Appl Radiat Isot ; 181: 110095, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34999307

ABSTRACT

This study discusses a computer simulation for the equivalent ambient dose due to photons, H*(10)p, and neutrons, H*(10)n, in the patient's plane undergoing radiation therapy. A standard radiotherapy room with an additional shielding made by one lead or steel tenth-value layer was considered. A Varian 2100/2300 C/D linear accelerator head operating at 18 MV was modeled. Jaw openings of 5 cm × 5 cm, 10 cm × 10 cm, 20 cm × 20 cm, and 30 cm × 30 cm, as well as the multileaf collimator under eight different angles of gantry inclination, were also modeled. The use of steel in the shield generates a slightly raised average value of H*(10)p (0.527%) compared to when using lead. This finding can be interpreted as that the use of lead or steel coating makes no difference to the additional shield calculations when only photons are considered. When considering the contribution to H*(10)n, there is a significant difference (11.7% increase) for using lead compared to steel shielding.


Subject(s)
Radiation Protection/methods , Radiotherapy Dosage , Computer Simulation , Humans , Monte Carlo Method , Neutrons , Particle Accelerators , Photons , Radiometry/methods
2.
Appl Radiat Isot ; 178: 109967, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34600284

ABSTRACT

This study focusses on the risk of potential exposure to radiation for personnel driving a truck as well as illegal individuals being transported in cargo containers. Inspection facilities usually use a high energy linear accelerator (linac) in order to inspect the cargo. Since this type of equipment has associated health risks due to potential unwanted exposure, the occupational and public dose limits should be calculated in order to develop safer work conditions. This work used a computation model running the code MCNPX to simulate a typical cargo inspection facility which used a linac operating at 4.5 MeV. Two scenarios were considered: (1) exposure of the driver to the primary beam due to a potential failure of the safety sensors; and (2) dose received by an illegal individual being transported inside the cargo container. The results show a dose of 0.8514 mSv per scan for the driver exposed to the primary X-ray beam, and 0.1997 mSv per scan for an individual transported in the cargo box. In conclusion, both the individual and the driver received a dose below the acceptable limit considered safe for an individual (1 mSv/year). However, that was the value of one scan; in a case in which multiple scans would be performed, the dose limit can be quickly exceeded. In that case, the limit would be exceeded by the driver faster than by the individual in the cargo.

3.
Appl Radiat Isot ; 165: 109332, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32739795

ABSTRACT

The Nuclear Engineering Department of the Military Institute of Engineering (SE/7-IME) is designing and simulation a neutron irradiator with 1 Ci of 241Am-9Be source. The objective of this irradiator is to generate a flux of neutrons to be used in research and teaching maintaining, for purposes of radiological protection, the rate of ambient dose equivalent, H*(10), below 10 µSv/h at 30 cm from the surface. This paper presents the proposed irradiator, values of H*(10) at different distances from the irradiator and the neutron flux in different points of the beam irradiation, all calculated using the MCNPX code.

4.
Appl Radiat Isot ; 163: 109163, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32561036

ABSTRACT

Medical linear accelerators (linacs) require a physical structure designed to provide adequate structural support which ensures the safety of patients, operators and the general public. During a radiotherapy session, healthy tissues are exposed to radiation, even with these safety guarantees. This unwanted exposure may increase the likelihood of developing secondary cancer. This work uses the MCNP-5 code to computationally simulate a conformational 3D radiotherapy protocol for prostate cancer. Also, it investigates the potential effects of radiotherapy room shielding composition on equivalent and effective doses in the patient's body. A computational model of an actual room was developed considering a Varian Trilogy linac operating at 10 MeV. This model enabled dose calculations for an anthropomorphic phantom called REX to be performed. This phantom has sufficient details of all relevant organs and tissues needed to estimate the effective dose of the patient. The treatment protocol modeled in this study came from the database of patients treated by the Brazilian National Cancer Institute (Inca). For this protocol, the total dose to be applied to the patient is equally distributed over the four gantry inclination angles (0°, 90°, 180° and 270°). The simulated results suggested that the equivalent dose on different organs and tissues has been increased by concrete shielding. Regarding the effective dose due to the presence of additional shielding (steel or lead), the simulation suggests that such variations can be considered small. Overall the results allowed quantifying the specific contribution of concrete, lead, and steel as part of shielding on the equivalent and effective doses in the patient.


Subject(s)
Prostatic Neoplasms/radiotherapy , Radiation Protection/instrumentation , Radiotherapy Dosage , Humans , Male , Phantoms, Imaging