Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
J Clin Med ; 13(12)2024 Jun 09.
Article in English | MEDLINE | ID: mdl-38929914

ABSTRACT

Background: The treatment choice of visceral artery aneurysms in an elective setting is debated. The durability and the risk of reintervention with endovascular treatment are still reasons for concern, whereas open surgery is invasive and burdened by major complications. In anecdotal reports and isolated studies, robotic-assisted surgery seems to provide the possibility of a minimally invasive treatment and the durability of traditional open surgery, but the literature supporting this view is scarce. This review aims to collect the results of robotic-assisted surgery in the treatment of visceral artery aneurysms. Methods: A systematic search of the main research databases was performed: the study endpoints were mortality and conversion rates, perioperative morbidity, and freedom from late complications and reinterventions. Results: We identified 16 studies on 53 patients. All cases underwent successful resection, with three conversions to laparoscopy. Perioperative and aneurysm-related mortality were nil. Over a median follow-up of 9 months, two reinterventions were reported (3.6%). Conclusion: The robotic technique is safe and effective in treating splenic and renal artery aneurysms, and it should be considered as a valuable alternative to endovascular and open repair, although larger sample sizes and a longer-term follow-up are necessary to confirm such results.

2.
Asian Cardiovasc Thorac Ann ; 32(4): 227-230, 2024 May.
Article in English | MEDLINE | ID: mdl-38751049

ABSTRACT

PURPOSE: To describe our clinical experience of endovascular exclusion of popliteal artery aneurysms using the new self-expandable covered stent SOLARIS® (Scitech Medical, Brazil), and to report its results in the context of surgical and endovascular treatment of popliteal artery aneurysms. CASE REPORT: Among 20 popliteal artery aneurysms undergoing open or endovascular repair in 2022 and 2023, two patients were successfully treated with the Solaris stentgraft. Both patients had a patent popliteal artery and three run-off vessels. After stentgraft implantation, they received dual antiplatelet therapy for three months and they were followed-up with Duplex scan and clinical evaluation after three months, and every six months thereafter. After three months, one Solaris stentgraft had complete thrombosis and the other ruptured, requiring surgical removal. No complications were observed among the other aneurysms treated with open repair or with the Viabahn® stentgraft. CONCLUSIONS: Endovascular treatment of popliteal aneurysms with the new covered self-expandable stent Solaris resulted in severe complications in the two cases reported, and in worse short-term outcomes than endovascular repair with Viabahn® and open repair. Its off-label use to treat popliteal artery aneurysms should be therefore discouraged.


Subject(s)
Aneurysm , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Popliteal Artery , Prosthesis Design , Stents , Humans , Popliteal Artery/diagnostic imaging , Popliteal Artery/surgery , Popliteal Artery/physiopathology , Aneurysm/surgery , Aneurysm/diagnostic imaging , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Male , Aged , Vascular Patency , Platelet Aggregation Inhibitors/therapeutic use , Female , Time Factors , Middle Aged , Dual Anti-Platelet Therapy , Computed Tomography Angiography , Popliteal Artery Aneurysm
3.
J Clin Med ; 12(18)2023 Sep 20.
Article in English | MEDLINE | ID: mdl-37763025

