Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 117
Filter
1.
Heart Rhythm O2 ; 5(5): 281-288, 2024 May.
Article in English | MEDLINE | ID: mdl-38840765

ABSTRACT

Background: Interventional cardiac resynchronization therapy (I-CRT) for left ventricular lead (LVL) placement works as a supplement to traditional (over-the-wire) cardiac resynchronization therapy (T-CRT). It has been argued that I-CRT is a time-consuming and complicated procedure. Objective: The purpose of this study was to investigate differences in procedure-related, perioperative, postoperative, and clinical endpoints between I-CRT and T-CRT. Methods: This single-center, retrospective, cohort study included all consecutive patients receiving a CRT-pacemaker/defibrillator between January 1, 2012, and August 31, 2018. Patients underwent T-CRT from January 1, 2012, to June 1, 2015, and I-CRT from January 1, 2016, to August 31, 2018. We obtained data from patient record files, fluoroscopic images, and the Danish Pacemaker and ICD Register. Data were analyzed using Wilcoxon rank-sum/linear regression for continuous variables and the Pearson χ2/Fisher exact for categorical variables. Results: Optimal LVL placement was achieved in 82.7% of the I-CRT group and 76.8% of the T-CRT group (P = .015). In the I-CRT group, 99.0% of LVLs were quadripolar vs 55.3% in the T-CRT group (P <.001). Two or more leads were used during the procedure in 0.7% and 10.5% of all cases in the I-CRT and T-CRT groups, respectively (P <.001). Total implantation time was 81.0 minutes in the I-CRT group and 83.0 minutes in the T-CRT group (P = .41). Time with catheters in the coronary sinus was 45.0 minutes for the I-CRT group vs 37.0 minutes in the T-CRT group, respectively (P <.001). Conclusion: I-CRT did not prolong total implantation time despite longer time with catheters in the coronary sinus. I-CRT allowed more optimal LVL placement, wider use of quadripolar leads, and use of fewer leads during the procedure.

2.
J Clin Med ; 13(9)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38731083

ABSTRACT

Background: Long-term rhythm monitoring (LTRM) can detect undiagnosed atrial fibrillation (AF) in patients at risk of AF and stroke. Circulating microRNAs (miRNAs), which have been shown to play a role in atrial electrical and structural remodelling, could help to select patients who would benefit most from LTRM. The aim of this study was to investigate whether patients with diabetes mellitus (DM) and hypertension and screen-detected subclinical AF (SCAF) using an insertable cardiac monitor (ICM) have significantly different plasma baseline levels of five selected miRNAs playing a role in the modulation of atrial electrical and structural remodelling (miR-21-5p, miR-29b-3p, miR-150-5p, miR-328-3p, and miR-432-5p) compared to those without SCAF. Methods: This study was performed at the outpatient clinic of a secondary academic teaching hospital between December 2013 and November 2015. Eligible patients were ≥65 years of age with DM and hypertension but without known heart diseases. All patients received an ICM. On the day of ICM implantation, blood samples for the measurement of plasma levels of the five miRNAs were drawn. In this post hoc analysis, we investigated their expression by reverse transcription-quantitative polymerase chain reaction. MiRNA plasma levels in patients with and without newly detected SCAF were compared. Results: We included 82 consecutive patients (median age of 71.3 years (IQR 67.4-75.1)), who were followed for a median of 588 days (IQR: 453-712 days). Seventeen patients (20.7%) had ICM-detected SCAF. Plasma levels of miR-328-3p, miR-29b-3p, miR-21-5p, miR-432-5p, and miR-150-5p were slightly but not significantly different in patients with incident SCAF compared with patients without. Conclusions: In patients with hypertension and DM, newly detected SCAF was not significantly associated with changes in expression levels of miR-21-5p, miR-29b-3p, miR-150-5p, miR-328-3p, and miR-432-5p.

