Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 91
Filter
1.
CJC Open ; 6(4): 649-655, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708054

ABSTRACT

Background: Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS). Methods: A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres. Results: A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation. Conclusions: Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.


Contexte: La stimulation cardiaque sans fil a été établie comme une solution de substitution aux dispositifs transveineux chez certains patients. L'implantation d'un stimulateur cardiaque sans fil est souvent une intervention de novo, mais chez un nombre croissant de patients, ce type de stimulateur est utilisé après l'implantation d'un stimulateur classique. Méthodologie: Une analyse rétrospective de l'efficacité et de l'innocuité de la stimulation cardiaque sans fil dans le contexte de l'implantation d'un stimulateur classique a été réalisée dans deux grands centres suisses. Résultats: Un total de 257 patients consécutifs ayant subi l'implantation d'un stimulateur cardiaque sans fil ont été inclus. Les patients étaient répartis dans deux groupes; le groupe 1 était composé de 233 patients non porteurs d'un stimulateur classique, et le groupe 2, de 24 patients porteurs d'un stimulateur classique in situ. Dans le groupe 2, 20 patients au total (83 %) ont eu besoin d'une extraction de la sonde transveineuse en raison d'une infection, d'un défaut de fonctionnement, ou pour d'autres motifs. Chez 3 patients présentant une infection liée au stimulateur, l'extraction de la sonde et l'implantation d'un stimulateur cardiaque sans fil ont été réalisées simultanément, tandis que dans les 11 autres cas, il s'est écoulé un temps médian de 11,5 jours entre les deux interventions (min.-max. : 2-186 jours). Les paramètres relatifs au dispositif électrique au moment de l'implantation et pendant le suivi n'étaient pas différents entre les deux groupes (moyenne : 12,5 ± 9,3 mois). Huit complications périopératoires importantes (3,1 %) sont survenues (4 cas d'épanchement péricardique, 3 cas d'hémorragie fémorale et 1 cas d'hémorragie intra-abdominale) dans l'ensemble de la cohorte au cours d'une période de 30 jours. Aucune complication ne s'est produite dans le groupe de patients porteurs d'un stimulateur classique. On n'a enregistré aucun cas d'infection, même lorsque l'extraction complète du stimulateur classique infecté a été effectuée avant l'implantation du stimulateur cardiaque sans fil. Conclusions: L'implantation d'un stimulateur cardiaque sans fil chez les patients porteurs d'un stimulateur classique (avec ou sans extraction de ce stimulateur) était une intervention efficace et sûre dans cette population de patients.

2.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38696701

ABSTRACT

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Subject(s)
Defibrillators, Implantable , Electric Countershock , Propensity Score , Registries , Humans , Female , Male , Middle Aged , Aged , Sex Factors , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Factors , Treatment Outcome , Arrhythmias, Cardiac/therapy , Risk Assessment , Europe , Time Factors , Death, Sudden, Cardiac/prevention & control
3.
CJC Open ; 6(2Part A): 96-103, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38585679

ABSTRACT

Background: Impairment of the conduction system is a common complication of transcatheter aortic valve replacement (TAVR), which is typically performed in elderly patients. A leadless pacemaker (LP) may be a suitable option in this frail population, but the available scientific data concerning the efficacy and safety of leadless pacing after TAVR are sparse. The purpose of this analysis was to evaluate the efficacy and safety of LP implantation in patients with relevant bradycardias after TAVR, compared to other indications. Methods: Consecutive patients were retrospectively enrolled. Demographics, background heart diseases, interventional parameters, and follow-up data were collected. Results: A total of 257 consecutive patients who underwent LP implantation were included. In 26 patients, the device was implanted due to bradycardias after TAVR (TAVR group), whereas the remaining 231 patients were in the population without previous TAVR (non-TAVR group). The mean implantation duration (56 ± 22 minutes in the TAVR group vs 48 ± 20 minutes in the non-TAVR group; P = not significant [NS]) and the implantation success rate (100% in the TAVR group vs 98.7% in the non-TAVR group; P = NS) were similar in the 2 cohorts. No significant differences occurred in pacing parameters (sensing, impedance, and threshold, respectively) between the 2 groups, either at implantation or during follow-up. A total of 8 major periprocedural complications (3.1% of patients in total; 3.8% in the TAVR group vs 3.0% in the non-TAVR group; P = NS) occurred within 30 days, without significant difference between the 2 groups. Conclusions: LP implantation appears to be safe and effective in patients after TAVR, and therefore, this procedure is a suitable option for this often old and frail population.


Contexte: L'atteinte du système de conduction cardiaque est une complication courante du remplacement valvulaire aortique par cathéter (RVAC), une intervention habituellement pratiquée chez les patients âgés. Un stimulateur cardiaque sans sonde peut être une option convenable pour cette population fragile, mais les données scientifiques actuelles concernant l'efficacité et l'innocuité de la stimulation sans sonde après un RVAC sont fragmentaires. Cette analyse visait à évaluer l'efficacité et l'innocuité de l'implantation d'un stimulateur cardiaque sans sonde chez des patients atteints de bradycardies pertinentes après un RVAC, comparativement à d'autres indications. Méthodologie: Des patients consécutifs ont été recrutés de manière rétrospective. Les données démographiques, les maladies cardiaques sous-jacentes, les paramètres interventionnels et les données de suivi ont été colligés. Résultats: Un total de 257 patients consécutifs qui se sont fait implanter un stimulateur cardiaque sans sonde ont été inclus. Chez 26 patients, le dispositif a été implanté en raison d'une bradycardie après un RVAC (groupe RVAC), alors que les 231 autres patients formaient la population sans RVAC antérieur (groupe sans RVAC). La durée moyenne de l'intervention d'implantation (56 ± 22 minutes dans le groupe RVAC vs 48 ± 20 minutes dans le groupe sans RVAC; p = non significatif [NS]) et le taux de réussite de l'implantation (100 % dans le groupe RVAC vs 98,7 % dans le groupe sans RVAC; p = NS) étaient similaires dans les deux cohortes. Aucune différence significative n'a été observée dans les paramètres de stimulation (sensibilité, impédance et seuil, respectivement) entre les 2 groupes, que ce soit au moment de l'implantation ou pendant le suivi. Un total de 8 complications périopératoires majeures (3,1 % de l'ensemble des patients; 3,8 % dans le groupe RVAC vs 3,0 % dans le groupe sans RVAC; p = NS) sont survenues dans les 30 jours, sans différence notable entre les 2 groupes. Conclusions: L'implantation d'un stimulateur cardiaque sans sonde semble sûre et efficace après un RVAC; par conséquent, cette intervention représente une option convenable pour cette population souvent âgée et fragile.

4.
J Clin Med ; 13(7)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38610724

ABSTRACT

Background: In the COMPASS trial, the combination of acetylsalicylic acid (ASA) plus 2.5 mg rivaroxaban twice daily (dual-pathway inhibition, DPI) has been shown to be superior to ASA monotherapy for the reduction in ischemic major adverse cardiovascular events (MACEs, i.e., cardiovascular death, stroke, or myocardial infarction). Methods: The international XATOA registry (Xarelto plus Acetylsalicylic acid: Treatment patterns and Outcomes in patients with Atherosclerosis) is a prospective post-approval registry that investigates the cardiovascular outcomes of patients taking ASA plus 2.5 mg rivaroxaban. The aim of this pre-specified analysis was to determine the net clinical outcome (NCO), i.e., a combination of MACEs and bleeding events, of DPI in patients from daily clinical practice. Results: Among the 5615 patients, the presence of multiple risk factors resulted in an increase in the total risk of experiencing an NCO event, e.g., from 1.27% (one risk factor) to 2.18% (two risk factors) and 4.07% (three or more risk factors), respectively, with ischemic MACE representing the primary driver of bleeding complications. Conclusions: In the real-world XATOA registry, the annual rate of NCO events was low and numerically similar to those seen in the treatment group in the randomized COMPASS trial.

