Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Comput Biol Med ; 145: 105438, 2022 06.
Article in English | MEDLINE | ID: mdl-35364309

ABSTRACT

Spinal fusion is a surgical procedure used to join two or more vertebrae to prevent movement between them. This surgical procedure is considered in patients suffering from a wide range of degenerative spinal diseases or vertebral fractures. The success rate of spinal fusion is frequently evaluated subjectively using X-ray computed tomography. The pig was chosen as an animal model for spinal fusion, since its spinal structure is similar to the human spine. Our paper presents an automatic approach for pig's spinal fusion evaluation in 3D. The proposed approach is based on the determination of the vertebral fused area, which reflects the fusion quality. The approach was applied and tested on microCT (µCT) data of fused porcine vertebrae ex-vivo. In our study, three types of implants were used to perform spinal fusion: the iliac crest bone graft used as the gold standard, and two types of novel scaffold implants based on the polymer/ceramic porous foam involving either growth factors or polyphosphates. The evaluation worked automatically for all three types of used implants, and the fusion quality was determined quantitatively. The calculation is based on the detection of the fused area and area of facies intervertebralis, so the percentual representation of the vertebral joint can be determined. Since this approach is versatile and is described in detail as a guide for image processing the data of vertebrae fusion, this methodology has the potential to establish a standard approach for evaluating the fusion quality in ex-vivo samples that can be tested on clinical data.


Subject(s)
Spinal Diseases , Spinal Fusion , Animals , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Lumbosacral Region , Swine , X-Ray Microtomography , X-Rays
2.
Materials (Basel) ; 15(3)2022 Jan 30.
Article in English | MEDLINE | ID: mdl-35161043

ABSTRACT

We report a reproducible preparation and characterization of highly homogeneous thermoplastic starch/pol(ε-caprolactone) blends (TPS/PCL) with a minimal thermomechanical degradation and co-continuous morphology. These materials would be suitable for biomedical applications, specifically for the local release of antibiotics (ATB) from the TPS phase. The TPS/PCL blends were prepared in the whole concentration range. In agreement with theoretical predictions based on component viscosities, the co-continuous morphology was found for TPS/PCL blends with a composition of 70/30 wt.%. The minimal thermomechanical degradation of the blends was achieved by an optimization of the processing conditions and by keeping processing temperatures as low as possible, because higher temperatures might damage ATB in the final application. The blends' homogeneity was verified by scanning electron microscopy. The co-continuous morphology was confirmed by submicron-computed tomography. The mechanical performance of the blends was characterized in both microscale (by an instrumented microindentation hardness testing; MHI) and macroscale (by dynamic thermomechanical analysis; DMTA). The elastic moduli of TPS increased ca four times in the TPS/PCL (70/30) blend. The correlations between elastic moduli measured by MHI and DMTA were very strong, which implied that, in the future studies, it would be possible to use just micromechanical testing that does not require large specimens.

3.
Front Vet Sci ; 8: 759093, 2021.
Article in English | MEDLINE | ID: mdl-34957278

ABSTRACT

Adverse effects of high dietary phosphorus on bone health have been observed in both animal and human studies. The aim of the investigation was to examine chronic effects of high phosphorus diet on the apical mandibular cortical thickness and volume in a hystricomorph rodent (Octodon degus) using microcomputed tomography. Male degus were randomly divided into two groups fed by different mineral contents from the age of 12 weeks till the age of 17 months. The micro-CT scanning and wall thickness analysis were applied on the region of the mandible exactly under the apices of the 4th premolar tooth, first molar tooth, and second molar tooth in two animals from each group. General overview and mapping of the ventral mandibular bone thickness revealed pronounced bony mandibular protrusions in all the animals fed a high-phosphorus diet with obvious bone thinning apically to the 4th premolar and first and second molar tooth apices. Mandibular bone volume and thickness located apically to the premolar and molars were statistically significantly smaller/thinner in the group fed by a high phosphorus diet. The thinnest bone measured 0.004 mm, where the mandibular 4th premolar tooth almost perforated the mandibular cortex. Similar studies of metabolic bone disease and its influence on alveolar bone were also published in rats and mice. The influence of different environmental, infectious, or metabolic factors on the growing tooth, alveolar bone formation, and bone pathologies must be done experimentally on growing animals. In contrast, degus have continuously growing dentition, and the effect of any of the above listed factors can be studied in this animal model at any age and for longer time periods.