ABSTRACT

BACKGROUND: Ruptured splenic artery aneurysms (r-SAA), although rare, are burdened by high morbidity and mortality, even despite emergent surgical repair. It is suggested that endovascular treatment can achieve reduction in peri-operative death and complication rates, as in other vascular diseases, but evidence of such benefits is still lacking in this particular setting. We report a case of an r-SAA treated by trans-arterial embolization and then converted to open surgery for persistent bleeding, and we provide a systematic review of current results of open and endovascular repair of r-SAAs. MATERIALS AND METHODS: A 50-year-old male presenting in shock for a giant r-SAA underwent emergent coil embolization and recovered hemodynamic stability. On the following day, he underwent laparotomy for evacuation of the huge intraperitoneal hematoma, but residual bleeding was noted from the splenic artery, which was ligated after coil removal, and a splenectomy was performed. A systematic literature review of the reported mortality and complications of r-SAA undergoing open (OSR) or endovascular (EVT) treatment was performed using the main search databases. All primary examples of research published since 1990 were included regardless of sample size. The main outcome measures were mortality and reinterventions. Secondary outcomes were post-operative complications. RESULTS: We selected 129 studies reporting on 350 patients-185 treated with OSR and 165 with EVT. Hemodynamically unstable patients and ruptures during pregnancy were more frequently treated with open repair. Overall, there were 37 deaths (mortality: 10.6%)-24 in the OSR group and 13 in the EVTr group (mortality: 12.9% and 7.8% respectively, p-value: 0.84). There were 37 reinterventions after failed or complicated endovascular repair -6 treated with endovascular re-embolization and 31 with laparotomy and splenectomy (22.4%); there were 3 (1.6%) reinterventions after open repair. Overall complication rates were 7.3% in the EVT group (n: 12) and 4.2% in the OSR group (n: 7), and did not require reintervention. No significant differences in overall complications or in any specific complication rate were observed between the two groups. CONCLUSIONS: Current results of r-SAA treatment show equipoise terms of morbidity and mortality between open and endovascular repair; however, in case of hemodynamic instability and rupture during pregnancy, open surgery might still be safer. Moreover, endovascular repair is still burdened by a significantly higher rate of reinterventions, mostly with conversions to open surgery.

5.
J Endovasc Ther ; : 15266028231170161, 2023 Apr 28.
Article in English | MEDLINE | ID: mdl-37118936

ABSTRACT

PURPOSE: Newer generation abdominal endografts, including Treo (Terumo Aortic, Sunrise, Florida), have shown optimal safety and effectiveness in treating abdominal aortic aneurysms (AAAs), even with hostile anatomy over the short- and mid-term. The durability of such results, however, is still a controversial issue, due to the paucity of long-term data. Our aim is to show the long-term outcomes of endovascular aortic repair of both standard and hostile AAAs with the Treo endograft on a cohort of patients treated between 2016 and 2017. METHODS: We analyzed the postoperative follow-up of 37 consecutive patients who have undergone endovascular aortic repair (EVAR) with the Treo Endograft between 2016 and 2017, whose baseline clinical conditions, operative data, and short-term outcomes had been published in 2018. All patients were followed up by computed tomography angiography (CTA) at 6 and 12 months and 5 years postoperatively. Primary endpoints were aortic-related mortality, type I-III endoleak (EL), and reintervention rate. Secondary endpoints were the rates of type II ELs and aneurysm sac regression. RESULTS: Of 37 patients, 27 had at least one criterion of anatomic hostility and 11 were performed outside the device-specific instructions for use (IFU). In the perioperative period, we observed 100% technical success, with no perioperative mortality. Over a mean follow-up of 5.5 years (66 months), 3 patients (8.1%) were lost to follow-up and 3 (8.1%) died of non-aortic causes (overall survival: 91.9%). One type IA EL of an AAA with a hostile neck (but within the IFU) and a type III EL of an AAA with standard anatomy were observed and treated by endovascular relining (overall reintervention rate: 5.5%). Four type II ELs were associated with aneurysm sac stability over time and are still under surveillance. Mean aneurysm shrinkage was 11.25±8.30 mm. CONCLUSION: The optimal results of the Treo Endograft in terms of complication and reintervention rates reported over the mid-term by the current literature (ITA-ENDOBOOT registry) are maintained on the long term, both in case of hostile and friendly aortic anatomy, with a satisfactory shrinkage rate of the aneurysm sac. CLINICAL IMPACT: The innovative characteristics of Treo and its short-term results are well-known and reported. The present case series contributes to the scientific validation of a new-generation abdominal aortic endograft over the long-term, focusing especially on its performance in treating AAAs with hostile anatomy. Its 5-years outcomes confirm the optimal results already reported over the short- and mid-term.