5.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38533841

ABSTRACT

Contemporary management of atrial fibrillation (AF) has become increasingly complex. Therefore, strong efforts have been made during the past decade to develop models for structured, integrated care for patients with AF. These have also been incorporated in international guidelines for the management of patients with AF. However, implementation of integrated care approaches in daily clinical practice is scarce and far from optimal, and it may require a re-thinking of the structure of the healthcare system. The reasons for the poor implementation are many, from limited time and economic resources to deficits in postgraduate education of healthcare professionals, lack of involvement of patients in how integrated care should be designed, and fragmentation of the healthcare system. Moreover, patients' psychological challenges, which not only impact patients' adherence to treatment but, if untreated, increase their risk of morbidity, mortality, and poor quality of life, are not given sufficient attention. It is time to start a necessary discussion of what integrated care should be, what it should contain, and what is necessary to implement it in daily clinical practice.


Subject(s)
Atrial Fibrillation , Delivery of Health Care, Integrated , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Quality of Life
6.
Circ Cardiovasc Imaging ; 17(3): e016197, 2024 03.
Article in English | MEDLINE | ID: mdl-38440875

ABSTRACT

BACKGROUND: Left atrial (LA) speckle tracking provides detailed information on atrial function. Its utility for predicting subclinical atrial fibrillation (SCAF) is unclear. Therefore, we sought to investigate whether LA strain measures could predict SCAF detected by long-term continuous rhythm monitoring. METHODS: This was an echocardiographic substudy of the LOOP study, where elderly at risk of stroke were randomized to receive a loop recorder (Reveal LINQ) or control. Participants who received a loop recorder were included in this analysis. Echocardiography included LA reservoir, conduit, and contraction strain. Participants were followed with continuous rhythm monitoring for SCAF (≥6 minutes). Cox proportional hazards regression was applied to adjust for atrial fibrillation risk factors. RESULTS: In total, 956 participants were eligible for analysis. Median continuous rhythm monitoring was 35 months (IQR, 20-40 months), during which 278 (29%) were diagnosed with SCAF. The mean age was 74 years, 56% were male, median CHA2DS2-VASc-score was 4. LA reservoir strain was an independent predictor of SCAF after multivariable adjustments (HR, 1.04 [1.02-1.05], per 1% decrease) and so was contraction strain. The findings were unchanged in competing risk analyses and in participants with normal LA size and diastolic function. Participants with low reservoir strain (<33%) had a significantly higher risk of SCAF compared with those with high reservoir strain (incidence rate, 14.5 [12.4-16.9] versus 9.8 [8.2-11.8] events/100 person-years). The same was noted for low versus high contraction strain. CONCLUSIONS: LA reservoir and contraction strain are independent predictors of SCAF in elderly at risk of stroke. This also applies to individuals with normal LA size and diastolic function. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02036450.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Male , Aged , Female , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/complications , Heart Atria/diagnostic imaging , Echocardiography , Stroke/etiology , Stroke/diagnosis
7.
J Am Heart Assoc ; 13(4): e032744, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38353260

ABSTRACT

BACKGROUND: The ABC-stroke score is a risk scheme for prediction of stroke or systemic embolism (SE) in atrial fibrillation (AF). This study sought to examine whether the score could be useful in predicting stroke in AF-naïve individuals and risk stratifying for AF screening. METHODS AND RESULTS: The LOOP (Atrial Fibrillation Detected by Continuous ECG Monitoring Using Implantable Loop Recorder to Prevent Stroke in High-Risk Individuals) study randomized 6004 AF-naïve individuals aged 70 to 90 years with stroke risk factors to either screening with an implantable loop recorder and anticoagulation upon detection of new-onset AF episodes ≥6 minutes, or usual care. A total of 5781 participants had available ABC-stroke score at baseline and were included in this secondary analysis: 4170 (72.1%) with an estimated stroke/SE risk ≤1%/year versus 1611 (27.9%) with an estimated stroke/SE risk >1%/year. Having an annual ABC-stroke risk >1% was associated with stroke/SE, stroke/SE/cardiovascular death, and all-cause death (hazard ratio, 1.82 [95% CI, 1.44-2.21], 2.17 [95% CI, 1.80-2.62], and 2.19 [95% CI, 1.87-2.56], respectively). For screening with implantable loop recorder versus usual care, no significant reduction in these study outcomes was obtained in any ABC-stroke risk groups (P>0.0500 for all), with no signal toward interaction (Pinteraction>0.2500 for all). Similar findings were yielded when assessing the ABC-stroke score as a continuous variable. CONCLUSIONS: In an elderly, AF-naïve population with additional stroke risk factors, a higher ABC-stroke score could identify individuals with increased stroke risk. However, this risk score may not be useful in pinpointing those more likely to benefit from AF screening and subsequent preventive treatment. These findings should be considered as hypothesis generating and warrant further study. REGISTRATION: URL: https://www.clinicaltrials.gov; unique identifier: NCT02036450.