4.
Biomedicines ; 9(7)2021 Jun 25.
Article in English | MEDLINE | ID: mdl-34202232

ABSTRACT

Many growth factors have been studied as additives accelerating lumbar fusion rates in different animal models. However, their low hydrolytic and thermal stability both in vitro and in vivo limits their workability and use. In the proposed work, a stabilized vasculogenic and prohealing fibroblast growth factor-2 (FGF2-STAB®) exhibiting a functional half-life in vitro at 37 °C more than 20 days was applied for lumbar fusion in combination with a bioresorbable scaffold on porcine models. An experimental animal study was designed to investigate the intervertebral fusion efficiency and safety of a bioresorbable ceramic/biopolymer hybrid implant enriched with FGF2-STAB® in comparison with a tricortical bone autograft used as a gold standard. Twenty-four experimental pigs underwent L2/3 discectomy with implantation of either the tricortical iliac crest bone autograft or the bioresorbable hybrid implant (BHI) followed by lateral intervertebral fixation. The quality of spinal fusion was assessed by micro-computed tomography (micro-CT), biomechanical testing, and histological examination at both 8 and 16 weeks after the surgery. While 8 weeks after implantation, micro-CT analysis demonstrated similar fusion quality in both groups, in contrast, spines with BHI involving inorganic hydroxyapatite and tricalcium phosphate along with organic collagen, oxidized cellulose, and FGF2- STAB® showed a significant increase in a fusion quality in comparison to the autograft group 16 weeks post-surgery (p = 0.023). Biomechanical testing revealed significantly higher stiffness of spines treated with the bioresorbable hybrid implant group compared to the autograft group (p < 0.05). Whilst histomorphological evaluation showed significant progression of new bone formation in the BHI group besides non-union and fibrocartilage tissue formed in the autograft group. Significant osteoinductive effects of BHI based on bioceramics, collagen, oxidized cellulose, and FGF2-STAB® could improve outcomes in spinal fusion surgery and bone tissue regeneration.

5.
Elife ; 102021 02 26.
Article in English | MEDLINE | ID: mdl-33635272

ABSTRACT

Organ function depends on tissues adopting the correct architecture. However, insights into organ architecture are currently hampered by an absence of standardized quantitative 3D analysis. We aimed to develop a robust technology to visualize, digitalize, and segment the architecture of two tubular systems in 3D: double resin casting micro computed tomography (DUCT). As proof of principle, we applied DUCT to a mouse model for Alagille syndrome (Jag1Ndr/Ndr mice), characterized by intrahepatic bile duct paucity, that can spontaneously generate a biliary system in adulthood. DUCT identified increased central biliary branching and peripheral bile duct tortuosity as two compensatory processes occurring in distinct regions of Jag1Ndr/Ndr liver, leading to full reconstitution of wild-type biliary volume and phenotypic recovery. DUCT is thus a powerful new technology for 3D analysis, which can reveal novel phenotypes and provide a standardized method of defining liver architecture in mouse models.