5.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584394

ABSTRACT

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
7.
J Clin Med ; 13(7)2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38610667

ABSTRACT

Background: Cardiac resynchronization therapy (CRT) has evolved into an established therapy for patients with chronic heart failure and a wide QRS complex. Data on long-term outcomes over time are scarce and the criteria for implantation remain a subject of investigation. Methods: An international, multicenter, retrospective registry includes 2275 patients who received CRT between 30 November 2000 and 31 December 2019, with a mean follow-up of 3.6 ± 2.7 years. Four time periods were defined, based on landmark trials and guidelines. The combined endpoint was a composite of all-cause mortality, heart transplantation, or left ventricular assist device implantation. Results: The composite endpoint occurred in 656 patients (29.2%). The mean annual implantation rate tripled from 31.5 ± 17.4/year in the first period to 107.4 ± 62.4/year in the last period. In the adjusted Cox regression analysis, the hazard ratio for the composite endpoint was not statistically different between time periods. When compared to sinus rhythm with left bundle branch block (LBBB), a non-LBBB conduction pattern (sinus rhythm: HR 1.51, 95% CI 1.12-2.03; atrial fibrillation: HR 2.08, 95% CI 1.30-3.33) and a QRS duration below 130 ms (HR 1.64, 95% CI 1.29-2.09) were associated with a higher hazard ratio. Conclusions: Despite innovations, an adjusted regression analysis revealed stable overall survival over time, which can at least partially be explained by a shift in patient characteristics.

8.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38449430

ABSTRACT

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Cardiac Pacing, Artificial/adverse effects , Arrhythmias, Cardiac/therapy , Heart Rate/physiology
9.
Heart Rhythm ; 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38432424

ABSTRACT

BACKGROUND: Leadless pacemakers (LPs) capable of VDD pacing allow for atrioventricular synchrony through mechanical sensing of atrial contraction. However, mechanical sensing is less reliable and less predictable than electrical sensing. OBJECTIVE: The purpose of this study was to evaluate P-wave amplitude during sinus rhythm from preoperative 12-lead electrocardiograms (ECGs) as a predictor for atrial mechanical sensing in patients undergoing VDD LP implantation. METHODS: Consecutive patients undergoing VDD LP implantation were included in this 2-center prospective cohort study. ECG parameters were evaluated separately and in combination for association with the signal amplitude of atrial mechanical contraction (A4). RESULTS: Eighty patients (median age 82 years; female 55%; mean body mass index [BMI] 25.8 kg/m2) were included in the study and 61 patients in the A4 signal analysis (19 patients in VVI mode during follow-up). Absolute (aVL, aVF, V1, V2) and BMI-adjusted (I, II, aVL, aVF, aVR, V1, V2) P-wave amplitudes from baseline ECGs demonstrated a statistically significant positive correlation with A4 signal amplitude (all P <.05). A combined P-wave signal amplitude of at least 0.2 mV in V1 and aVL was predictive, with specificity of 83% (95% confidence interval 67%-100%) for A4 signal ≥1 m/s2. We found a significant correlation of A4 signal amplitude and overall atrioventricular synchrony (P = .013). CONCLUSION: P-wave amplitudes in ECG leads aVL and V1 can predict A4 signal amplitude in patients with VDD LP and therefore the probability of successful AV synchronous pacing.

10.
Article in English | MEDLINE | ID: mdl-38345706

ABSTRACT

BACKGROUND: Persistent left superior vena cava (PLSVC) is a rare venous anomaly, affecting 0.3-0.5% of the general population. Cardiac resynchronization therapy (CRT) implantation in patients with PLSVC is challenging due to a complex anatomy. Moreover, data on CRT implantation in this patient population is scarce. Our aim was to report a series of patients with PLSVC and CRT implantation focusing on challenges and pitfalls. METHODS: Electronic medical databases on patients with CRT implantation at the University Heart Centers in Zurich, Switzerland, and Lübeck, Germany, were screened for individuals with a PLSVC. Clinical and demographic characteristics as well as procedural data were reported in all patients. RESULTS: This study presents six cases with a median age of 66 years. CRT implantation was successful in five patients, leading to a reduced QRS duration and improved left ventricular ejection fraction. Atrial fibrillation, ischemic cardiomyopathy, valvular heart disease, and dilated cardiomyopathy were observed in this group as underlying conditions. Specialized tools, such as active fixation left ventricular leads, were utilized. One patient experienced major complications. CONCLUSIONS: This case series shows that although challenging, conventional endovascular CRT implantation is feasible in PLSVC patients. Specialized tools for visualization and fixation may help. Our experiences highlight the importance of preprocedural evaluation of the anatomy and precise intervention planning.