Subject(s)
Atrial Fibrillation , Stroke , Aged , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Risk Factors , Stroke/etiology , Stroke/prevention & control , Stroke/diagnosis , Aged, 80 and over
9.
Int J Cardiovasc Imaging ; 40(3): 591-599, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38245893

ABSTRACT

Epicardial adipose tissue (EAT) has endocrine and paracrine functions and has been associated with metabolic and cardiovascular disease. This study aimed to investigate the association between EAT, determined by cardiac magnetic resonance imaging (CMR), and incident atrial fibrillation (AF) following long-term continuous heart rhythm monitoring by implantable loop recorder (ILR). This study is a sub-study of the LOOP study. In total, 203 participants without a history of AF received an ILR and underwent advanced CMR. All participants were at least 70 years of age at inclusion and had at least one of the following conditions: hypertension, diabetes, previous stroke, or heart failure. Volumetric measurements of atrial- and ventricular EAT were derived from CMR and the time to incident AF was subsequently determined. A total of 78 participants (38%) were diagnosed with subclinical AF during a median of 40 (37-42) months of continuous monitoring. In multivariable Cox regression analyses adjusted for age, sex, and various comorbidities, we found EAT indexed to body surface area to be independently associated with the time to AF with hazard ratios (95% confidence intervals) up to 2.93 (1.36-6.34); p = 0.01 when analyzing the risk of new-onset AF episodes lasting ≥ 24 h. Atrial EAT assessed by volumetric measurements on CMR images was significantly associated with the incident AF episodes as detected by ILR.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/complications , Epicardial Adipose Tissue , Predictive Value of Tests , Magnetic Resonance Imaging , Heart Atria , Adipose Tissue/diagnostic imaging
10.
TH Open ; 8(1): e19-e30, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38197016