6.
ACS Sens ; 8(3): 1017-1032, 2023 03 24.
Article in English | MEDLINE | ID: mdl-36912628

ABSTRACT

Peripheral intravenous catheters are administered for various purposes, such as blood sampling or the infusion of contrast agents and drugs. Extravasation happens when the catheter is unintentionally directed outside of the vein due to movement of the intravascular catheter, enhanced vascular permeability, or occlusion of the upstream vein. In this article, extravasation and its mechanism are discussed. Subsequently, the sensorized devices (e.g., single sensor and multimodal detection) to identify the extravasation phenomena are highlighted. In this review article, we have shed light on both physiological and engineering points of view of extravasation and its detection approaches. This review provides an overview on the most recent and relevant technologies that can help in the early detection of extravasation.


Subject(s)
Catheterization, Peripheral , Contrast Media , Engineering
8.
Ann Vasc Surg ; 86: 111-116, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35717007

ABSTRACT

BACKGROUND: This study aims to propose a minimally invasive surgical approach to the common femoral artery in endovascular aortic repair and assess its value by a single-center retrospective study including 118 patients. METHODS: Between 2017 and 2022, all patients receiving endovascular treatment for thoracic and abdominal aortic aneurysms in our center had the anterior wall of the common femoral artery exposed, through a 2-3 cm transverse groin incision, instead of a complete surgical cutdown. We access the artery with a purse-string suture, held tight with a tourniquet. After procedure completion, we tie the purse-string closing the arteriotomy. We retrospectively analyzed the cohort of all consecutive patients treated with endovascular aortic repair in this period and recorded primary and assisted technical success, operative time, in-hospital length of stay, access failure, and access-related complications, comparing the results with the current literature. RESULTS: All procedures were successful, with no perioperative mortality. Primary technical success was achieved in 116 patients; 2 required adjunctive procedures. No access failure or access-related complications (thrombosis, groin hematoma, lymphocele, wound dehiscence, or infection) occurred. Two accesses required conversion to complete femoral artery exposure and endarterectomy. Operatory time and length of in-hospital stay were comparable to the outcomes of the major studies reporting on percutaneous access, saving the costs of the closure devices. CONCLUSIONS: Minimally invasive surgical access is safe and feasible for endovascular aortic procedures. Compared to the costs of percutaneous access found in literature, it is cost-effective. It can be chosen whenever the percutaneous approach is not feasible or at a high risk of complications.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Retrospective Studies , Treatment Outcome , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/etiology , Femoral Artery/diagnostic imaging , Femoral Artery/surgery
9.
Acta Biomed ; 93(S1): e2022181, 2022 06 29.
Article in English | MEDLINE | ID: mdl-35765914

ABSTRACT

BACKGROUND AND AIM: Spinal cord ischemia following open or endovascular aneurysm repair of the abdominal aorta is rare but highly disabling complication. The aim of this work is to report on its occurrence and its legal consequences. METHODS: We report a case of spinal cord ischemia complicating an endovascular aortic repair, its management and sequalae, comparing it with the existing literature and we examine its legal consequences resulting in a malpractice lawsuit and the final decision of the judge. RESULTS: Although the causal relation between SCI and the neurological deficits reported were assessed by the Court, no element of responsibility imputable to the Hospital or the Medical Staff were found, since the defendant had made every effort to prevent it in the preoperatory setting, and to treat it once it established in the post-operative phase. CONCLUSIONS: predictable but unpreventable complications of necessary interventions rule out medical malpractice, as long as the patient is fully informed about the risks and benefits of the treatment, and provided that in the perioperative setting all due measures are taken in order to prevent it and treat it.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/methods , Humans , Spinal Cord Ischemia/etiology , Spinal Cord Ischemia/prevention & control , Spinal Cord Ischemia/surgery
11.
Lab Anim ; 55(5): 472-477, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33884898

ABSTRACT

Breast cancer is the most common cancer among women worldwide. For high-risk women, contrast enhanced (CE)-magnetic resonance imaging (MRI) is recommended as supplemental screening together with mammography. The development of new MRI contrast agents is an active field of research, which requires efficacy tests on appropriate preclinical pathological models. In this work, a refined method to orthotopically induce breast cancer in BALB/c mice was developed using ultrasound (US) as a guide for the precise localisation of the tumour induction site and to improve animal welfare. The method was coupled with CE-MRI to characterise the evolution of the tumoural lesion.


Subject(s)
Mammography , Neoplasms , Animals , Contrast Media , Disease Models, Animal , Mice , Mice, Inbred BALB C , Ultrasonography, Interventional
12.
Oncotarget ; 11(24): 2310-2326, 2020 Jun 16.
Article in English | MEDLINE | ID: mdl-32595830

ABSTRACT

Tumor-targeting contrast agents may facilitate resection of solid neoplasms during fluorescence-guided surgery. Preliminary safety and imaging efficacy of the near-infrared fluorescent probe DA364 were evaluated during surgical resection of spontaneous solid tumors in 24 dogs. Intra-operative imaging was performed in situ and on excised specimens to evaluate fluorescence intensities of tumor and adjacent tissues. After standard-of-care tumor resection, the wound bed was imaged again, and additional tissue was excised if residual fluorescence was detected. DA364 was well tolerated after intravenous administration. The median tumor-to-background ratio in situ for mammary tumors, mast cell tumors and sarcomas was 1.8 (range 1.2-3.9), 2.2 (range 1.0-5.6), and 4.2 (range 2.0-4.3), respectively. Qualitative intra-operative tumor identification was feasible in half of the cases. Remaining fluorescence was detected in four wound beds that contained residual disease, and in11 tumor-free wound beds, confirmed by histopathology. Overall, DA364 did not raise safety concerns and showed accumulation in different types of spontaneous tumors, showing potential to pinpoint residual disease. Larger clinical trials are necessary to select accurate dosing and imaging protocols for specific indications to evaluate the sensitivity and specificity of the agent.

13.
Vet Rec ; 187(7): 273, 2020 Oct 03.
Article in English | MEDLINE | ID: mdl-32345608

ABSTRACT

BACKGROUND: Near-infrared fluorescence (NIRF) imaging is a relatively novel technique that can aid surgeons during intraoperative tumour identification. METHODS: Nine canine oncology patients (five mammary gland tumours, three mast cell tumours and one melanoma) received intravenous indocyanine green (ICG). After 24 hours, tumours were resected and fluorescence intensities of tumours and surroundings were evaluated. Additional wound bed tissue was resected if residual fluorescence was present after tumour resection. Ex vivo, fluorescence-guided dissection was performed to separate tumour from surrounding tissue. RESULTS: Intraoperative NIRF-guided tumour delineation was feasible in four out of nine dogs. Wound bed imaging after tumour removal identified nine additional fluorescent lesions, of which four contained tumour tissue. One of these four true positive in vivo lesions was missed by standard-of-care inspection. Ex vivo fluorescence-guided tumour dissection showed a sensitivity of 72 per cent and a specificity of 80 per cent in discriminating between tumour and surrounding tissue. CONCLUSION: The value of ICG for intraoperative tumour delineation seems more limited than originally thought. Although NIRF imaging using ICG did identify remaining tumour tissue in the wound bed, a high false positive rate was also observed.


Subject(s)
Dog Diseases/surgery , Indocyanine Green , Neoplasms/veterinary , Surgery, Computer-Assisted/veterinary , Animals , Dogs , Female , Fluorescence , Male , Neoplasms/surgery , Surgery, Computer-Assisted/methods
14.
Animal Model Exp Med ; 2(1): 58-63, 2019 Mar.
Article in English | MEDLINE | ID: mdl-31016288

ABSTRACT

Meningioma in vivo research is hampered by the difficulty of establishing an easy and reproducible orthotopic model able to mimic the characteristics of a human meningioma. Moreover, leptomeningeal dissemination and high mortality are often associated with such orthotopical models, making them useless for clinical translation studies. An optimized method for inducing meningiomas in nude mice at two different sites is described in this paper and the high reproducibility and low mortality of the models are demonstrated. Skull base meningiomas were induced in the auditory meatus and convexity meningiomas were induced on the brain surface of 23 and 24 nude mice, respectively. Both models led to the development of a mass easily observable by imaging methods. Dynamic contrast enhanced MRI was used as a tool to monitor and characterize the pathology onset and progression. At the end of the study, histology was performed to confirm the neoplastic origin of the diseased mass.

