J Clin Ultrasound ; 42(4): 223-6, 2014 May.
Article in English | MEDLINE | ID: mdl-24122949

ABSTRACT

We report a case of a migrated Essure permanent birth control device. The correct diagnosis was made on conventional two-dimensional and three-dimensional pelvic sonography 7 years after placement of the device when the patient presented with persistent right-sided pain. The 3-month post placement hysterosalpingogram had shown an appropriately occluded right fallopian tube but had overlooked the abnormal position of the right Essure device, which was too proximal and extending slightly in the uterine cavity.


Subject(s)
Contraceptive Devices, Female/adverse effects , Fallopian Tubes/diagnostic imaging , Foreign-Body Migration/diagnostic imaging , Adult , Diagnosis, Differential , Fallopian Tubes/surgery , Female , Foreign-Body Migration/complications , Foreign-Body Migration/surgery , Humans , Hysteroscopy/methods , Imaging, Three-Dimensional/methods , Pain/etiology , Ultrasonography