1.
Magn Reson Med ; 81(3): 2064-2071, 2019 03.
Article in English | MEDLINE | ID: mdl-30329181

ABSTRACT

PURPOSE: The non-uniform fast Fourier transform (NUFFT) involves interpolation of non-uniformly sampled Fourier data onto a Cartesian grid, an interpolation that is slowed by complex, non-local data access patterns. A faster NUFFT would increase the clinical relevance of the plethora of advanced non-Cartesian acquisition methods. METHODS: Here we customize the NUFFT procedure for a radial trajectory and GPU architecture to eliminate the bottlenecks encountered when allowing for arbitrary trajectories and hardware. We call the result TRON, for TRajectory Optimized NUFFT. We benchmark the speed and accuracy TRON on a Shepp-Logan phantom and on whole-body continuous golden-angle radial MRI. RESULTS: TRON was 6-30× faster than the closest competitor, depending on test data set, and was the most accurate code tested. CONCLUSIONS: Specialization of the NUFFT algorithm for a particular trajectory yielded significant speed gains. TRON can be easily extended to other trajectories, such as spiral and PROPELLER. TRON can be downloaded at http://github.com/davidssmith/TRON.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Optic Nerve/diagnostic imaging , Algorithms , Deglutition , Esophagus/diagnostic imaging , Fourier Analysis , Humans , Hypopharynx/diagnostic imaging , Male , Mouth/diagnostic imaging , Phantoms, Imaging , Programming Languages , Reproducibility of Results , Software , Whole Body Imaging
2.
J Med Imaging (Bellingham) ; 2(4): 046001, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26702407

ABSTRACT

Beyond estimation of depot volumes, quantitative analysis of adipose tissue properties could improve understanding of how adipose tissue correlates with metabolic risk factors. We investigated whether the fat signal fraction (FSF) derived from quantitative fat-water magnetic resonance imaging (MRI) scans at 3.0 T correlates to CT Hounsfield units (HU) of the same tissue. These measures were acquired in the subcutaneous white adipose tissue (WAT) at the umbilical level of 21 healthy adult subjects. A moderate correlation exists between MRI- and CT-derived WAT values for all subjects, [Formula: see text], [Formula: see text], with a slope of [Formula: see text], (95% CI [Formula: see text]), indicating that a decrease of 1 HU equals a mean increase of 0.38% FSF. We demonstrate that FSF estimates obtained using quantitative fat-water MRI techniques correlate with CT HU values in subcutaneous WAT, and therefore, MRI-based FSF could be used as an alternative to CT HU for assessing metabolic risk factors.

3.
J Magn Reson ; 210(2): 218-27, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21458339

ABSTRACT

Dynamic B(0) shimming (DS) can produce better field homogeneity than static global shimming by dynamically updating slicewise shim values in a multislice acquisition. The performance of DS however is limited by eddy current fields produced by the switching of 2nd and 3rd order unshielded shims. In this work, we present a novel method of eddy field compensation (EFC) applied to higher order shim induced eddy current fields in multislice DS. This method does not require shim shielding, extra hardware for eddy current compensation or subject specific prescanning. The interactions between shim harmonics are modeled assuming steady state of the medium and long time constant, cross and self term eddy fields in a DS experiment and 'correction factors' characterizing the entire set of shim interactions are derived. The correction factors for a given time between shim switches are shown to be invariable with object scanned, shim switching pattern and actual shim values, allowing for their generalized prospective use. Phantom and human head, 2nd and 3rd order DS experiments performed without any hardware eddy current compensation using the technique show large reductions in field gradients and offsets leading to significant improvements in image quality. This method holds promise as an alternative to expensive hardware based eddy current compensation required in 2nd and 3rd order DS.


Subject(s)
Brain Mapping/methods , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Software , Calibration , Humans , Least-Squares Analysis , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging