Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Neurochir (Wien) ; 166(1): 209, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38727725

ABSTRACT

Based on a personal experience of 4200 surgeries, radiofrequency thermocoagulation is useful lesional treatment for those trigeminal neuralgias (TNs) not amenable to microvascular decompression (idiopathic or secondary TNs). Introduced through the foramen ovale, behind the trigemnial ganglion in the triangular plexus, the needle is navigated by radiology and neurophysiological testing to target the retrogasserian fibers corresponding to the trigger zone. Heating to 55-75 °C can achieve hypoesthesia without anaesthesia dolorosa if properly controlled. Depth of anaesthesia varies dynamically sedation for cannulation and lesioning, and awareness during neurophysiologic navigation. Proper technique ensures long-lasting results in more than 75% of patients.


Subject(s)
Electrocoagulation , Trigeminal Neuralgia , Trigeminal Neuralgia/surgery , Trigeminal Neuralgia/diagnostic imaging , Humans , Electrocoagulation/methods , Trigeminal Nerve/surgery , Foramen Ovale/surgery , Foramen Ovale/diagnostic imaging , Trigeminal Ganglion/surgery , Microvascular Decompression Surgery/methods , Treatment Outcome
2.
Rev Neurol (Paris) ; 177(3): 283-289, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32305140

ABSTRACT

BACKGROUND: Little is known about outcome and settings adaptations after replacement of constant-voltage non-rechargeable implantable pulse generator (CV-nrIPG) by constant-current rechargeable IPG (CC-rIPG). OBJECTIVE: To determine the feasibility and safety of replacing a CV-nrIPG by a CC-rIPG in Parkinson's disease (PD) and the subsequent outcome. METHODS: A prospective cohort of thirty PD patients, whose CV-nrIPG was replaced by a CC-rIPG in University Hospital of Lyon between January 2017 and December 2018 (rIPG group) and 39 PD patients, who underwent the replacement of a CV-nrIPG by the same device in 2016 (nrIPG group), were enrolled in this study. Three surgeons performed the operations. Duration of hospitalization for the replacement as well as the number of in or outpatient visits during the first 3 months after the surgery were recorded. In the rIPG group, we compared preoperative DBS settings and the theoretical amplitude estimated using Ohm's law to the amplitude used at the end of follow-up. We assessed patients' and clinicians' opinion on the patient global functioning after the replacement using Clinical Global Impression score. RESULTS: Duration of hospitalization (P=0.47) and need for additional hospitalizations (P=0.73) or consultations (P=0.71) to adapt DBS parameters did not differ between the two groups. Neurological condition (CGI score) was considered as unchanged by both patients and neurologists. Final amplitude of stimulation using CC-rIPG was not predicted by Ohm's law in most cases. CONCLUSIONS: Replacing CV-nrIPG by CC-rIPG is safe and well tolerated but require neurological expertise to set the new parameters of stimulation.


Subject(s)
Parkinson Disease , Deep Brain Stimulation , Electrodes, Implanted , Feasibility Studies , Humans , Parkinson Disease/therapy , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...