15.
J Biophotonics ; 12(3): e201800217, 2019 03.
Article in English | MEDLINE | ID: mdl-30350407

ABSTRACT

The recent discovery of fluorescent dyes for improving pathologic tissues identification has highlighted the need of robust methods for performance validation especially in the field of fluorescence-guided surgery. Optical imaging of excised tissue samples is the reference tool to validate the association between dyes localization and the underlying histology in a controlled environment. Spectral unmixing may improve the validation process discriminating dye from endogenous signal. Here, an innovative spectral modeling approach that weights the spectral shifts associated with changes in chemical environment is described. The method is robust against spectral shift variations and its application leads to unbiased spectral weights estimates as demonstrated by numerical simulations. Finally, spectral shifts values computed pixel-wise from spectral images are used to display additional information with potential diagnostic value.


Subject(s)
Models, Theoretical , Optical Imaging , Carbocyanines/chemistry , Fluorescent Dyes/chemistry , Peptides, Cyclic/chemistry
16.
Ann Vasc Surg ; 47: 282.e7-282.e11, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28947215

ABSTRACT

BACKGROUND: Aortic rupture in Behcet's disease is associated with high mortality rates. Endovascular approach with parallel graft technique can be a valid solution in emergency setting for the treatment of thoraco-abdominal aorta involvement in Behcet's disease. METHODS: We describe the clinical case of a 41-year-old man, urgently hospitalized for a rupture of thoraco-abdominal aorta with occlusion of the celiac trunk and involvement of superior mesenteric artery. The patient also presented a massive right hemothorax and a massive left pulmonary thromboembolism. An aortic endoprosthesis was deployed from the third bottom of the thoracic aorta to the origin of the renal arteries. Parallel stent-graft technique was used to preserve the patency of the superior mesenteric artery. The procedure was performed with local anaesthesia due to the critical conditions of the patient. The patient was discharged in good clinical conditions. RESULTS: The angio-computed tomography performed 6 months after surgery showed good deployment of the endoprosthesis and patency of the superior mesenteric artery. CONCLUSION: In high risk for surgery patients, endovascular treatment with parallel stent graft of thoraco-abdominal aorta rupture is safe and feasible.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Rupture/surgery , Behcet Syndrome/complications , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Adult , Anesthesia, Local , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/etiology , Aortic Rupture/diagnostic imaging , Aortic Rupture/etiology , Aortography/methods , Behcet Syndrome/diagnosis , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Computed Tomography Angiography , Emergencies , Endovascular Procedures/instrumentation , Humans , Male , Pulmonary Embolism/etiology , Stents , Treatment Outcome
17.
Nanomedicine ; 13(2): 693-700, 2017 02.
Article in English | MEDLINE | ID: mdl-27720928

ABSTRACT

The current study was performed to evaluate the in vivo efficiency of a new nano-sized contrast agent called paramagnetic Solid Lipid Nanoparticles, pSLNs, having promising relaxivity properties for Magnetic Resonance Imaging application. Good stability and stealth properties toward macrophage uptake have been demonstrated. An in vivo MRI study resulted in an improved signal enhancement in the tumor tissue particularly when folate as targeting ligand was used to decorate the nanoparticles surface. Afterward, the biodistribution of pSLNs in several organs was investigated. The accumulation of pSLNs in kidneys, femoral bones, spleen and brain was quite low while high tropism of pSLNs was found for the liver. In this regard, approaches to improve the rate of the hepatic clearance have been proposed.


Subject(s)
Lipids , Magnetic Resonance Imaging , Nanoparticles , Cell Line, Tumor , Humans , Tissue Distribution
18.
Chemistry ; 19(34): 11189-93, 2013 Aug 19.
Article in English | MEDLINE | ID: mdl-23843364

ABSTRACT

Highly efficient magnetic resonance imaging (MRI) probes have been prepared by loading Gd(III) complexes on the surface of solid lipid nanoparticles (pSLNs). Applicability as molecular imaging probes is demonstrated by an in vitro model study with targeted pSLNs.