ABSTRACT

Background Atrial fibrillation (AF) prevalence is rising; however, data on the bleeding risks associated with the detection of subclinical AF are needed. Objective Our objective was to determine the bleeding increment associated with implantable loop recorder (ILR) screening for subclinical AF and subsequent anticoagulation initiation compared with usual care. Methods This post hoc study utilized LOOP trial data from 6,004 elderly patients with stroke risks randomized to either ILR ( n = 1,503) or usual care ( n = 4,503). The mean follow-up time was 64.5 months, and none were lost to follow-up. The primary exposure was the initiation of oral anticoagulation, and the main outcome was the risk of major bleeding events following initiation of oral anticoagulants (OACs), determined by time-dependent cox regression. Second, we investigated antithrombotic prescription patterns and major bleeding events after antiplatelet treatment and in subgroups. Results OAC was initiated in 1,019 participants with a mean age (years) of 78.8 (± 4.67) in control versus 77.0 (± 4.84) in ILR, p < 0.0001. Altogether did 202 participants end or pause OAC treatment. Among AF patients (n = 910) had 40 (28%) completely ended OAC and 105 (72%) temporarily paused OAC during follow-up. Major bleeding events totaled 221 (3.7%). Forty-seven major bleeding events followed an OAC initiation in 1,019 participants (4.6%); 26 versus 21 events in the control and ILR groups, respectively. The hazard ratio (HR) for major bleeding after OAC initiation compared with before initiation was 2.08 (1.50-2.90) p < 0.0001 overall, 2.81 (1.82-4.34) p < 0.0001 for control and 1.32 (0.78-2.23) p = 0.31 for the ILR group ( p = 0.07 for interaction). Antiplatelet treatment resulted in an overall adjusted HR of 1.3 (0.96-1.75) p = 0.09. For OAC users aged ≥75 years in the ILR group, the rate of major bleeding was 1.73 (0.92-2.96) compared with 0.84 (0.36-1.66) for an age <75 years, and the rate of the corresponding control subgroup aged ≥75 years was 2.20 (1.23-3.63) compared with 1.64 (0.82-2.93) for an age <75 years. Conclusion The individual risk of major bleeding increased twofold after initiation of oral anticoagulation for all patients in this study. However, the patients screened for subclinical AF did not have a higher bleeding risk after initiation of anticoagulation compared with those in usual care. Trial Registration: The LOOP study is registered at ClinicalTrials.gov, identifier: NCT020364 50.

11.
Eur Heart J ; 45(10): 837-849, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-37956458

ABSTRACT

BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24 h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24 h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.


Subject(s)
Atrial Fibrillation , Pyridines , Stroke , Thiazoles , Humans , Female , Aged , Aged, 80 and over , Male , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Atrial Fibrillation/diagnosis , Heart Atria , Risk Factors , Stroke/etiology , Stroke/prevention & control , Stroke/diagnosis , Anticoagulants/therapeutic use
13.
Clin Epidemiol ; 15: 1259-1272, 2023.
Article in English | MEDLINE | ID: mdl-38149081

ABSTRACT

Aim: The Danish Atrial Fibrillation (AF) Registry monitors and supports improvement of quality of care for all AF patients in Denmark. This report describes the registry's administrative and organizational structure, data sources, data flow, data analyses, annual reporting, and feedback between the registry, clinicians, and the administrative system. We also report the selection process of the quality indicators and the temporal trends in results from 2017-2021. Methods and Results: The Danish AF Registry aims for complete registration and monitoring of care for all patients diagnosed with AF in Denmark. Administrative registries provide data on contacts to general practice, contacts to private cardiology practice, hospital contacts, medication prescriptions, updated vital status information, and biochemical test results. The Danish Stroke Registry provides information on stroke events. From 2017 to 2021, the proportion with a reported echocardiography among incident AF patients increased from 39.9% (95% CI: 39.3-40.6) to 82.6% (95% CI: 82.1-83.1). The initiation of oral anticoagulant therapy among patients with incident AF and a CHA2DS2-VASc score of ≥1 in men and ≥2 in women increased from 85.3% (95% CI: 84.6-85.9) to 90.4% (95% CI: 89.9-91.0). The 1-year and 2-year persistence increased from 85.2% (95% CI: 84.5-85.9) to 88.7% (95% CI: 88.0-89.3), and from 85.4% (95% CI: 84.7-86.2) to 88.2% (95% CI: 87.5-88.8), respectively. The 1-year risk of ischemic stroke among prevalent patients with AF decreased from 0.88% (95% CI: 0.83-0.93) to 0.71% (95% CI: 0.66-0.75). Variation in clinical performance between the five administrative Danish regions was reduced. Conclusion: Continuous nationwide monitoring of quality indicators for AF originating from administrative registries is feasible and supportive of improvements of quality of care.

