Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bone Joint J ; 97-B(10): 1328-37, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26430006

ABSTRACT

We investigated the changes seen on serial metal artefact reduction magnetic resonance imaging scans (MARS-MRI) of metal-on-metal total hip arthroplasties (MoM THAs). In total 155 THAs, in 35 male and 100 female patients (mean age 70.4 years, 42 to 91), underwent at least two MRI scans at a mean interval of 14.6 months (2.6 to 57.1), at a mean of 48.2 months (3.5 to 93.3) after primary hip surgery. Scans were graded using a modification of the Oxford classification. Progression of disease was defined as an increase in grade or a minimum 10% increase in fluid lesion volume at second scan. A total of 16 hips (30%) initially classified as 'normal' developed an abnormality on the second scan. Of those with 'isolated trochanteric fluid' 9 (47%) underwent disease progression, as did 7 (58%) of 'effusions'. A total of 54 (77%) of hips initially classified as showing adverse reactions to metal debris (ARMD) progressed, with higher rates of progression in higher grades. Disease progression was associated with high blood cobalt levels or an irregular pseudocapsule lining at the initial scan. There was no association with changes in functional scores. Adverse reactions to metal debris in MoM THAs may not be as benign as previous reports have suggested. Close radiological follow-up is recommended, particularly in high-risk groups.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Magnetic Resonance Imaging/methods , Metal-on-Metal Joint Prostheses/adverse effects , Adult , Aged , Aged, 80 and over , Artifacts , Cobalt/blood , Disease Progression , Female , Humans , Longitudinal Studies , Male , Middle Aged
2.
J Bone Joint Surg Br ; 89(3): 393-5, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17356158

ABSTRACT

We describe two cases of fracture of Corin Taper-Fit stems used for cement-in-cement revision of congenital dysplasia of the hip. Both prostheses were implanted in patients in their 50s, with high offsets (+7.5 mm and +3.5 mm), one with a large diameter (48 mm) head and one with a constrained acetabular component. Fracture of the stems took place at nine months and three years post-operatively following low-demand activity. Both fractures occurred at the most medial of the two stem introducer holes in the neck of the prosthesis, a design feature that is unique to the Taper-Fit stem. We would urge caution in the use of these particular stems for cement-in-cement revisions.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Dislocation, Congenital/surgery , Hip Prosthesis , Acetabulum/surgery , Bone Cements , Female , Femur/surgery , Humans , Middle Aged , Prosthesis Failure , Reoperation , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...