11.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38246594

ABSTRACT

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Cardiomyopathy, Dilated , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Electric Countershock/adverse effects , Arrhythmogenic Right Ventricular Dysplasia/complications , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/therapy , Registries , Treatment Outcome
12.
Eur J Heart Fail ; 26(2): 511-520, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37905357

ABSTRACT

AIM: Cardiac resynchronization therapy (CRT) is a cornerstone in the management of chronic heart failure in patients with a broad or paced QRS. However, data on long-term outcome after upgrade to CRT are scarce. METHODS AND RESULTS: This international, multicentre retrospective registry included 2275 patients who underwent a de novo or upgrade CRT implantation with a mean follow-up of 3.6 ± 2.7 years. The primary composite endpoint included all-cause mortality, heart transplantation, or ventricular assist device implantation. The secondary endpoint was first heart failure admission. Multivariable Cox regression and propensity score matching (PSM) analyses were performed. Patients who underwent CRT upgrade (n = 605, 26.6%) were less likely female (19.7% vs. 28.8%, p < 0.001), more often had ischeemic cardiomyopathy (49.8% vs. 40.2%, p < 0.001), and had worse renal function (median estimated glomerular filtration rate 50.3 ml/min/1.73 m2 [35.8-69.5] vs. 59.9 ml/min/1.73 m2 [43.0-76.5], p < 0.001). The incidence rate of the composite endpoint was 10.8%/year after CRT upgrade versus 7.1%/year for de novo implantations (p < 0.001). PSM for the primary endpoint resulted in 488 pairs. After propensity score matching, upgrade to CRT was associated with a higher chance to reach the composite endpoint (multivariable hazard ratio [HR] 1.35, 95% confidence interval [CI] 1.08-1.70), for both upgrade from pacemaker (multivariable HR 1.33, 95% CI 1.03-1.70) and implantable cardioverter-defibrillator (ICD) (multivariable HR 1.40, 95% CI 1.01-1.95). PSM for the secondary endpoint resulted in 277 pairs. After PSM, upgrade to CRT was associated with a higher chance for heart failure admission (HR 1.74, 95% CI 1.26-2.41). CONCLUSION: In this retrospective analysis, the outcome of patients who underwent upgrades to CRT differed significantly from patients who underwent de novo CRT implantation, particularly for upgrades from ICD. Importantly, this difference in outcome does not imply a causal relation between therapy and outcome but rather a difference between two different patient populations.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Female , Cardiac Resynchronization Therapy/methods , Propensity Score , Retrospective Studies , Treatment Outcome
13.
J Clin Med ; 12(16)2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37629216

ABSTRACT

BACKGROUND: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. METHODS: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. RESULTS: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14-1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). CONCLUSIONS: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.

14.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37481220

ABSTRACT

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

15.
Cardiology ; 148(5): 441-447, 2023.
Article in English | MEDLINE | ID: mdl-37487479

ABSTRACT

INTRODUCTION: Long-term complication rates in standard transvenous pacemakers are reported around 4-12% with a higher incidence in the elderly population. We report our experience in octogenarians undergoing leadless pacemaker implantation in two large-volume centers in Switzerland. METHODS: Consecutive patients undergoing leadless pacemaker implantation at two Swiss large volume centers (University Hospital Zurich, Zurich and Cardiocentro Ticino Institute, Lugano) between October 2015 and March 2020 were included in this retrospective analysis. Demographic information, clinical data, and procedural characteristics were recorded at the day of implantation and during follow-up. RESULTS: Two hundred and twenty patients (mean age 80.6 ± 7.7 years, male 66%) were included. The main indication for pacemaker implantation was slow ventricular rate atrial fibrillation (111 of 220 patients, 50.4%). Out of the 220 patients, 124 (56.3%) were ≥80 years. Overall successful implantation rate was 98.6%. In the octogenarian population, the median procedure time (45 ± 20.2 min vs. 40 ± 19.6 min, p = 0.03) and radiation duration (6.1 ± 8.2 min vs. 5.0 ± 7.2 min, p = 0.03) were longer compared to patients <80 years. Major complications (2.7%, n = 6) and device measurements during follow-up were similar between patients ≥80 and <80 years. CONCLUSION: Implantation of a leadless pacemaker device in octogenarians is safe and effective with a similarly low complication rate compared to non-octogenarians.


