Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Sci Rep ; 12(1): 14911, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36050354

ABSTRACT

Transcutaneous medium-frequency alternating electrical current is defined as an alternating current between 1 and 10 kHz and is capable of producing an instant, reversible block. This study aims to evaluate the efficacy of sensory perception and force production of the index and middle finger after transcutaneous medium-frequency alternating electrical current stimulation of the distal median nerve. A single-center prospective interventional cohort study was conducted in adult healthy volunteers at the Jessa Hospital, Hasselt, Belgium. Two different electrodes (PALS & 3M) were placed on the distal median nerve, which was located using a Sonosite X-Porte Ultrasound transducer, with the first electrode being placed on the skin at the level of the transverse carpal ligament and the second electrode 7 cm proximally to the first electrode. The tactile sensation was evaluated with Semmes-Weinstein monofilament test and sensation of pressure/pain was evaluated with an algometer. Peak force production was assessed with an electronic dynamometer. All measurements were performed at baseline and tMFAEC stimulation frequencies of 2 and 10 kHz in a randomized manner. Statistical analysis was performed with a one-way ANOVA with repeated measures test or a Friedman rank sum test, followed by the Wilcoxon signed rank test adjusted with Bonferroni correction. A p-value < 0.05 was considered statistically significant. From 9 to 13th of April 2021, 25 healthy volunteers were included in the Jessa Hospital, Hasselt, Belgium. A statistically significant reduction in tactile sensation during 2 kHz and 10 kHz stimulation compared to baseline was observed (2.89 ± 0.22 (PALS2); 3.35 ± 0.25 (3M2) and 2.14 ± 0.12 (PALS10); 2.38 ± 0.12 (3M10) versus - 1.75 ± 0.09 (baseline), p < 0.0001). 3M electrodes showed a tendency towards the elevation of pressure pain threshold compared to baseline. No significant difference in mean peak forces of the index and middle fingers after transcutaneous medium-frequency alternating electrical current stimulation with 2 and 10 kHz was found. This study demonstrates that transcutaneous medium-frequency alternating electrical current stimulation on the distal median nerve inhibits tactile sensory nerve activity in the index and middle finger when stimulation of 2 kHz and, to a lesser extent, 10 kHz was applied. A reduction of motor nerve activity was not observed but force production measurements may be prone to error.Trial registration: clinicaltrials.gov on 01/04/2021. NCT-Number: NCT04827173.


Subject(s)
Transcutaneous Electric Nerve Stimulation , Adult , Cohort Studies , Humans , Median Nerve/physiology , Pain , Pain Threshold/physiology , Prospective Studies
2.
Ann Med ; 53(1): 337-344, 2021 12.
Article in English | MEDLINE | ID: mdl-33583292

ABSTRACT

BACKGROUND: To minimise the risk of COVID-19 transmission, an ambulant screening protocol for COVID-19 in patients before admission to the hospital was implemented, combining the SARS CoV-2 reverse-transcriptase polymerase chain reaction (RT-PCR) on a nasopharyngeal swab, a chest computed tomography (CT) and assessment of clinical symptoms. The aim of this study was to evaluatethe diagnostic yield and the proportionality of this pre-procedural screeningprotocol. METHODS: In this mono-centre, prospective, cross-sectional study, all patients admitted to the hospital between 22nd April 2020 until 14th May 2020 for semi-urgent surgery, haematological or oncological treatment, or electrophysiological investigationunderwent a COVID-19 screening 2 days before their procedure. At a 2-week follow-up, the presence of clinical symptoms was evaluated by telephone as a post-hoc evaluation of the screening approach.Combined positive RT-PCR assay and/or positive chest CT was used as gold standard. Post-procedural outcomes of all patients diagnosed positive for COVID-19 were assessed. RESULTS: In total,528 patients were included of which 20 (3.8%) were diagnosed as COVID-19 positive and 508 (96.2%) as COVID-19 negative. 11 (55.0%) of COVID-19 positive patients had only a positive RT-PCR assay, 3 (15.0%) had only a positive chest CT and 6 (30%) had both a positive RT-PCR assay and chest CT. 10 out of 20 (50.0%) COVID-19 positive patients reported no single clinical symptom at the screening. At 2 week follow-up, 50% of these patients were still asymptomatic. 37.5% of all COVID-19 negative patients were symptomatic at screening. In the COVID-19 negative group without symptoms at screening, 78 (29.3%) patients developed clinical symptoms at a 2-week follow-up. CONCLUSION: This study suggests that routine chest CT and assessment of self-reported symptoms have limited value in the preprocedural COVID-19 screening due to low sensitivity and/or specificity.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , Mass Screening/methods , Patient Admission , Adult , Aged , COVID-19/epidemiology , Cross-Sectional Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Reverse Transcriptase Polymerase Chain Reaction , Sensitivity and Specificity , Tomography, X-Ray Computed
3.
PLoS One ; 16(1): e0245774, 2021.
Article in English | MEDLINE | ID: mdl-33497408

ABSTRACT

BACKGROUND/OBJECTIVES: This study aimed to study one-month recovery profile and to identify predictors of Quality of Recovery (QOR) after painful day surgery and investigate the influence of pain therapy on QOR. METHODS/DESIGN: This is a secondary analysis of a single-centre, randomised controlled trial of 200 patients undergoing ambulatory haemorrhoid surgery, arthroscopic shoulder or knee surgery, or inguinal hernia repair between January 2016 and March 2017. Primary endpoints were one-month recovery profile and prevalence of poor/good QOR measured by the Functional Recovery Index (FRI), the Global Surgical Recovery index and the EuroQol questionnaire at postoperative day (POD) 1 to 4, 7, 14 and 28. Multiple logistic regression analysis was performed to determine predictors of QOR at POD 7, 14, and 28. Differences in QOR between pain treatment groups were analysed using the Mann-Whitney U test. RESULTS: Four weeks after haemorrhoid surgery, inguinal hernia repair, arthroscopic knee and arthroscopic shoulder surgery, good QOR was present in 71%, 76%, 57% and 24% respectively. Poor QOR was present in 5%, 0%, 7% and 29%, respectively. At POD 7 and POD 28, predictors for poor/intermediate QOR were type of surgery and a high postoperative pain level at POD 4. Male gender was another predictor at POD 7. Female gender and having a paid job were also predictors at POD 28. Type of surgery and long term fear of surgery were predictors at POD 14. No significant differences in total FRI scores were found between the two different pain treatment groups. CONCLUSIONS: The present study shows a procedure-specific variation in recovery profile in the 4-week period after painful day surgery. The best predictors for short-term (POD 7) and long-term (POD 28) poor/intermediate QOR were a high postoperative pain level at POD 4 and type of surgery. Different pain treatment regimens did not result in differences in recovery profile. TRIAL REGISTRATION: European Union Clinical Trials Register 2015-003987-35.


Subject(s)
Ambulatory Surgical Procedures/adverse effects , Elective Surgical Procedures/adverse effects , Pain, Postoperative/epidemiology , Patient Reported Outcome Measures , Adult , Aged , Ambulatory Surgical Procedures/standards , Elective Surgical Procedures/standards , Female , Humans , Male , Middle Aged , Pain, Postoperative/psychology , Patient Satisfaction
SELECTION OF CITATIONS
SEARCH DETAIL
...