Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 87(8): 083307, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27587113

ABSTRACT

We describe a very compact (0.9 m high, 0.4 m diameter, 40 kg) battery operable neutron scatter camera designed for field deployment. Unlike most other systems, the configuration of the sixteen liquid-scintillator detection cells are arranged to provide omnidirectional (4π) imaging with sensitivity comparable to a conventional two-plane system. Although designed primarily to operate as a neutron scatter camera for localizing energetic neutron sources, it also functions as a Compton camera for localizing gamma sources. In addition to describing the radionuclide source localization capabilities of this system, we demonstrate how it provides neutron spectra that can distinguish plutonium metal from plutonium oxide sources, in addition to the easier task of distinguishing AmBe from fission sources.

2.
ACS Nano ; 6(9): 7770-80, 2012 Sep 25.
Article in English | MEDLINE | ID: mdl-22827439

ABSTRACT

The precise perturbation of gene circuits and the direct observation of signaling pathways in living cells are essential for both fundamental biology and translational medicine. Current optogenetic technology offers a new paradigm of optical control for cells; however, this technology relies on permanent genomic modifications with light-responsive genes, thus limiting dynamic reconfiguration of gene circuits. Here, we report precise control of perturbation and reconfiguration of gene circuits in living cells by optically addressable siRNA-Au nanoantennas. The siRNA-Au nanoantennas fulfill dual functions as selectively addressable optical receivers and biomolecular emitters of small interfering RNA (siRNA). Using siRNA-Au nanoantennas as optical inputs to existing circuit connections, photonic gene circuits are constructed in living cells. We show that photonic gene circuits are modular, enabling subcircuits to be combined on-demand. Photonic gene circuits open new avenues for engineering functional gene circuits useful for fundamental bioscience, bioengineering, and medical applications.


Subject(s)
Gene Regulatory Networks/genetics , Gene Regulatory Networks/radiation effects , Genetic Engineering/methods , Gold/chemistry , Nanostructures/chemistry , RNA, Small Interfering/genetics , RNA, Small Interfering/radiation effects , Gold/radiation effects , Light , Materials Testing , Nanostructures/radiation effects
3.
Anal Chem ; 81(9): 3261-9, 2009 May 01.
Article in English | MEDLINE | ID: mdl-19323537

ABSTRACT

The ability to monitor cell signaling events is crucial to the understanding of immune defense against invading pathogens. Conventional analytical techniques such as flow cytometry, microscopy, and Western blot are powerful tools for signaling studies. Nevertheless, each approach is currently stand-alone and limited by multiple time-consuming and labor-intensive steps. In addition, these techniques do not provide correlated signaling information on total intracellular protein abundance and subcellular protein localization. We report on a novel phosphoFlow Chip (pFC) that relies on monolithic microfluidic technology to rapidly conduct signaling studies. The pFC platform integrates cell stimulation and preparation, microscopy, and subsequent flow cytometry. pFC allows host-pathogen phosphoprofiling in 30 min with an order of magnitude reduction in the consumption of reagents. For pFC validation, we monitor the mitogen-activated protein kinases ERK1/2 and p38 in response to Escherichia coli lipopolysaccharide (LPS) stimulation of murine macrophage cells (RAW 264.7). pFC permits ERK1/2 phosphorylation monitoring starting at 5 s after LPS stimulation, with phosphorylation observed at 5 min. In addition, ERK1/2 phosphorylation is correlated with subsequent recruitment into the nucleus, as observed from fluorescence microscopy performed on cells upstream of flow cytometric analysis. The fully integrated cell handling has the added advantage of reduced cell aggregation and cell loss, with no detectable cell activation. The pFC approach is a step toward unified, automated infrastructure for high-throughput systems biology.


