1.
J Chromatogr A ; 1067(1-2): 245-54, 2005 Mar 04.
Article in English | MEDLINE | ID: mdl-15844530

ABSTRACT

The principles, practicability and potential of comprehensive two-dimensional (2D) gas chromatography coupled to a rapid-scanning quadrupole mass spectrometer (GC x GC-qMS) for the analysis of complex flavour mixtures in food, allergens in fragrances and polychlorinated biphenyls (PCBs) were studied. With a scan speed of 10,000 amu/s, monitoring over a mass range of up to 200 atomic mass unit (amu) can be achieved at an acquisition frequency of 33 Hz. Extending this mass range and/or increasing the data acquisition frequency results in a loss of spectral quality. Optimal parameter settings allow, next to unambiguous identification/confirmation of target compounds on the basis of high-quality mass spectra, fully satisfactory quantification (three to four modulations per peak) with linear calibration plots and detection limits in the low-pg level. The potential of time-scheduled data acquisition to increase the effective mass range within one GC x GC run was also explored. The analyses, with baseline separation of the flavours, allergens and PCB target compounds, took less than 30 min.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Allergens/analysis , Flavoring Agents/analysis , Gas Chromatography-Mass Spectrometry/instrumentation , Olive Oil , Plant Oils/chemistry , Polychlorinated Biphenyls/analysis , Sensitivity and Specificity
2.
J Chromatogr A ; 1019(1-2): 65-77, 2003 Nov 26.
Article in English | MEDLINE | ID: mdl-14650605

ABSTRACT

Different cryogenic and a heated GC x GC modulator(s) were evaluated and compared for the analysis of high-boiling halogenated compounds. The cryogenic modulators investigated were: (i) the longitudinally modulated cryogenic system; (ii) the liquid-nitrogen-cooled jet modulator (KT2001); (iii) a dual-jet CO2 modulator (made in-house); (iv) a semi-rotating cryogenic modulator (made in-house) and (v) a CO2 loop modulator (KT2003); the heated modulator was the slotted heater system (sweeper). Each modulator was optimised with respect to analyte peak widths at half height in the second-dimension. n-Alkanes, chlorinated alkanes, polychlorinated biphenyls (PCBs) and fluorinated polycyclic aromatic hydrocarbons (F-PAHs) were used as test analytes. The flow rate of the coolant was found to be an important parameter, i.e. the flow rate of the gaseous nitrogen in the KT2001, and of the liquid CO2 in the other cryogenic modulators. For the slotted heater the stroke velocity and pause time were important parameters. This modulator had a limited application range in terms of temperature due to a necessary 100 degrees C difference between sweeper and oven temperature. All cryogenic modulators were found to be suitable for the GC x GC analysis of high-boiling compounds, but the CO2 modulators are to be preferred to the KT2001 due to a wider application range and slightly narrower peaks. As regards the performance of three commercially available electron-capture detectors (ECDs), the aim was to obtain narrow peak widths in GC x GC, i.e. to avoid band broadening caused by the cell volume. The most important parameters were the flow rate of the make-up gas and the detector temperature which both should be as high as possible. Comparison of analyte peak widths obtained with ECD mode and flame ionisation detection (FID) showed that all ECDs exhibited band broadening compared to the FID. The narrowest peaks were obtained with the Agilent micro-ECD, which has a cell volume of only 150 microl.


Subject(s)
Chromatography, Gas/methods , Organic Chemicals/analysis