Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
Mater Sci Eng C Mater Biol Appl ; 75: 95-103, 2017 Jun 01.
Article in English | MEDLINE | ID: mdl-28415551

ABSTRACT

The main aim of this study was to investigate the properties of an AZ91 alloy coated with nanostructured hydroxyapatite (HA) prepared by radio frequency (RF) magnetron sputtering. The bioactivity and biomineralization of the AZ91 magnesium alloy coated with HA were investigated in simulated body fluid (SBF) via an in vitro test. Scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, and X-ray diffraction (XRD) analyses were performed. The samples were immersed in SBF to study the ability of the surface to promote the formation of an apatite layer as well as corrosion resistance and mass change of the HA-coated AZ91 alloy. Electrochemical tests were performed to estimate the corrosion behaviour of HA-coated and uncoated samples. The results revealed the capability of the HA coating to significantly improve the corrosion resistance of the uncoated AZ91 alloy.


Subject(s)
Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Durapatite/chemistry , Magnesium/chemistry , Nanostructures/chemistry , Corrosion
2.
J Mech Behav Biomed Mater ; 63: 314-325, 2016 10.
Article in English | MEDLINE | ID: mdl-27450034

ABSTRACT

The hydroxyapatite enriched with Ti were prepared as possible candidates for biomedical applications especially for implantable devices that are in direct contact to the bone. The hydroxyapatites with different Ti content were prepared by RF magnetron sputtering on Ti-6Al-4V alloy using pure hydroxyapatite and TiO2 targets. The content of Ti was modified by changing the RF power fed on TiO2 target. The XPS and FTIR analyses revealed the presence of hydroxyapatite structure. The hardness and elastic modulus of the hydroxyapatite were increased by Ti addition. After 5 days of culture, the cell viability of the Ti-6Al-4V was enhanced by depositing with undoped or doped hydroxyapatite. The Ti additions led to an increase in cell viability of hydroxyapatite, after 5 days of culture. The electron microscopy showed the presence of more cells on the surface of Ti-enriched hydroxyapatite than those observed on the surface of the uncoated alloys or undoped hydroxyapatite.


Subject(s)
Biocompatible Materials/chemistry , Durapatite/chemistry , Materials Testing , Titanium/chemistry , Alloys , Cell Line, Tumor , Elastic Modulus , Hardness , Humans , Surface Properties , Tissue Engineering
3.
J Mech Behav Biomed Mater ; 10: 197-205, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22520431

ABSTRACT

Multi-principal-element (TiZrNbHfTa)N and (TiZrNbHfTa)C coatings were deposited on Ti6Al4V alloy by co-sputtering of Ti, Zr, Nb, Hf and Ta metallic targets in reactive atmosphere. The coatings were analyzed for elemental and phase compositions, crystalline structure, morphology, residual stress, hardness, friction performance, wear-corrosion resistance and cell viability. For all the films, only simple fcc solid solutions with (111) preferred orientations were found, with crystallite sizes in the range 7.2-13.5 nm. The coatings were subjected to compressive stress, with values ranging from 0.8 to 1.6 GPa. The carbide coating with the highest carbon content (carbon/metal ≈1.3) exhibited the highest hardness of about 31 GPa, the best friction behavior (µ = 0.12) and the highest wear resistance (wear rate K=0.2×10(-6)mm(3)N(-1)m(-1)), when testing in simulated body fluids (SBFs). Cell viability tests proved that the osteoblast cells were adherent to the coated substrates, and a very high percentage of live cells were observed on sample surfaces, after 72 h incubation time.


Subject(s)
Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Alloys/metabolism , Alloys/toxicity , Biomimetic Materials/metabolism , Body Fluids/metabolism , Cell Line, Tumor , Cell Survival/drug effects , Coated Materials, Biocompatible/metabolism , Coated Materials, Biocompatible/toxicity , Corrosion , Hafnium/chemistry , Humans , Mechanical Phenomena , Niobium/chemistry , Surface Properties , Tantalum/chemistry , Titanium/chemistry , Zirconium/chemistry
4.
J Nanosci Nanotechnol ; 8(2): 717-21, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18464396

ABSTRACT

In the last decade, considerable research effort was directed to the deposition of multilayer films with layer thicknesses in the nanometer range (superlattice coatings), in order to increase the performance of various cutting tools and machine parts. The goal of the present work was to investigate the main microstructural, mechanical and wear resistance characteristics of a superlattice coating, consisting of alternate multilayer ZrN/TiAIN films, with various bilayer periods (5 / 20 nm). The coatings were deposited by the cathodic arc method on Si, plain carbon steel and high speed steel substrates to be used as wear resistance surfaces. The multilayer structures were prepared by using shutters placed in front of each cathode (Zr and Ti+Al). The characteristics of multilayer structures (elemental and phase composition, texture, Vickers microhardness, thickness, adhesion, and wear resistance) were determined by using various techniques (AES, XPS, XRD, microhardness measurements, scratch, and tribological tests). A comparison with the properties of ZrN and TiAIN single-layer coatings was carried out.

5.
J Nanosci Nanotechnol ; 8(2): 733-8, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18464399

ABSTRACT

In recent years, the smart materials have attracted much attention due to their unusual properties such as shape memory effect and pseudoelasticity, being widely used for biomedical implants. These materials contain certain amounts of nickel, titanium and others which are not adequate for surgical implants and prosthesis. In the work reported here, two types of nonostructured multilayer coatings (TiN/ZrN, ZrN/Zr) used to prevent the ions release from shape memory alloys were investigated. For comparison, the TiN and ZrN monolayers were also examined. The films were deposited onto nickel-titanium based alloy (Ti-Ni-Nb) and Ni substrates by vacuum arc deposition technique under various deposition conditions. The concentrations of dissolved ions in Ringer solution for uncoated and coated Ni samples were determined to examine the benefic barrier effect of these coatings for ions release from shape memory alloys. In order to have a more complete characterization of the investigated coatings, other properties such as elemental and phase composition, morphology, texture, microhardness, and adhesion were studied. For all coatings, the concentrations of dissolved ions were lower that those measured in the case of the uncoated specimens. The nanostructured multilayer films exhibited the best mechanical and anticorrosive properties.


Subject(s)
Alloys/chemistry , Biomedical Research/methods , Coated Materials, Biocompatible/chemistry , Nanostructures/chemistry , Biomedical Research/instrumentation , Materials Testing , Nickel/chemistry , Niobium/chemistry , Surface Properties , Titanium/chemistry , Zirconium/chemistry
6.
Article in Romanian | MEDLINE | ID: mdl-752839

ABSTRACT

The study includes 390 patients of different age, operated for various conditions during the last quarter of 1975, and systematically treated post operatively with heparin (the cases in which heparin was contraindicated were not included). None of the patients developed signs of thromboembolism after the operation. The drawbacks of the method are virtually inexistent as compared to the gravity of postoperative thrombolic complications. A further study included 1708 operated patients of whom 223 (13.0%) received the heparin treatment and 1485 (87.0%) did not. There was no thrombolic-embolic complication in the former lot and 12 cases (0.8%) in the latter. Three of 15 patients (20%) in whom the postoperative heparin treatment was interrupted immediately or very soon, developed thromboembolism. The method is efficient provided it is applied after the operation up to complete mobilization of the patient. The method is readily applicable, there is no risk and haemostasis is insured.


Subject(s)
Heparin/therapeutic use , Postoperative Complications/prevention & control , Thromboembolism/prevention & control , Adolescent , Adult , Female , Heparin/administration & dosage , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...