
Environ Monit Assess ; 194(2): 58, 2022 Jan 06.
Article in English | MEDLINE | ID: mdl-34989878

ABSTRACT

This study utilized switchable solvent liquid-phase microextraction (SS-LPME) to enrich eleven nervous system active pharmaceutical ingredients (APIs) from aqueous samples for their determination at trace levels by gas chromatography mass spectrometry. The analytes selected for the study included APIs utilized in antidepressant, antipsychotic, antiepileptic, and anti-dementia drugs. Parameters of the microextraction method including switchable solvent volume, concentration and volume of the trigger agent (sodium hydroxide), and sample agitation period were optimized univariately to boost extraction efficiency. Under the optimum conditions, the detection limits calculated for the analytes were in the range of 0.20-8.0 ng/mL, and repeatability for six replicate measurements as indicated by percent relative standard deviation values were below 10%. Matrix matching calibration strategy was used to enhance quantification accuracy for the analytes. The percent recovery results calculated for the eleven analytes ranged between 86 and 117%.


Subject(s)
Liquid Phase Microextraction , Pharmaceutical Preparations , Water Pollutants, Chemical , Calibration , Environmental Monitoring , Gas Chromatography-Mass Spectrometry , Limit of Detection , Nervous System/chemistry , Solvents , Water Pollutants, Chemical/analysis
7.
Anal Biochem ; 629: 114309, 2021 09 15.
Article in English | MEDLINE | ID: mdl-34270997

ABSTRACT

This study presents a Fenton digestion method for milk samples based on UV irradiation for cadmium determination using flame atomic absorption spectrometry. The method was developed as an alternative to microwave digesters, using very basic apparatus and easy to acquire chemicals. Fenton digestion process was performed by the help of citric acid coated magnetic nanoparticles. Optimum conditions of the digestion process were applied to milk samples to evaluate analytical performance of the method. Limit of detection and limit of quantification values calculated for cadmium in milk were 0.53 and 1.8 mg/L, respectively. The method was applied to three different milk samples to validate the method's suitability and accuracy. Percent recovery values calculated for the samples spiked at two different concentrations ranged between 86 and 111%. Due to differences in the content of the spiked and control/standard milk samples, exact matrix matching calibration strategy using the same brand of milk sample in the preparation of calibration standard was employed and the accuracy of cadmium quantification was greatly enhanced (≈100%).


Subject(s)
Cadmium/analysis , Hydrogen Peroxide/chemistry , Iron/chemistry , Magnetite Nanoparticles/chemistry , Milk/chemistry , Animals , Digestion , Limit of Detection , Microwaves , Oxidation-Reduction , Spectrophotometry, Atomic
8.
Environ Monit Assess ; 192(5): 275, 2020 Apr 08.
Article in English | MEDLINE | ID: mdl-32270289

ABSTRACT

In this study, a switchable solvent-based liquid-phase microextraction method was developed to preconcentrate selected pesticides from tap water and wastewater matrices for determination by gas chromatography-mass spectrometry. A thorough optimization process was performed for prominent extraction parameters such as switchable solvent amount, concentration/amount of sodium hydroxide, salt type and mixing period. Optimum parameters obtained at the end of the optimization process were applied to aqueous standard solutions to validate the method. The linear dynamic ranges of all four analytes were appreciably wide with coefficient of determination values greater than 0.9997. The limits of detection and quantification (LOD and LOQ) were calculated for the analytes in the ranges of 0.38-2.0 ng/mL and 1.3-6.5 ng/mL, respectively. Spiked recovery experiments were used to validate the accuracy of the developed method and to determine the performance of the method in different sample matrices. Tap water, municipal wastewater and medical wastewater were spiked at three different concentrations and analyzed under the method's optimum conditions. The percent recovery results calculated for the samples were in the range of 79-107%, and this validated the method's accuracy and applicability to complex matrices such as municipal and medical wastewater samples.


Subject(s)
Environmental Monitoring , Herbicides , Insecticides , Liquid Phase Microextraction , Water Pollutants, Chemical , Environmental Monitoring/instrumentation , Gas Chromatography-Mass Spectrometry , Limit of Detection , Solvents , Wastewater
9.
J AOAC Int ; 2020 Jun 17.
Article in English | MEDLINE | ID: mdl-34582558

ABSTRACT

A multivariate experimental design was used to attain optimum conditions of a dispersive liquid-liquid microextraction (DLLME) method for preconcentration of pesticides and pharmaceuticals for determination by gas chromatography mass spectrometry (GC-MS). Experimental design enabled parameters to be evaluated for their effects on extraction output as well as their interactive effects. The optimum parameters suggested by the design model were 200 µL of chloroform, 1.96 mL of ethanol and 40 s vortexing period. Limits of detection and quantification (LOD and LOQ) were calculated using linear calibration plots of the analytes developed in the standard concentration range of 2.0 µg/L-2.0 mg/L. Enhancement in detection power of the analytes recorded by the optimized method with respect to direct GC-MS determination (based on LOD values) was in the range of 3.6 and 539 folds. Spiked recovery experiments for municipal, medical and synthetic wastewater samples yielded low recovery results when calculated against aqueous standard solutions. Matrix matched calibration standards were used to mitigate interferences from the waste samples, and the percent recoveries obtained were close to 100%. This established accuracy and applicability of the developed method.

SELECTION OF CITATIONS
SEARCH DETAIL
...