1.
Rev. Soc. Esp. Enferm. Nefrol ; 11(4): 265-270, oct.-dic. 2008. tab, graf
Article in Spanish | IBECS | ID: ibc-61129

ABSTRACT

La práctica diaria de la enfermera en hemodiálisis implica riesgos laborales como las punciones accidentales, con el consecuente riesgo de contacto con agentes biológicos, Por tanto, se debe utilizar el mayor número posible de útiles con dispositivos de seguridad. Nuestro objetivo fue evaluar las posibles diferencias entre las agujas con dispositivo de seguridad y las agujas sin dispositivo de seguridad para la punción de las fístulas arterio venosas. Llevamos a cabo un estudio prospectivo experimental con 42 pacientes portadores de fístula antóloga. Se creó un registro de datos relacionados con el “paciente”, el “profesional” y el “material” para valorarlas diferencias existentes entre ambos tipos de aguja. Se analizaron en un total de 35 pacientes en455 sesiones. No hubo diferencias significativas en el uso o no del dispositivo de seguridad en cuanto al dolor provocado, los flujos de sangre, las presiones venosas o el sangrado de las punciones. De 910 punciones con agujas con dispositivo de seguridad en 24 ocasiones se atascó el dispositivo (AU)


The daily practice of nurses working in haemodialysis involves risks such as accidental injections, with the consequent risk of contact with biological agents. Accordingly, the highest possible number of tools with safety devices should be used. Our aim was to evaluate the possible differences between needles fitted with safety devices and needles which did not have such devices in the puncture of arterio venous fistulas. We carried out an experimental prospective study with 42 patients who had antologous fistulas. A register was created of data relating to the “patient”, the “professional” and the “material” in order to evaluate differences between the two different types of needle. A total of 35 patients were analysed over 455 sessions. There were no significant differences in the use or not of the safety device with regard to the pain caused, blood flow, venous pressure or bleeding on puncture. Of 910 injections with safety needles, the device jammed on 24 occasions (AU)


Subject(s)
Humans , Renal Dialysis/instrumentation , Needlestick Injuries/prevention & control , Renal Dialysis/nursing , Universal Precautions , Nursing Care/methods , Renal Insufficiency, Chronic/therapy , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...