Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Diagn Microbiol Infect Dis ; 97(2): 115033, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32317130

ABSTRACT

Despite improvement in vaccinations, Hepatitis B remains a major health concern due to the difficulty of prevention even in low endemic areas such as Europe. In this report we describe the performance characteristics of the new HBsAg Next Qualitative and HBsAg Next Confirmatory assays designed for blood screening and diagnostic purposes on the Alinity i and ARCHITECT fully automated systems. The new assays were evaluated in comparison to the ARCHITECT HBsAg Qualitative II and Confirmatory assays on seroconversion, analytical sensitivity, and mutant panels along with testing of over 400 clinical positive samples demonstrating excellent improvements in sensitivity. Additionally, specificity was shown to be improved with testing of over 6000 donors and 240 diagnostic specimens. Overall, the Alinity i & ARCHITECT HBsAg Next assays have taken a step forward in improving the detection of Hepatitis B virus.


Subject(s)
Hepatitis B Surface Antigens/blood , Hepatitis B/diagnosis , Immunoassay/methods , Automation, Laboratory , Clinical Laboratory Techniques/methods , DNA, Viral/blood , Hepatitis B/blood , Hepatitis B virus , Humans , Mass Screening , Mutation , Reagent Kits, Diagnostic , Sensitivity and Specificity , Seroconversion
2.
Diagn Microbiol Infect Dis ; 79(3): 310-6, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24809858

ABSTRACT

In the current evaluation, Epstein-Barr virus (EBV) serology was performed on 1113 routine serum samples. Although the initial request for all samples from the general practitioner was EBV IgM testing, 80.9% were classified as past infections. The ARCHITECT(®) viral capsid antigen (VCA) IgM, VCA IgG, and EBV nuclear antigen (EBNA) 1 IgG assays showed good results for sensitivity and specificity, being 100.0%, 98.3%, and 100.0% and 99.9%, 95.4%, and 99.6%, respectively. Using an algorithm based on initial EBNA-1 IgG testing, followed by VCA IgG and IgM for samples that were not EBNA-1 IgG reactive, the number of tests per sample could be reduced to nearly 50% compared to parallel testing. The high sensitivity and specificity of the ARCHITECT(®) EBNA-1 IgG assay in combination with a low number of grayzone results are a precondition for the chosen test algorithm. Thus, the newly developed ARCHITECT(®) EBV panel is suitable for accurate and cost-efficient EBV serology in a routine clinical laboratory.


Subject(s)
Antibodies, Viral/blood , Diagnostic Tests, Routine/methods , Epstein-Barr Virus Infections/diagnosis , Herpesvirus 4, Human/isolation & purification , Algorithms , Antigens, Viral , Herpesvirus 4, Human/immunology , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Sensitivity and Specificity , Serologic Tests/methods
3.
Diagn Microbiol Infect Dis ; 65(3): 279-87, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19822270

ABSTRACT

We assessed the performance of the ARCHITECT Toxo IgG, IgM, and IgG Avidity assays against corresponding assays on AxSYM and Vidas using 730 sera from pregnant women. The ARCHITECT Toxo IgG and IgM assays showed a relative sensitivity of 97.5% and 89.9% and a relative specificity of 99.1% and 99.8%, respectively. If IgM sensitivity is calculated only for sera drawn less than 4 months after infection, the relative sensitivity rises to 98.1%. Correlation between the ARCHITECT and Vidas Avidity assays was 0.87 (n = 103). Testing 86 IgG-positive specimens from recent infection (<4 months), we never obtained high avidity results, but 2 specimens were in the gray zone, whereas sera from past infections (>4 months) exhibited high avidity results in 72.5% (137/189) of cases. The method can be used reliably to exclude recent infections in sera with concurrently positive results for IgM and IgG (IgG, >3 IU/mL).


Subject(s)
Antibodies, Protozoan/immunology , Immunoassay/methods , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Pregnancy Complications, Parasitic/diagnosis , Toxoplasma/isolation & purification , Toxoplasmosis/diagnosis , Antibodies, Protozoan/blood , Antibody Affinity , Automation, Laboratory/methods , Diagnosis, Differential , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Pregnancy , Pregnancy Complications, Parasitic/blood , Pregnancy Complications, Parasitic/immunology , Pregnancy Complications, Parasitic/parasitology , Reference Values , Sensitivity and Specificity , Toxoplasma/immunology , Toxoplasmosis/immunology
4.
Diagn Microbiol Infect Dis ; 64(3): 275-82, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19464840

ABSTRACT

Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays.


Subject(s)
Immunoglobulin M/blood , Reagent Kits, Diagnostic , Toxoplasma/immunology , Toxoplasmosis/diagnosis , Animals , Female , Humans , Immunoassay/methods , Pregnancy , Sensitivity and Specificity
5.
J Clin Microbiol ; 47(3): 603-13, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19129411

ABSTRACT

Determination of the avidity of immunoglobulin G (IgG) directed against a specific marker has become an established diagnostic tool for identifying or excluding acute infections with pathogens. A novel assay format termed AVIcomp (avidity competition based on mass action) circumventing the conventional chaotropic format has been developed for determination of the avidity of marker-specific IgG in patient specimens. Its applications for cytomegalovirus (CMV) and Toxoplasma gondii are presented. Specific high-avidity IgG from the patient specimen is selectively blocked using a soluble antigen in a sample pretreatment reagent, and the amount of remaining specific low-avidity IgG is determined relative to that in an untreated control. The comparison of the conventional chaotropic format, represented by the Radim CMV IgG Avidity assay, and the newly developed AVIcomp method, as exemplified by the Architect CMV IgG Avidity assay, on blood drawn within 4 months after seroconversion revealed a sensitivity of 100% (97.3% by an alternative calculation) for the AVIcomp format versus 87.5% (75.7% by an alternative calculation) for the chaotropic avidity assay. The specificity on 312 CMV IgG reactive and CMV IgM nonreactive specimens from pregnant women was 100% for the AVIcomp assay and 99.7% for the conventional avidity assay. The Architect Toxo IgG Avidity assay showed an agreement of 97.2% with the bioMérieux Vidas Toxo IgG Avidity Assay employing chaotropic reagents. These performance data suggest that the AVIcomp format shows superior sensitivity and equivalent specificity for the determination of IgG avidity to assays based on the chaotropic method and that the AVIcomp format may also be applicable to other disease states.


Subject(s)
Antibodies, Protozoan/immunology , Antibodies, Viral/immunology , Antibody Affinity , Cytomegalovirus Infections/diagnosis , Immunoglobulin G/immunology , Toxoplasmosis/diagnosis , Animals , Automation , Cytomegalovirus/immunology , Cytomegalovirus Infections/immunology , Humans , Immunoglobulin M/immunology , Sensitivity and Specificity , Toxoplasma/immunology , Toxoplasmosis/immunology
6.
Diagn Microbiol Infect Dis ; 62(3): 235-44, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18715735

ABSTRACT

The ARCHITECT Toxo IgG and IgG Avidity assays have been developed as a fully automated panel for immune status determination and acute infection exclusion. Resolved relative specificity and sensitivity of the ARCHITECT Toxo IgG assay were 99.6% (1359/1365) and 99.7% (1096/1099) as determined on pregnant females, blood donor, and diagnostic specimens. Seroconversion sensitivity of the ARCHITECT assay was comparable with the AxSYM Toxo IgG assay. The ARCHITECT Toxo IgG Avidity assay detected 100.0% (124/124) of acute phase specimens (<4 months after infection) as low avidity, whereas the Vidas Toxo IgG Avidity assay detected 98.9% (89/90) as low avidity. In summary, the ARCHITECT Toxo IgG assay, using recombinant antigens, showed excellent specificity and sensitivity for acute phase as well as past infection specimens. The ARCHITECT Toxoplasmosis panel can be reliably used to rule out acute Toxoplasma gondii infection in pregnant women.


Subject(s)
Antibodies, Protozoan/immunology , Antibody Affinity , Immunoglobulin G/immunology , Serologic Tests/methods , Toxoplasma/immunology , Toxoplasmosis/diagnosis , Acute Disease , Animals , Antibodies, Protozoan/blood , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Immunoglobulin M/immunology , Pregnancy , Pregnancy Complications, Parasitic/diagnosis , Pregnancy Complications, Parasitic/parasitology , Recombinant Proteins , Reproducibility of Results , Sensitivity and Specificity , Toxoplasma/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL
...