Many essential parts of the body contain tubes: the liver for example, contains bile ducts and blood vessels. These tubes develop right next to each other, like entwined trees. To do their jobs, these ducts must communicate and collaborate, but they do not always grow properly. For example, babies with Alagille syndrome are born with few or no bile ducts, resulting in serious liver disease. Understanding the architecture of the tubes in their livers could explain why some children with this syndrome improve with time, but many others need a liver transplant. Visualising biological tubes in three dimensions is challenging. One major roadblock is the difficulty in seeing several tubular structures at once. Traditional microscopic imaging of anatomy is in two dimensions, using slices of tissue. This approach shows the cross-sections of tubes, but not how the ducts connect and interact. An alternative is to use micro computed tomography scans, which use X-rays to examine structures in three dimensions. The challenge with this approach is that soft tissues, which tubes in the body are made of, do not show up well on X-ray. One way to solve this is to fill the ducts with X-ray absorbing resins, making a cast of the entire tree structure. The question is, can two closely connected tree structures be distinguished if they are cast at the same time? To address this question, Hankeova, Salplachta et al. developed a technique called double resin casting micro computed tomography, or DUCT for short. The approach involved making casts of tube systems using two types of resin that show up differently under X-rays. The new technique was tested on a mouse model of Alagille syndrome. One resin was injected into the bile ducts, and another into the blood vessels. This allowed Hankeova, Salplachta et al. to reconstruction both trees digitally, revealing their length, volume, branching, and interactions. In healthy mice, the bile ducts were straight with uniform branches, but in mice with Alagille syndrome ducts were wiggly, and had extra branches in the centre of the liver. This new imaging technique could improve the understanding of tube systems in animal models of diseases, both in the liver and in other organs with tubes, such as the lungs or the kidneys. Hankeova, Salplachta et al. also lay a foundation for a deeper understanding of bile duct recovery in Alagille syndrome. In the future, DUCT could help researchers to see how mouse bile ducts change in response to experimental therapies.


Subject(s)
Alagille Syndrome/physiopathology , Bile Ducts/physiopathology , X-Ray Microtomography/methods , Animals , Bile Ducts/growth & development , Disease Models, Animal , Mice , Mice, Transgenic , X-Ray Microtomography/classification
6.
Sensors (Basel) ; 21(1)2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33401506

ABSTRACT

In this article, we introduce a new ring artifacts reduction procedure that combines several ideas from existing methods into one complex and robust approach with a goal to overcome their individual weaknesses and limitations. The procedure differentiates two types of ring artifacts according to their cause and character in computed tomography (CT) data. Each type is then addressed separately in the sinogram domain. The novel iterative schemes based on relative total variations (RTV) were integrated to detect the artifacts. The correction process uses the image inpainting, and the intensity deviations smoothing method. The procedure was implemented in scope of lab-based X-ray nano CT with detection systems based on charge-coupled device (CCD) and scientific complementary metal-oxide-semiconductor (sCMOS) technologies. The procedure was then further tested and optimized on the simulated data and the real CT data of selected samples with different compositions. The performance of the procedure was quantitatively evaluated in terms of the artifacts' detection accuracy, the comparison with existing methods, and the ability to preserve spatial resolution. The results show a high efficiency of ring removal and the preservation of the original sample's structure.


Subject(s)
Artifacts , Image Processing, Computer-Assisted , Algorithms , Phantoms, Imaging , Tomography, X-Ray Computed , X-Rays
7.
Biomed Eng Lett ; 10(4): 603-617, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33194251

ABSTRACT

Bone presents different systemic functionalities as calcium phosphate reservoir, organ protection, among others. For that reason, the bone health conditions are essential to keep in equilibrium the metabolism of several body systems. Different technologies exist to diagnose bone conditions with invasive methods based on ionizing radiation. Therefore, there is a challenge to develop new ways to evaluate bone alterations in a noninvasive form. This study shows the assessment of a piezo-actuated device acting on a human tooth for the bio-monitoring of bone alterations. The bone diagnosis is performed by applying the electromechanical impedance technique (EMI), commonly used in structural health monitoring. For the experimental tests, five bone samples were prepared, and one was chosen as the monitoring. All samples were put in a decalcifying substance (TBD1 acid-base) at different times to emulate localized bone mineral alterations. Bone reductions were computed by using X-ray micro-computed tomography analyzing the morphometry. Electrical resistance measurements (piezo-device) were taken for the monitoring specimen meanwhile it was partially decalcified during 8520 seconds. In the frequency spectrum, several observation windows showed that the bone alterations gradually changed the electrical resistance signals which were quantified statistically. Results evidenced that the bone density changes are correlated with the electrical resistance measurements; these changes presented an exponential behavior as much as in the calculated index, and bone mineral reduction. The results demonstrated that bone alterations exhibit linear dependence with the computed statistical indexes. This result confirms that it is possible to observe the bone changes from the teeth as a future application.

