Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Dtsch Med Wochenschr ; 149(10): 587-591, 2024 May.
Article in German | MEDLINE | ID: mdl-38657598

ABSTRACT

Probably everyone who works in emergency medicine has been in the situation of having to insert a peripheral vein under time pressure in difficult venous conditions. So what do I do if I don't succeed? Establish a peripheral venous catheter? In recent years, the intraosseous approach has become increasingly popular as an alternative procedure. In this article, you will be guided step by step through the creation of an intraosseous access.


Subject(s)
Infusions, Intraosseous , Humans , Infusions, Intraosseous/methods , Catheterization, Peripheral/methods
2.
World J Crit Care Med ; 10(6): 323-333, 2021 Nov 09.
Article in English | MEDLINE | ID: mdl-34888158

ABSTRACT

Coronavirus disease 2019 (COVID-19) related acute respiratory distress syndrome (ARDS) is a severe complication of infection with severe acute respiratory syndrome coronavirus 2, and the primary cause of death in the current pandemic. Critically ill patients often undergo extracorporeal membrane oxygenation (ECMO) therapy as the last resort over an extended period. ECMO therapy requires sedation of the patient, which is usually achieved by intravenous administration of sedatives. The shortage of intravenous sedative drugs due to the ongoing pandemic, and attempts to improve treatment outcome for COVID-19 patients, drove the application of inhaled sedation as a promising alternative for sedation during ECMO therapy. Administration of volatile anesthetics requires an appropriate delivery. Commercially available ones are the anesthetic gas reflection systems AnaConDa® and MIRUSTM, and each should be combined with a gas scavenging system. In this review, we describe respiratory management in COVID-19 patients and the procedures for inhaled sedation during ECMO therapy of COVID-19 related ARDS. We focus particularly on the technical details of administration of volatile anesthetics. Furthermore, we describe the advantages of inhaled sedation and volatile anesthetics, and we discuss the limitations as well as the requirements for safe application in the clinical setting.

3.
PLoS One ; 15(12): e0244330, 2020.
Article in English | MEDLINE | ID: mdl-33373378

ABSTRACT

INTRODUCTION: Reduced antiplatelet activity of aspirin (ALR) or clopidogrel (CLR) is associated with an increased risk of thromboembolic events. The reported prevalence data for low-responders vary widely and there have been few investigations in vascular surgery patients even though they are at high risk for thromb-embolic complications. The aim of this prospective observational monocentric study was to elucidate possible changes in ALR or CLR after common vascular procedures. METHODS: Activity of aspirin and clopidogrel was measured by impedance aggregometry using a multiple electrode aggregometer (Multiplate®). Possible risk factors for ALR or CLR were identified by demographical, clinical data and laboratory parameters. In addition, a follow-up aggregometry was performed after completion of the vascular procedure to identify changes in antiplatelet response. RESULTS: A total of 176 patients taking antiplatelet medications aspirin and/or clopidogrel with peripheral artery disease (PAD) and/or carotid stenosis (CS) were included in the study. The prevalence of ALR was 13.1% and the prevalence of CLR was 32% in the aggregometry before vascular treatment. Potential risk factors identified in the aspirin group were concomitant insulin medication (p = 0.0006) and elevated C-reactive protein (CRP) (p = 0.0021). The overall ALR increased significantly postoperatively to 27.5% (p = 0.0006); however, there was no significant change in CLR that was detected. In a subgroup analysis elevation of the platelet count was associated with a post-procedure increase of ALR incidence. CONCLUSION: The incidence of ALR in vascular surgery patients increases after vascular procedures. An elevated platelet count was detected as a risk factor. Further studies are necessary to analyse this potential influence on patency rates of vascular reconstructions.


Subject(s)
Aspirin/administration & dosage , Carotid Stenosis/surgery , Clopidogrel/administration & dosage , Peripheral Arterial Disease/surgery , Platelet Aggregation Inhibitors/administration & dosage , Vascular Surgical Procedures/adverse effects , Aged , Aged, 80 and over , Aspirin/therapeutic use , Clopidogrel/therapeutic use , Empirical Research , Female , Humans , Male , Perioperative Care/instrumentation , Platelet Aggregation Inhibitors/therapeutic use , Platelet Count , Prevalence , Prospective Studies , Risk Assessment , Treatment Outcome
4.
BMC Anesthesiol ; 19(1): 148, 2019 08 09.
Article in English | MEDLINE | ID: mdl-31399025

ABSTRACT

BACKGROUND: Real-time photoacoustic gas monitoring is used for personnel exposure and environmental monitoring, but its accuracy varies when organic solvents such as alcohol contaminate measurements. This is problematic for anesthetic gas measurements in hospitals, because most disinfectants contain alcohol, which could lead to false-high gas concentrations. We investigated the cross-sensitivities of the photoacoustic gas monitor Innova 1412 (AirTech Instruments, LumaSense, Denmark) against alcohols and alcoholic disinfectants while measuring sevoflurane, desflurane and isoflurane in a laboratory and in hospital during surgery. METHODS: 25 mL ethyl alcohol was distributed on a hotplate. An optical filter for isoflurane was used and the gas monitor measured the 'isoflurane' concentration for five minutes with the measuring probe fixed 30 cm above the hotplate. Then, 5 mL isoflurane was added vaporized via an Anesthetic Conserving Device (Sedana Medical, Uppsala, Sweden). After one-hour measurement, 25 mL isopropyl alcohol, N-propanol, and two alcoholic disinfectants were subsequently added, each in combination with 5 mL isoflurane. The same experiment was in turn performed for sevoflurane and desflurane. The practical impact of the cross-sensitivity was investigated on abdominal surgeons who were exposed intraoperatively to sevoflurane. A new approach to overcome the gas monitor's cross-sensitivity is presented. RESULTS: Cross-sensitivity was observed for all alcohols and its strength characteristic for the tested agent. Simultaneous uses of anesthetic gases and alcohols increased the concentrations and the recovery times significantly, especially while sevoflurane was utilized. Intraoperative measurements revealed mean and maximum sevoflurane concentrations of 0.61 ± 0.26 ppm and 15.27 ± 14.62 ppm. We replaced the cross-sensitivity peaks with the 10th percentile baseline of the anesthetic gas concentration. This reduced mean and maximum concentrations significantly by 37% (p < 0.001) and 86% (p < 0.001), respectively. CONCLUSION: Photoacoustic gas monitoring is useful to detect lowest anesthetic gases concentrations, but cross-sensitivity caused one third falsely high measured mean gas concentration. One possibility to eliminate these peaks is the recovery time-based baseline approach. Caution should be taken while measuring sevoflurane, since marked cross-sensitivity peaks are to be expected.


Subject(s)
Air Pollutants, Occupational/analysis , Anesthetics, Inhalation/analysis , Disinfectants/analysis , Environmental Monitoring , Occupational Exposure/analysis , Photoacoustic Techniques , 1-Propanol/analysis , 2-Propanol/analysis , Desflurane/analysis , Ethanol/analysis , Humans , Isoflurane/analysis , Operating Rooms , Sevoflurane/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...