Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 16(5)2023 Feb 28.
Article in English | MEDLINE | ID: mdl-36903117

ABSTRACT

The goal of this stydy was to explore the potential of the enhanced corrosion resistance of Ti(N,O) cathodic arc evaporation-coated 304L stainless steel using oxide nano-layers deposited by atomic layer deposition (ALD). In this study, we deposited Al2O3, ZrO2, and HfO2 nanolayers of two different thicknesses by ALD onto Ti(N,O)-coated 304L stainless steel surfaces. XRD, EDS, SEM, surface profilometry, and voltammetry investigations of the anticorrosion properties of the coated samples are reported. The amorphous oxide nanolayers homogeneously deposited on the sample surfaces exhibited lower roughness after corrosion attack compared to the Ti(N,O)-coated stainless steel. The best corrosion resistance was obtained for the thickest oxide layers. All samples coated with thicker oxide nanolayers augmented the corrosion resistance of the Ti(N,O)-coated stainless steel in a saline, acidic, and oxidising environment (0.9% NaCl + 6% H2O2, pH = 4), which is of interest for building corrosion-resistant housings for advanced oxidation systems such as cavitation and plasma-related electrochemical dielectric barrier discharge for breaking down persistent organic pollutants in water.

2.
Biomed Mater ; 13(2): 025011, 2018 01 30.
Article in English | MEDLINE | ID: mdl-29381477

ABSTRACT

Hydroxyapatite (HAP) coatings are applied on metallic implant materials to combine mechanical properties of metallic material with bioactivity abilities of HAP ceramic. In this study, HAP coatings with additions of Si and Mg are proposed to be deposited on Ti6Al4V substrates by RF magnetron sputtering. Chemical bonding, morphology, topography and corrosion resistance in simulated body fluids (SBF) of the coatings were investigated. Additionally, mechanical and biological properties of the coatings were evaluated. It was found that the addition of Si and Mg does not influence the formation of a HAP phase. All the coatings exhibited smooth surface and uniform growth, without defects or cracks. Both hardness and elastic modulus of the coated samples decrease with Mg addition in the HAP-Si structure. Both Mg and Si addition into HAP coatings were found to enhance the corrosion resistance of the Ti6Al4V alloy in the SBF solution. Coatings with low Mg content exhibited better corrosion performance. All the coatings investigated were biocompatible, as demonstrated by SaOS-2 bone cell attachment and growth. However, cell proliferation and morphology were inferior on samples with the highest Mg content.


Subject(s)
Coated Materials, Biocompatible/chemistry , Durapatite/chemistry , Magnesium/chemistry , Silicon/chemistry , Alloys , Body Fluids/metabolism , Bone and Bones , Cell Adhesion , Cell Line, Tumor , Cell Proliferation , Corrosion , Elasticity , Electrochemical Techniques , Hardness , Humans , Materials Testing , Microscopy, Fluorescence , Osteoblasts/cytology , Osteoblasts/drug effects , Stress, Mechanical , Surface Properties , Titanium/chemistry , X-Ray Diffraction
3.
Proc Inst Mech Eng H ; 229(4): 307-18, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25934259

ABSTRACT

Bioactive coatings are frequently used to improve the osseointegration of the metallic implants used in dentistry or orthopaedics. Among different types of bioactive coatings, hydroxyapatite (Ca10(PO4)6(OH)2) is one of the most extensively used due to its chemical similarities to the components of bones and teeth. In this article, production and characterization of hydroxyapatite films deposited on Ti6Al4V alloy prepared by magnetron sputtering were reported. Besides, SiC was deposited on substrate surface to study the interlayer effect. Obtained coatings were annealed at 600 °C for 30 and 120 min in a mixed atmosphere of N2 + H2O vapours with the heating rate of 12 °C min(-1). The effects of SiC interlayer and heat treatment parameters on the structural, mechanical and corrosion properties were investigated. After heat treatment process, the crystalline hydroxyapatite was obtained. Additionally, cell viability tests were performed. The results show that the presence of the SiC interlayer contributes a decrease in surface roughness and improves the mechanical properties and corrosion performance of the hydroxyapatite coatings. Biological properties were not affected by the presence of the SiC interlayer.


Subject(s)
Biocompatible Materials/chemistry , Carbon Compounds, Inorganic/chemistry , Durapatite/chemistry , Silicon Compounds/chemistry , Titanium/chemistry , Alloys , Biocompatible Materials/toxicity , Carbon Compounds, Inorganic/toxicity , Cell Line, Tumor , Cell Survival/drug effects , Durapatite/toxicity , Humans , Silicon Compounds/toxicity , Surface Properties , Titanium/toxicity
SELECTION OF CITATIONS
SEARCH DETAIL
...