Subject(s)
Atrial Fibrillation , Pacemaker, Artificial , Aged, 80 and over , Humans , Male , Aged , Octogenarians , Retrospective Studies , Treatment Outcome , Atrial Fibrillation/therapy , Ventricular Fibrillation , Equipment Design
16.
J Clin Med ; 12(14)2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37510929

ABSTRACT

INTRODUCTION: Data on peri-operative management of direct-acting oral anticoagulants (DOACs) during transcatheter pacing leadless system (TPS) implantations remain limited. This study aimed to evaluate a standardized DOAC management regime consisting of interruption of a single dose prior to implantation and reinitiation within 6-24 h; also, patient clinical characteristics associated with this approach were identified. METHOD: Consecutive patients undergoing standard TPS implantation procedures from two Swiss tertiary centers were included. DOAC peri-operative management included the standardized approach (Group 1A) or other approaches (Group 1B). RESULTS: Three hundred and ninety-two pts (mean age 81.4 ± 7.3 years, 66.3% male, left ventricular ejection fraction 55.5 ± 9.6%) underwent TPS implantation. Two hundred and eighty-two pts (71.9%) were under anticoagulation therapy; 192 pts were treated with DOAC; 90 pts were under vitamin-K antagonist. Patients treated with DOAC less often had structural heart disease, diabetes mellitus, and advanced renal failure. The rate of major peri-procedural complications did not differ between groups 1A (n = 115) and 1B (n = 77) (2.6% and 3.8%, p = 0.685). Compared to 1B, 1A patients were implanted with TPS for slow ventricular rate atrial fibrillation (AF) (p = 0.002), in a better overall clinical status, and implanted electively (<0.001). CONCLUSIONS: Standardized peri-procedural DOAC management was more often implemented for elective TPS procedures and did not seem to increase bleeding or thromboembolic adverse events.

17.
Front Cardiovasc Med ; 10: 1205966, 2023.
Article in English | MEDLINE | ID: mdl-37346289

ABSTRACT

Aim: To investigate the clinical significance of right atrial mapping prior to cavotricuspid isthmus (CTI) ablation in patients with typical atrial flutter (AFL). Methods: Clinical and ablation parameters were retrospectively assessed and compared in patients undergoing CTI ablation with or without a first-step right atrial mapping (FRAM) by using the CARTO 3D mapping system. Results: CTI block by radiofrequency ablation (RFA) was achieved in all 143 patients. In the FRAM group there was a shorter ablation duration and fluoroscopy exposure compared with the non-FRAM group. CHA2DS2-VASc score was associated with higher ablation durations, more ablation applications and increased fluoroscopy exposure. Body mass index (BMI) was associated with longer ablation duration and more ablation applications. Furthermore, patients with reduced left ventricular ejection fraction (LVEF) had longer ablation durations and more fluoroscopy exposure. One patient in the non-FRAM group developed cardiac effusion after ablation. None of the patients had recurrence after 6 months of follow-up. Conclusions: Patients with high BMI, high CHA2DS2-VASc score and reduced LVEF may benefit from the FRAM approach by reducing ablation duration, number of ablation applications and fluoroscopy exposure.