9.
J Aerosol Sci ; 150: 105649, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32904428

ABSTRACT

The inhalation route has a substantial influence on the fate of inhaled particles. An outbreak of infectious diseases such as COVID-19, influenza or tuberculosis depends on the site of deposition of the inhaled pathogens. But the knowledge of respiratory deposition is important also for occupational safety or targeted delivery of inhaled pharmaceuticals. Simulations utilizing computational fluid dynamics are becoming available to a wide spectrum of users and they can undoubtedly bring detailed predictions of regional deposition of particles. However, if those simulations are to be trusted, they must be validated by experimental data. This article presents simulations and experiments performed on a geometry of airways which is available to other users and thus those results can be used for intercomparison between different research groups. In particular, three hypotheses were tested. First: Oral breathing and combined breathing are equivalent in terms of particle deposition in TB airways, as the pressure resistance of the nasal cavity is so high that the inhaled aerosol flows mostly through the oral cavity in both cases. Second: The influence of the inhalation route (nasal, oral or combined) on the regional distribution of the deposited particles downstream of the trachea is negligible. Third: Simulations can accurately and credibly predict deposition hotspots. The maximum spatial resolution of predicted deposition achievable by current methods was searched for. The simulations were performed using large-eddy simulation, the flow measurements were done by laser Doppler anemometry and the deposition has been measured by positron emission tomography in a realistic replica of human airways. Limitations and sources of uncertainties of the experimental methods were identified. The results confirmed that the high-pressure resistance of the nasal cavity leads to practically identical velocity profiles, even above the glottis for the mouth, and combined mouth and nose breathing. The distribution of deposited particles downstream of the trachea was not influenced by the inhalation route. The carina of the first bifurcation was not among the main deposition hotspots regardless of the inhalation route or flow rate. On the other hand, the deposition hotspots were identified by both CFD and experiments in the second bifurcation in both lungs, and to a lesser extent also in both the third bifurcations in the left lung.

10.
Forensic Sci Int ; 291: 260-271, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30268052

ABSTRACT

We evaluated the degradation of cortical bone tissue by hydrochloric acid (HCl) since intentional bone decalcification in a forensic context has not been studied on a histomorphological level. We used 70 pig metatarsal bones split into subsamples and immersed in one of three concentrations of acidic solutions (0.5M, 1M, 2M HCl) for two and four hours. We analyzed the cortical thicknesses on transversal cross-sections, thicknesses of the three histomorphologically distinct zones present in acid-immersed bones, and number and area of crystals present in one of the zones. Furthermore, we analyzed the ratio of calcium to phosphorus (Ca:P). We observed a division of the cortical bone cross section into three distinctive zones: demineralized matrix (DM) in the periosteal part of bone, middle contact zone (CZ), and mineralized matrix (MM) in the endosteal part of bone. With increasing acid concentration and time of immersion (from 0.5M HCl for 2h to 2M HCl for 4h), the thickness of DM increased by 67%, the thickness of CZ increased by 56%, and the thickness of MM decreased by 32%. The Ca:P ratio in the contact zone of acid-treated samples did not change significantly with changing acid concentration and time of immersion. The Ca:P ratio of the CZ decreased by 10% when compared to the Ca:P ratio of MM in acid-treated samples. Moreover, we observed crystals on the outer periosteal border of the DM zone, in the CZ, and in the MM Haversian/Volkmann's canals. The size and number of the crystals in the CZ of acid-treated bones increased with acid concentration and time of acid immersion. Moreover, we also observed significant differences in all analyzed properties between anatomical regions. Due to varying reactions to acid immersion among anatomical regions, bone micro-degradation should be observed separately for each region.


Subject(s)
Cortical Bone/ultrastructure , Hydrochloric Acid/toxicity , Metatarsal Bones/ultrastructure , Animals , Calcium/metabolism , Cortical Bone/diagnostic imaging , Cortical Bone/metabolism , Forensic Pathology , Metatarsal Bones/diagnostic imaging , Metatarsal Bones/metabolism , Microscopy, Electron, Scanning , Periosteum/diagnostic imaging , Periosteum/ultrastructure , Phosphorus/metabolism , Spectrometry, X-Ray Emission , Sus scrofa , X-Ray Microtomography
SELECTION OF CITATIONS
SEARCH DETAIL
...