Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
4.
Br Heart J ; 43(1): 56-66, 1980 Jan.
Article in English | MEDLINE | ID: mdl-6965585

ABSTRACT

The predictive accuracy of exercise thallium-201 (201Tl) myocardial scintigraphy in the evaluation of aortocoronary bypass graft surgery was assessed in 48 patients undergoing angiographic investigation 15 months (mean time) after myocardial revascularisation. 201Tl scintigrams detected 61 out of 77 (79%) patent grafts but only 21 out of 42 (50%) occluded grafts, though, for grafts supplying non-infarcted myocardium, the predictive accuracy of graft patency and graft occlusion was 85 per cent and 81 per cent, respectively. Stress electrocardiography failed to detect 15 out of 21 patients with scintigraphic evidence of regional myocardial ischaemia. Residual ischaemia in the proximal left anterior descending coronary distribution was commonly detected in 201Tl scintigrams despite a patent, well-functioning left anterior descending graft to the distal coronary segment. Additional residual ischaemia attributable to ungrafted coronary disease was detected by scintigraphy in 32 (67%) patients and most commonly occurred in the distribution of the diagonal branch of the left anterior descending especially in the presence of a patent distal left anterior descending graft. Thus, independent grafts to the diagonal branch of the left anterior descending are recommended at the time of aortocoronary bypass graft surgery.


Subject(s)
Coronary Artery Bypass , Heart/diagnostic imaging , Postoperative Complications/diagnostic imaging , Adult , Angiocardiography , Coronary Circulation , Coronary Disease/diagnostic imaging , Coronary Disease/physiopathology , False Negative Reactions , Female , Humans , Male , Middle Aged , Physical Exertion , Radioisotopes , Radionuclide Imaging , Thallium
5.
Lancet ; 2(8154): 1248, 1979 Dec 08.
Article in English | MEDLINE | ID: mdl-92662
6.
Lancet ; 2(8138): 320-3, 1979 Aug 18.
Article in English | MEDLINE | ID: mdl-89388

ABSTRACT

50 normotensive subjects (22 controls with no cardiac disease, 24 patients with coronary heart-disease, and 4 with early cardiomyopathy) were investigated with gated cardiac blood-pool scintigraphy before and during cold pressor stimulation. The controls had no change or a significant rise (p less than 0.005) in left ventricular ejection fraction and preserved normal myocardial-wall motion, whereas patients with coronary-artery disease or cardiomyopathy had a significant fall (p less than 0.001) in left ventricular ejection fraction and many developed abnormal regional wall motion despite the absence of angina pectoris. Cold pressor gated cardiac blood-pool studies were more sensitive than single-lead exercise electrocardiography (p = 0.03) in the detection of patients with severe coronary-artery disease without previous myocardial infarction.


Subject(s)
Cardiomyopathies/diagnostic imaging , Cold Temperature , Coronary Disease/diagnostic imaging , Radionuclide Imaging/methods , Adolescent , Adult , Blood Pressure , Cardiac Output , Cardiomyopathies/physiopathology , Coronary Disease/physiopathology , Erythrocytes , Evaluation Studies as Topic , Exercise Test , Female , Heart Rate , Humans , Isotope Labeling , Male , Middle Aged , Technetium
SELECTION OF CITATIONS
SEARCH DETAIL
...