18.
J Cardiovasc Electrophysiol ; 34(8): 1738-1743, 2023 08.
Article in English | MEDLINE | ID: mdl-37343057

ABSTRACT

INTRODUCTION: Transvenous lead extraction has become a frequent procedure in the context of device lead management and various tools are available. The aim of this study was to investigate the efficacy and safety of the novel short rotating dilator sheath TightRailTM Sub-C (Sub-C) in transvenous lead extraction. METHODS: For this retrospective single-center analysis, we included consecutive patients undergoing transvenous lead extraction using the Sub-C from January 2018 until February 2020 at the University Heart Center Zurich. RESULTS: A total of 87 leads were extracted within 45 patients using the Sub-C extraction sheath. The mean dwell time of the leads was 112 ± 9.1 months. Complete procedural success was achieved in 95.6% (43/45) and clinical procedural success in 97.8% (44/45). Two major complications (4.4%, 2/45) occurred, but neither was directly related to the Sub-C. CONCLUSION: This retrospective single-center analysis suggests that transvenous lead extraction with a routine use of the TightRailTM Sub-C extraction sheath is a safe strategy resulting in high success rates that may offer useful theoretical benefits. Future studies are needed to evaluate the incremental benefit of a routine use of short extraction sheaths including the Sub-C during TLE procedures.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Retrospective Studies , Device Removal/methods , Equipment Design , Equipment Failure , Treatment Outcome
19.
J Clin Med ; 12(11)2023 May 26.
Article in English | MEDLINE | ID: mdl-37297892

ABSTRACT

AIMS: Association of two-(2D) and three-dimensional (3D) left atrial strain (LAS) and low-voltage area (LVA) with recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI) was assessed. METHODS AND RESULTS: 3D LAS, 2D LAS, and LVA were obtained in 93 consecutive patients undergoing PVI and recurrence of AF was analyzed prospectively. AF recurred in 12 patients (13%). The 3D left atrial reservoir strain (LARS) and pump strain (LAPS) were lower in patients with recurrent AF than without (p = 0.008 and p = 0.009, respectively). In univariable Cox regression, 3D LARS or LAPS were associated with recurrent AF (LARS: HR = 0.89 (0.81-0.99), p = 0.025; LAPS: HR = 1.40 (1.02-1.92), p = 0.040), while other values were not. Association of 3D LARS or LAPS with recurrent AF was independent of age, body mass index, arterial hypertension, left ventricular ejection fraction, and end-diastolic volume index and left atrial volume index in multivariable models. Kaplan-Meier curves revealed that patients with 3D LAPS < -5.9% did not exhibit recurrent AF, while those >-5.9% had a significant risk of recurrent AF. CONCLUSIONS: 3D LARS and LAPS were associated with recurrent AF after PVI. Association of 3D LAS was independent of relevant clinical and echocardiographic parameters and improved their predictive value. Hence, they may be applied for outcome prediction in patients undergoing PVI.

20.
J Clin Med ; 12(6)2023 Mar 14.
Article in English | MEDLINE | ID: mdl-36983262

ABSTRACT

INTRODUCTION: Transvenous lead extractions are increasingly performed for malfunction or infection of cardiac implantable electronic devices, but they harvest a potential for complications and suboptimal success. Apart from multicenter registries and reports from highly experienced single centers, the outcome in individual newly developing high-volume centers starting a lead extraction program is less well established. We aimed to evaluate the clinical and radiological success and complication rate at our center, having started a lead extraction program less than a decade ago. METHODS: We retrospectively analyzed patients who underwent transvenous lead extraction at the University Hospital Zurich from 2013 to 2021 regarding success as well as complications and compared our results to previously reported outcome rates. RESULTS: A total of 346 patients underwent 350 transvenous lead extractions from January 2013 to December 2021. Combined radiological success was achieved in 97.7% and clinical success in 96.0% of interventions. Procedure-related major complications occurred in 13 patients (3.7%). Death within 30 days after transvenous lead extractions occurred in 13 patients (3.7%), with a procedure-related mortality of 1.4% (five patients). SUMMARY: Transvenous lead extractions in newly developing high-volume centers can be performed with high clinical and radiological success rates, but procedure-related major complications may affect a relevant number of patients. Compared to large single or multicenter registries of experienced centers, the success rate may be lower and the complication rate higher in centers newly starting with lead extraction, which may have important implications for patient selection, procedural planning, proctoring, and safety measures.

SELECTION OF CITATIONS
SEARCH DETAIL
...