Subject(s)
Lipids/chemistry , Molecular Probes/chemistry , Nanoparticles/chemistry , Cell Line, Tumor , Coordination Complexes/chemistry , Gadolinium/chemistry , Humans , Magnetic Resonance Imaging , Magnetics , Microscopy, Confocal
19.
Contrast Media Mol Imaging ; 8(4): 350-60, 2013.
Article in English | MEDLINE | ID: mdl-23613438

ABSTRACT

Despite spontaneous tumor growth in genetically engineered mice being one of the most recognized tools for the in vivo evaluation of novel diagnostic and therapeutic anticancer compounds, monitoring early stage lesions in live animals is a goal that has yet to be achieved. A large number of targets for the molecular imaging of various diseases have been identified and many imaging technologies, including optical techniques are emerging. One of the most commonly exploited targets in tumor imaging is αv ß3 integrin, which plays an important role in the expansion, invasiveness and metastatic capability of a number of cancers, including breast cancer. The aim of this study was to set up an optical imaging method for the early detection of autochthonous mammary cancer in female BALB/c mice transgenic for the rat-ErbB-2 oncogene (BALB-neuT). We show that DA364, a near-infrared fluorescence arginine-glycine-aspartic acid cyclic probe, was taken up by neoplastic mammary glands and that its uptake increased with cancer progression. By contrast, the nonaccumulation of DA364 in the healthy mammary glands of virgin and lactating wild-type mice suggests that the probe specifically targets breast cancers. Comparisons of optical imaging with whole-mount and histological findings showed that DA364 allows the noninvasive visualization of atypical hyperplasia and microscopic foci of in situ carcinoma 2 months before mammary lesions become detectable by palpation. Moreover, DA364 was successfully used to monitor the outcome of anticancer vaccination. Therefore, it can be considered a promising early detection tool in near-infrared noninvasive optical imaging for the early diagnosis of breast cancer.


Subject(s)
Carbocyanines , Integrin alphaVbeta3/metabolism , Mammary Neoplasms, Experimental/diagnosis , Mammary Neoplasms, Experimental/metabolism , Peptides, Cyclic , Receptor, ErbB-2/metabolism , Animals , Female , Fluorescent Antibody Technique , Mice , Mice, Inbred BALB C , Mice, Transgenic , Receptor, ErbB-2/genetics
20.
J Med Chem ; 56(6): 2676-89, 2013 Mar 28.
Article in English | MEDLINE | ID: mdl-23458498

ABSTRACT

New fluorinated, arylsulfone-based matrix metalloproteinase (MMP) inhibitors containing carboxylate as the zinc binding group were synthesized as radiotracers for positron emission tomography. Inhibitors were characterized by Ki for MMP-2 in the nanomolar range and by a fair selectivity for MMP-2/9/12/13 over MMP-1/3/14. Two of these compounds were obtained in the (18)F-radiolabeled form, with radiochemical purity and yield suitable for preliminary studies in mice xenografted with a human U-87 MG glioblastoma. Target density in xenografts was assessed by Western blot, yielding Bmax/Kd = 14. The biodistribution of the tracer was dominated by liver uptake and hepatobiliary clearance. Tumor uptake of (18)F-labeled MMP inhibitors was about 30% that of [(18)F]fluorodeoxyglucose. Accumulation of radioactivity within the tumor periphery colocalized with MMP-2 activity (evaluated by in situ zimography). However, specific tumor uptake accounted for only 18% of total uptake. The aspecific uptake was ascribed to the high binding affinity between the radiotracer and serum albumin.


Subject(s)
Fluorine Radioisotopes , Glioblastoma/diagnostic imaging , Glioblastoma/pathology , Matrix Metalloproteinases/metabolism , Positron-Emission Tomography/methods , Sulfones/chemistry , Animals , Biological Transport , Cell Line, Tumor , Cell Transformation, Neoplastic , Chemistry Techniques, Synthetic , Humans , Mice , Protease Inhibitors/chemistry , Protease Inhibitors/metabolism , Protease Inhibitors/pharmacology , Radioactive Tracers , Radiochemistry , Serum Albumin/metabolism , Sulfones/metabolism , Sulfones/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...