15.
Am J Cardiol ; 205: 457-464, 2023 10 15.
Article in English | MEDLINE | ID: mdl-37666019

ABSTRACT

Morphology-voltage-P-wave-duration (MVP) score combining P-wave duration (PWD), P-wave voltage in lead I (PWVI), and interatrial block (IAB) has been demonstrated to predict atrial fibrillation (AF). Therefore, this study aimed to examine MVP score and its P-wave components as potential predictors of AF screening effects on stroke prevention. This was a secondary analysis of the LOOP Study (Atrial Fibrillation detected by Continuous ECG Monitoring using Implantable Loop Recorder to prevent Stroke in High-risk Individuals) which randomized older persons (aged 70 to 90 years) with additional stroke risk factors to either continuous monitoring with implantable loop recorder and anticoagulation upon detection of AF episodes ≥6 minutes (the intervention group), or usual care. A total of 5,759 participants were included in the present analysis, where PWD, PWVI, and IAB were determined through a computerized analysis of 12-lead electrocardiogram and further employed to calculate baseline MVP score (0 to 6) for each participant. In total, 305 (5.3%) had stroke or systemic embolism during follow-up, with a higher risk in the group with MVP score 5 to 6 than those having score 0 to 2 (hazard ratio (HR) 1.54 [95% confidence interval (CI) 1.01 to 2.35]). This risk increase was mainly upheld by participants with IAB (HR 1.62 [95% CI 1.11 to 2.36] for IAB vs no IAB) and with longer PWD (HR 1.37 [95% CI 1.07 to 1.75] for >110 vs ≤110 ms). Compared with usual care, implantable loop recorder screening did not significantly reduce the risk of stroke or systemic embolism in any MVP risk categories (HR 0.80 [95% CI 0.60 to 1.08] for MVP score 0 to 2, 0.54 [95% CI 0.16 to 1.85] for MVP score 3 to 4, and 0.89 [95% CI 0.35 to 2.25] for MVP score 5 to 6; pinteraction = 0.78). In conclusion, a higher MVP score was associated with an increased stroke risk, but it did not demonstrate an association with effects of AF screening on stroke prevention. These findings should be considered hypothesis-generating and warrant further study.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Aged , Aged, 80 and over , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Electrocardiography , Interatrial Block , Risk Factors , Stroke/epidemiology , Stroke/prevention & control
16.
N Engl J Med ; 389(13): 1167-1179, 2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37622677

ABSTRACT

BACKGROUND: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known. METHODS: We conducted an event-driven, double-blind, double-dummy, randomized trial involving patients 65 years of age or older who had AHREs lasting for at least 6 minutes and who had at least one additional risk factor for stroke. Patients were randomly assigned in a 1:1 ratio to receive edoxaban or placebo. The primary efficacy outcome was a composite of cardiovascular death, stroke, or systemic embolism, evaluated in a time-to-event analysis. The safety outcome was a composite of death from any cause or major bleeding. RESULTS: The analysis population consisted of 2536 patients (1270 in the edoxaban group and 1266 in the placebo group). The mean age was 78 years, 37.4% were women, and the median duration of AHREs was 2.8 hours. The trial was terminated early, at a median follow-up of 21 months, on the basis of safety concerns and the results of an independent, informal assessment of futility for the efficacy of edoxaban; at termination, the planned enrollment had been completed. A primary efficacy outcome event occurred in 83 patients (3.2% per patient-year) in the edoxaban group and in 101 patients (4.0% per patient-year) in the placebo group (hazard ratio, 0.81; 95% confidence interval [CI], 0.60 to 1.08; P = 0.15). The incidence of stroke was approximately 1% per patient-year in both groups. A safety outcome event occurred in 149 patients (5.9% per patient-year) in the edoxaban group and in 114 patients (4.5% per patient-year) in the placebo group (hazard ratio, 1.31; 95% CI, 1.02 to 1.67; P = 0.03). ECG-diagnosed atrial fibrillation developed in 462 of 2536 patients (18.2% total, 8.7% per patient-year). CONCLUSIONS: Among patients with AHREs detected by implantable devices, anticoagulation with edoxaban did not significantly reduce the incidence of a composite of cardiovascular death, stroke, or systemic embolism as compared with placebo, but it led to a higher incidence of a composite of death or major bleeding. The incidence of stroke was low in both groups. (Funded by the German Center for Cardiovascular Research and others; NOAH-AFNET 6 ClinicalTrials.gov number, NCT02618577; ISRCTN number, ISRCTN17309850.).


