Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharmacol Toxicol Methods ; 59(1): 29-34, 2009.
Article in English | MEDLINE | ID: mdl-19028590

ABSTRACT

INTRODUCTION: Drug-induced prolongation of the electrocardiographic QT interval (long QT syndrome) has been associated with increased risk of a serious ventricular arrhythmia, torsade de pointes. Inhibition of hERG, a cardiac potassium channel that controls action potential repolarization, is the most common cause of QT prolongation by non-cardiac drugs. The ICH S7B describes preclinical safety testing required for new drugs, including the determination of the hERG IC(50). Actual and target concentrations may differ due to solubility, stability, or loss of compound. Significant differences will invalidate quantitative concentration-response curves which may be critical to interpretation of drug safety. To examine the frequency and significance of these differences, we conducted an analysis of studies where both the electrophysiology and the dose solution analysis were conducted in-house. We have investigated the actual concentrations of test article in vehicle solution as compared to the target concentrations in an attempt to determine the reasons behind differences between the two values. METHODS: Studies that involved both electrophysiology and dose solution analysis performed at ChanTest Corporation were evaluated. The effects of stability, solubility and loss through the perfusion apparatus on actual dosing concentrations were investigated. RESULTS: There was a large range in the loss of the test article attributed to the perfusion apparatus (range from 0 to 74% loss). For 12 of the 22 studies evaluated, the IC(50) was>2-fold more potent when using actual values as determined by HPLC versus the target concentrations. Twenty-two percent of the test articles were not stable 24 h after room temperature storage; 16% after 24 h frozen conditions. DISCUSSION: The best practices when considering dose solution concentration verification of test article solutions are to: determine the solubility of the compound in a physiological buffer, analyze samples collected from the perfusion chamber, and analyze samples the same day as sample collection (e.g., same day as hERG assay).


Subject(s)
Ether-A-Go-Go Potassium Channels/analysis , Perfusion/instrumentation , Pharmaceutical Preparations/analysis , Buffers , Dimethyl Sulfoxide/chemistry , Electrophysiology/methods , Ethanol/chemistry , Evaluation Studies as Topic , Humans , Pharmaceutical Preparations/chemistry , Pharmaceutical Vehicles/analysis , Pharmaceutical Vehicles/chemistry , Pharmacology/methods , Reference Standards , Solutions/analysis , Solvents/chemistry , Validation Studies as Topic
2.
J Pharmacol Toxicol Methods ; 50(2): 93-101, 2004.
Article in English | MEDLINE | ID: mdl-15385083

ABSTRACT

INTRODUCTION: In vitro evaluation of drug effects on hERG K(+) channels is a valuable tool for identifying potential proarrhythmic side effects in drug safety testing. Patch-clamp recording of hERG K(+) current in mammalian cells can accurately evaluate drug effects, but the methodology has not been standardized, and results vary widely. Our objective was to evaluate two potential sources of variability: the temperature at which recordings are performed and the voltage pulse protocol used to activate hERG K(+) channels expressed in HEK293 cells. METHODS: A panel of 15 drugs that spanned a broad range of potency for hERG inhibition and pharmacological class was evaluated at both room and near-physiological temperatures using several patch-clamp voltage protocols. Concentration-response analysis was performed with three stimulus protocols: 0.5- and 2-s step pulses, or a step-ramp pattern. RESULTS: Block by 2 of the 15 drugs tested, d,l-sotalol (antiarrhythmic) and erythromycin (antibiotic), was markedly temperature sensitive. hERG inhibition measured using a 2-s step-pulse protocol underestimated erythromycin potency compared with results obtained with a step-ramp protocol. Using conservative acceptance criteria and the step-ramp protocol, the IC(50) values for hERG block differed by less than twofold for 15 drugs. DISCUSSION: Data obtained at near-physiological temperatures using a step-ramp pattern are highly repeatable and provide a conservative safety evaluation of hERG inhibition.


Subject(s)
Drug Evaluation, Preclinical/methods , Pharmaceutical Preparations/administration & dosage , Potassium Channel Blockers/pharmacology , Potassium Channels, Voltage-Gated/antagonists & inhibitors , Potassium Channels, Voltage-Gated/drug effects , Cells, Cultured , ERG1 Potassium Channel , Electric Stimulation , Ether-A-Go-Go Potassium Channels , Humans , Inhibitory Concentration 50 , Patch-Clamp Techniques , Reproducibility of Results , Temperature , Transfection
SELECTION OF CITATIONS
SEARCH DETAIL
...