Subject(s)
Macrophages/metabolism , Microfluidic Analytical Techniques/methods , Systems Integration , Animals , Automation , Cell Adhesion , Cell Line , Cell Membrane Permeability , Flow Cytometry , Lipopolysaccharides/immunology , Macrophage Activation , Macrophages/cytology , Macrophages/immunology , Mice , Microscopy, Fluorescence , Mitogen-Activated Protein Kinase 3/metabolism , Phosphorylation , Pressure , Signal Transduction , Systems Biology , Time Factors , Toll-Like Receptor 4/metabolism , p38 Mitogen-Activated Protein Kinases/metabolism
4.
J Pharmacol Exp Ther ; 323(2): 422-30, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17698974

ABSTRACT

There is currently little information regarding the localization of UDP-glucuronosyltransferases (UGTs) in human renal cortex and medulla, and the functional contribution of renal UGTs to drug glucuronidation remains poorly defined. Using human kidney sections and human kidney cortical microsomes (HKCM) and human kidney medullary microsomes (HKMM), we combined immunohistochemistry to investigate UGT1A and UGT2B7 expression with in vitro microsomal studies to determine the kinetics of S-naproxen acyl glucuronidation. With the exception of the glomerulus, Bowman's capsule, and renal vasculature, UGT1A proteins and UGT2B7 were expressed throughout the proximal and distal convoluted tubules, the loops of Henle, and the collecting ducts. Additionally, UGT1A and UGT2B7 expression was demonstrated in the macula densa, supporting a potential role of UGTs in regulating aldosterone. Consistent with the immunohistochemical data, S-naproxen acyl glucuronidation was catalyzed by HKCM and HKMM. Kinetic data were well described by the two-enzyme Michaelis-Menten equation. K(m) values for the high-affinity components were 34 +/- 14 microM (HKCM) and 45 +/- 14 microM (HKMM). Fluconazole inhibited the high-affinity component establishing UGT2B7 as the enzyme responsible for S-naproxen glucuronidation in cortex and medulla. The low-affinity component was relatively unaffected by fluconazole (<15% inhibition), supporting the presence of other UGTs with S-naproxen glucuronidation capacity (e.g., UGT1A6 and UGT1A9) in cortex and medulla. We postulate that the ubiquitous distribution of UGTs in mammalian kidney may buffer physiological responses to endogenous mediators, but at the same time competitive xenobiotic-endobiotic interactions may provide an explanation for the adverse renal effects of drugs, including nonsteroidal anti-inflammatory drugs.


Subject(s)
Glucuronides/metabolism , Glucuronosyltransferase/analysis , Kidney Cortex/enzymology , Kidney Medulla/enzymology , Naproxen/analogs & derivatives , Naproxen/metabolism , Humans , Immunohistochemistry , Kinetics , Male
5.
Ann N Y Acad Sci ; 1098: 362-74, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17435142

ABSTRACT

While many point-of-care (POC) diagnostic methods have been developed for blood-borne analytes, development of saliva-based POC diagnostics is in its infancy. We have developed a portable microfluidic device for detection of potential biomarkers of periodontal disease in saliva. The device performs rapid microfluidic chip-based immunoassays (<3-10 min) with low sample volume requirements (10 microL) and appreciable sensitivity (nM-pM). Our microfluidic method facilitates hands-free saliva analysis by integrating sample pretreatment (filtering, enrichment, mixing) with electrophoretic immunoassays to quickly measure analyte concentrations in minimally pretreated saliva samples. The microfluidic chip has been integrated with miniaturized electronics, optical elements, such as diode lasers, fluid-handling components, and data acquisition software to develop a portable, self-contained device. The device and methods are being tested by detecting potential biomarkers in saliva samples from patients diagnosed with periodontal disease. Our microchip-based analysis can readily be extended to detection of biomarkers of other diseases, both oral and systemic, in saliva and other oral fluids.


Subject(s)
Lab-On-A-Chip Devices , Microfluidics/instrumentation , Periodontal Diseases/diagnosis , Periodontal Diseases/metabolism , Saliva/chemistry , Humans , Microchip Analytical Procedures/methods , Microfluidics/methods
6.
Proc Natl Acad Sci U S A ; 104(13): 5268-73, 2007 Mar 27.
Article in English | MEDLINE | ID: mdl-17374724

ABSTRACT

At present, point-of-care (POC) diagnostics typically provide a binary indication of health status (e.g., home pregnancy test strip). Before anticipatory use of diagnostics for assessment of complex diseases becomes widespread, development of sophisticated bioassays capable of quantitatively measuring disease biomarkers is necessary. Successful translation of new bioassays into clinical settings demands the ability to monitor both the onset and progression of disease. Here we report on a clinical POC diagnostic that enables rapid quantitation of an oral disease biomarker in human saliva by using a monolithic disposable cartridge designed to operate in a compact analytical instrument. Our microfluidic method facilitates hands-free saliva analysis by integrating sample pretreatment (filtering, enrichment, mixing) with electrophoretic immunoassays to quickly measure analyte concentrations in minimally pretreated saliva samples. Using 20 microl of saliva, we demonstrate rapid (<10 min) measurement of the collagen-cleaving enzyme matrix metalloproteinase-8 (MMP-8) in saliva from healthy and periodontally diseased subjects. In addition to physiologically measurable indicators of periodontal disease, conventional measurements of salivary MMP-8 were used to validate the microfluidic assays described in this proof-of-principle study. The microchip-based POC diagnostic demonstrated is applicable to rapid, reliable measurement of proteinaceous disease biomarkers in biological fluids.


Subject(s)
Chemistry, Clinical/methods , Electrophoresis/methods , Immunoassay/methods , Microfluidics/methods , Periodontal Diseases/diagnosis , Saliva/metabolism , Biomarkers/metabolism , Collagen/metabolism , Computers, Handheld , Enzyme-Linked Immunosorbent Assay , Equipment Design , Humans , Image Processing, Computer-Assisted , Matrix Metalloproteinase 8/metabolism , Periodontal Diseases/metabolism , Ultraviolet Rays
7.
Anal Chem ; 78(14): 4976-84, 2006 Jul 15.
Article in English | MEDLINE | ID: mdl-16841920

ABSTRACT

The potential of integration of functions in microfluidic chips is demonstrated by implementing on-chip preconcentration of proteins prior to on-chip protein sizing by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Two polymeric elements-a thin (approximately 50 microm) size exclusion membrane for preconcentration and a longer (approximately cm) porous monolith for protein sizing-were fabricated in situ using photopolymerization. Contiguous placement of the two polymeric elements in the channels of a microchip enabled simple and zero dead volume integration of the preconcentration with SDS-PAGE. The size exclusion membrane was polymerized in the injection channel using a shaped laser beam, and the sizing monolith was cast by photolithography using a mask and UV lamp. Proteins injected electrophoretically were trapped on the upstream side of the size exclusion membrane (MW cutoff approximately 10 kDa) and eluted off the membrane by reversing the electric field. Subsequently, the concentrated proteins were separated in a cross-linked polyacrylamide monolith that was patterned contiguous to the size exclusion membrane. The extent of protein preconcentration is easily tuned by varying the voltage during injection or by controlling the sample volume loaded. Electric fields applied across the nanoporous membrane resulted in a concentration polarization effect evidenced by decreasing current over time and irreproducible migration of proteins during sizing. To minimize the concentration polarization effect, sieving gels were polymerized only on the separation side of the membrane, and an alternate electrical current path was employed, bypassing the membrane, for most of the elution and separation steps. Electrophoretically sweeping a fixed sample volume against the membrane yields preconcentration factors that are independent of protein mobility. The volume sweeping method also avoids biased protein loading from concentration polarization and sample matrix variations. Mobilities of the concentrated proteins were log-linear with respect to molecular weight, demonstrating the suitability of this approach for protein sizing. Proteins were concentrated rapidly (<5 min) over 1000-fold followed by high-resolution separation in the sieving monolith. Proteins with concentrations as low as 50 fM were detectable with 30 min of preconcentration time. The integrated preconcentration-sizing approach facilitates analysis of low-abundant proteins that cannot be otherwise detected. Moreover, the integrated preconcentration-analysis approach employing in situ formation of photopatterned polymeric elements provides a generic, inexpensive, and versatile method to integrate functions at chip level and can be extended to lowering of detection limits for other applications such as DNA analysis and clinical diagnostics.


Subject(s)
Acrylic Resins/chemistry , Cross-Linking Reagents/chemistry , Electrophoresis, Polyacrylamide Gel/methods , Microchip Analytical Procedures/methods , Proteins/analysis , Proteins/chemistry , Nanostructures , Photochemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...