Subject(s)
Anticoagulants , Arrhythmias, Cardiac , Embolism , Factor Xa Inhibitors , Aged , Female , Humans , Male , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Embolism/drug therapy , Embolism/etiology , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Hemorrhage/chemically induced , Stroke/etiology , Stroke/prevention & control , Electrodes, Implanted , Double-Blind Method , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Risk Factors
17.
Europace ; 25(7)2023 07 04.
Article in English | MEDLINE | ID: mdl-37345804

ABSTRACT

Atrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences. The presence of AHRE increases the risk of stroke compared with patients without AHRE. Oral anticoagulation would have the potential to reduce the risk of stroke in patients with AHRE but is also associated with a rate of major bleeding of ∼2%/year. The stroke rate in patients with AHRE appears to be lower than the stroke rate in patients with atrial fibrillation. Wearables like smart-watches will increase the absolute number of patients in whom atrial arrhythmias are detected. It remains unclear whether anticoagulation is effective and, equally important, safe in patients with AHRE. Two randomized clinical trials, NOAH-AFNET6 and ARTESiA, are expected to report soon. They will provide much-needed information on the efficacy and safety of oral anticoagulation in patients with AHRE.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Risk Factors , Anticoagulants/therapeutic use , Heart Atria , Stroke/diagnosis , Stroke/etiology , Stroke/prevention & control
18.
BMJ Open ; 13(5): e069595, 2023 05 10.
Article in English | MEDLINE | ID: mdl-37164465

ABSTRACT

INTRODUCTION: Atrial fibrillation (AF) is the most common postoperative complication after surgical aortic valve replacement (SAVR) and occurs in up to 50% of the patients. Development of postoperative AF (POAF) is associated with a 2-3 fold increased risk of adverse events, including stroke, myocardial infarction and death.Several studies have implied that prophylactic Atorvastatin therapy could prevent POAF in patients undergoing coronary artery bypass graft. These studies suggest that Atorvastatin has rapid and significant pleiotropic actions that reduce the risk of POAF. However, prophylactic treatment with statins has yet to be understood in SAVR. The aim of this study is to investigate whether prophylactic administration of torvastatin reduces POAF in patients undergoing SAVR. METHODS AND ANALYSIS: In this investigator-initiated, prospective, parallel-group, randomised, double-blind, placebo-controlled single-centre trial, 266 patients undergoing elective solitary SAVR with bioprosthetic valve, with no prior history of AF, and statin-naïve will be randomised (1:1) to treatment with Atorvastatin (80 mg once daily) or matching placebo for 1-2 weeks prior to and 30 days after surgery. The primary endpoint is POAF defined as an episode of irregular RR-intervals without a traceable p-wave of at least 30 s duration. After discharge and until day 30 after surgery, POAF will be documented by either rhythm strip or 12-lead ECG. ETHICS AND DISSEMINATION: Protocol approval has been obtained from the Regional Scientific Ethical Committee for Southern Denmark (S-20210159), The Danish Medicines Agency (2021103821) and the Data Protection Agency (21/65621).The trial is conducted in accordance with the Declaration of Helsinki, the ICH-GCP (International Conference on Harmonisation Good Clinical Practice) guidelines and the legal regulations of Denmark. Study findings will be shared via peer-reviewed journal publication and conference presentations. TRIAL REGISTRATION NUMBER: NCT05076019.


