2.
Clin Biochem ; 32(2): 109-12, 1999 Mar.
Article in English | MEDLINE | ID: mdl-10211626

ABSTRACT

OBJECTIVES: Evaluation of the analytical performance of a biosensor for the measurement of lactate in whole blood samples and comparison of the results of patients samples with a routinely used spectrophotometric enzymatic method. DESIGN AND METHODS: Heparinized whole blood samples of patients and aqueous control samples were used to determine precision and carry-over. For comparison of the lactate biosensor and the enzymatic method human blood samples were split and measured. RESULTS: Satisfactory within-run (n = 7) and day-to-day (n = 15) precision was found, while carry-over was minimal (<0.2%). A statistically significant relation between the lactate levels in whole blood samples (n = 31) and the corresponding plasma samples was found: y = 0.98x - 0.05 and r = 1.00. No correlation was found between the hematocrit (range 0.23-0.51) and the difference in lactate concentration between plasma and whole blood. When comparing patient results (n = 722) obtained with the spectrophotometric method and the biosensor method, the biosensor measured 13% higher lactate levels. A correction on the basis of the hematocrit minimized this difference. CONCLUSION: The combination of analytical performance, easy handling, rapid analysis, and measurement in whole blood makes the biosensor suitable for lactate STAT-analyses. Care must be given to the interpretation of the results as well as to the preanalytical aspects.


Subject(s)
Biosensing Techniques , Lactic Acid/blood , Evaluation Studies as Topic , Humans , Spectrophotometry/methods
3.
Eur J Clin Chem Clin Biochem ; 35(11): 853-4, 1997 Nov.
Article in English | MEDLINE | ID: mdl-9426343

ABSTRACT

Newborns and children may suffer from extremely high ammonia levels in their blood. We evaluated a fast, reliable micromethod, based on the Blood Ammonia Checker II (BAC II) in combination with the dilution with fresh whole blood. Comparison of the proposed method with an enzymatic method revealed a statistically significant correlation. We conclude that the dilution of patient's blood with fresh whole blood extends the measuring range of ammonia on the BAC II analyzer from 286 mumol/l to about 700 mumol/l.


Subject(s)
Ammonia/blood , Blood Chemical Analysis/methods , Child , Humans , Infant, Newborn , Microchemistry/methods , Reagent Kits, Diagnostic , Reproducibility of Results