Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Chim Acta ; 504: 172-179, 2020 May.
Article in English | MEDLINE | ID: mdl-32001233

ABSTRACT

BACKGROUND: Determining diagnostic thresholds for cardiac troponin assays is key to interpreting their clinical performance. We describe the calculation of 99th percentile upper reference limits (URLs) for the Elecsys® Troponin T Gen 5 (TnT Gen 5) assay. METHODS: Plasma and serum samples from healthy US participants were prospectively evaluated using TnT Gen 5 Short Turn Around Time and 18-min assays on cobas e 411 and cobas e 601 analyzers (Roche Diagnostics); with, up to 8 TnT Gen 5 results per participant. RESULTS: A total of 10,402 TnT Gen 5 results from 1301 participants were included (50.4% female). Across 9 calculation methods, overall 99th percentile URL was 19.2 ng/l (females, 13.5-13.6 ng/l; males, 21.4-22.2 ng/l). Across different sample/assay/analyzer combinations, overall 99th percentile URLs ranged from 18.4-20.2 ng/l. Median TnT Gen 5 results increased with age, were higher in males, and ranged from 3.0-3.7 ng/l across races/ethnicities and from 3.0-3.6 ng/l across body mass index (BMI) classes. Applying additional exclusion criteria (N-terminal pro-brain natriuretic peptide, BMI and estimated glomerular filtration rate) resulted in lower 99th percentile URLs (overall, 16.9 ng/l; females, 11.8 ng/l; males, 18.5 ng/l). CONCLUSION: Our findings facilitate the interpretation of TnT Gen 5 results in US clinical practice.


Subject(s)
Biological Assay , Troponin T , Female , Humans , Male , Racial Groups , Reference Values , United States
2.
Clin Chim Acta ; 495: 522-528, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31152695

ABSTRACT

BACKGROUND: We report the analytical performance of the Elecsys® Troponin T Gen 5 STAT (TnT Gen 5 STAT; Roche Diagnostics) assay. METHODS: Measuring limits/ranges were determined in lithium-heparin plasma samples per Clinical and Laboratory Standards Institute (CLSI) EP17-A2. Precision was evaluated per CLSI EP05-A2 using lithium-heparin plasma/quality control samples on cobas e 411/cobas e 601 analyzers; two duplicated runs per day for 21 days (n = 84). Cross-reactivity with other troponin forms and interference from endogenous substances/drugs was tested; recovery criterion for no cross-reactivity was within ±10%. RESULTS: Coefficients of variation (CV) for repeatability/intermediate precision were 0.7-5.6%/1.4-10.3% (cobas e 411; mean cardiac troponin T [cTnT]: 7.3-9341 ng/L) and 0.7-3.0%/1.5-6.4% (cobas e 601; mean cTnT: 7.4-9455 ng/L). There was no cross-reactivity with skeletal muscle troponin T (≤ 10,000 ng/L), skeletal muscle troponin I (≤ 100,000 ng/L), cardiac troponin I (≤ 10,000 ng/L), or human troponin C (≤ 80,000 ng/L). No interference was observed with biotin (≤ 20 ng/mL) or 34 drugs. CONCLUSION: The TnT Gen 5 STAT assay demonstrated a CV of <10% at the 99th percentile upper reference limit, meeting precision requirements (Fourth Universal Definition of Myocardial Infarction) for high-sensitivity troponin assays.


Subject(s)
Blood Chemical Analysis/methods , Immunoassay/methods , Troponin T/blood , Humans , Limit of Detection , Luminescent Measurements , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...