Subject(s)
Atrial Fibrillation , Hydroxymethylglutaryl-CoA Reductase Inhibitors , Humans , Adult , Atorvastatin/therapeutic use , Atrial Fibrillation/etiology , Atrial Fibrillation/prevention & control , Aortic Valve/surgery , Prospective Studies , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Denmark , Hospitals , Postoperative Complications/etiology , Randomized Controlled Trials as Topic
19.
Trials ; 24(1): 250, 2023 Apr 01.
Article in English | MEDLINE | ID: mdl-37005636

ABSTRACT

BACKGROUND: A key decision in the treatment of atrial fibrillation is choosing between a rhythm control strategy or a rate control strategy as the main strategy. When choosing rate control, the optimal heart rate target is uncertain. The Danish Atrial Fibrillation trial is a randomized, multicenter, two-group, superiority trial comparing strict rate control versus lenient rate control in patients with either persistent or permanent atrial fibrillation at inclusion. To prevent bias arising from selective reporting and data-driven analyses, we developed a predefined description of the statistical analysis. METHODS: The primary outcome of this trial is the physical component score of the SF-36 questionnaire. A total of 350 participants will be enrolled based on a minimal important difference of 3 points on the physical component score of the SF-36 questionnaire, a standard deviation of 10 points, a statistical power of 80% (beta of 20%), and an acceptable risk of type I error of 5%. All secondary, exploratory, and echocardiographic outcomes will be hypothesis-generating. The analyses of all outcomes will be based on the intention-to-treat principle. We will analyze continuous outcomes using linear regression adjusting for "site," type of atrial fibrillation at inclusion (persistent/ permanent), left ventricular ejection fraction (≥ 40% or < 40%), and the baseline value of the outcome (all as fixed effects). We define our threshold for statistical significance as a p-value of 0.05 and assessments of clinical significance will be based on the anticipated intervention effects defined in the sample size and power estimations. Thresholds for both statistical and clinical significance will be assessed according to the 5-step procedure proposed by Jakobsen and colleagues. DISCUSSION: This statistical analysis plan will be published prior to enrolment completion and before any data are available and is sought to increase the validity of the DANish Atrial Fibrillation trial. TRIAL REGISTRATION: Clinicaltrials.gov NCT04542785. Registered on Sept 09, 2020.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Atrial Fibrillation/complications , Stroke Volume , Ventricular Function, Left , Research Design , Denmark , Treatment Outcome
20.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37068888

ABSTRACT

AIMS: Insights into subclinical atrial fibrillation (AF) development are warranted to inform the strategies of screening and subsequent clinical management upon AF detection. Hence, this study sought to characterize the onset and progression of subclinical AF with respect to 12-lead electrocardiogram (ECG) parameters. METHODS AND RESULTS: We included AF-naïve individuals aged 70-90 years with additional stroke risk factors who underwent implantable loop recorder (ILR) monitoring in the LOOP Study. Using data from daily ILR recordings and the computerized analysis of baseline ECG, we studied empirically selected ECG parameters for AF detection (≥6 min), cumulative AF burden, long-lasting AF (≥24 h), and AF progression. Of 1370 individuals included, 419 (30.6%) developed AF during follow-up, with a mean cumulative AF burden of 1.5% [95% CI: 1.2-1.8]. Several P-wave-related and ventricular ECG parameters were associated with new-onset AF and with cumulative AF burden in AF patients. P-wave duration (PWD), P-wave terminal force in Lead V1, and interatrial block (IAB) further demonstrated significant associations with long-lasting AF. Among AF patients, we observed an overall reduction in cumulative AF burden over time (IRR 0.70 [95% CI: 0.51-0.96]), whereas IAB was related to an increased risk of progression to AF ≥24 h (HR 1.86 [95% CI: 1.02-3.39]). Further spline analysis also revealed longer PWD to be associated with this progression in AF duration. CONCLUSION: We identified several ECG parameters associated with new-onset subclinical AF detected by ILR. Especially PWD and IAB were robustly related to the onset and the burden of AF as well as progression over time.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/complications , Electrocardiography/methods , Stroke/prevention & control , Risk Factors , Electrodes, Implanted/adverse effects , Interatrial Block , Electrocardiography, Ambulatory
SELECTION OF CITATIONS
SEARCH DETAIL
...