1.
J Am Soc Mass Spectrom ; 27(4): 607-14, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26729450

ABSTRACT

This contribution reports on the development of an atmospheric pressure photoionization (APPI) source interfacing a gas chromatograph (GC) with a bench-top Orbitrap high resolution mass spectrometer (MS). We present efforts on method development aiming at high temperature stability (325°C), constant low impurity levels upon prolonged source operation, and efficient reaction volume irradiation combined with minimum peak broadening. The performance throughout each iterative development step was carefully assessed. The final GC-APPI-MS setup demonstrated femtogram-on-column sensitivity and chromatographic peaks of Gaussian shape with base peak widths <2 s for even the highest boiling compounds present in different EPA standard mixtures. Graphical Abstract ᅟ.

2.
Rapid Commun Mass Spectrom ; 28(14): 1591-600, 2014 Jul 30.
Article in English | MEDLINE | ID: mdl-24895256

ABSTRACT

RATIONALE: Atmospheric pressure chemical ionization (APCI) sources operated with point to plane DC discharges ('Coronas') frequently suffer from point electrode degradation and potentially lead to oxidation and/or fragmentation of the generated analyte ions. It is postulated that these adverse effects are caused by the interaction of these ions with the discharge chemistry as well as en route to the mass analyzer region. METHODS: The corona discharge metal point electrode is replaced by the conically shaped liquid effluent evolving from a fused-silica capillary, which is analogous but not identical to the Taylor cone formation in electrospray ionization. The liquid consisting of either pure water or water containing 0.1 %V formic acid is fed via a nano-flow delivery stage at typical flow rates between 1-800 µL/h. The liquid flow is continuously replenishing the surface of the point electrode. The source is directly coupled to the inlet capillary of appropriate mass spectrometers, e.g., the Bruker Daltonics and Agilent varieties. RESULTS: The actively pumped liquid flow is supplying a constant amount of the reagent gas (H2O) to the corona region in the 20 ppmV to 30 %V range, leading to controlled, very stable operation of the source. The typical light emission observed for corona discharges is in very close proximity to the aqueous surface. Analyte protonation is the dominating ionization pathway. The degree of primary analyte fragmentation is extremely low. CONCLUSIONS: We have developed a novel atmospheric pressure chemical ionization source designed for the hyphenation of nano-flow liquid chromatography and gas chromatography with atmospheric pressure ionization mass spectrometry. The proposed reaction mechanism including the electrochemistry occurring in the source along with formation of protonated analyte molecules via collision-induced dissociation (CID) is in full accord with the experimental results. The system exhibits an extremely stable performance over prolonged operation times, sole generation of protonated molecules, and low degree of analyte ion fragmentation.

3.
J Am Soc Mass Spectrom ; 25(8): 1310-21, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24850441

ABSTRACT

It is well documented since the early days of the development of atmospheric pressure ionization methods, which operate in the gas phase, that cluster ions are ubiquitous. This holds true for atmospheric pressure chemical ionization, as well as for more recent techniques, such as atmospheric pressure photoionization, direct analysis in real time, and many more. In fact, it is well established that cluster ions are the primary carriers of the net charge generated. Nevertheless, cluster ion chemistry has only been sporadically included in the numerous proposed ionization mechanisms leading to charged target analytes, which are often protonated molecules. This paper series, consisting of two parts, attempts to highlight the role of cluster ion chemistry with regard to the generation of analyte ions. In addition, the impact of the changing reaction matrix and the non-thermal collisions of ions en route from the atmospheric pressure ion source to the high vacuum analyzer region are discussed. This work addresses such issues as extent of protonation versus deuteration, the extent of analyte fragmentation, as well as highly variable ionization efficiencies, among others. In Part 1, the nature of the reagent ion generation is examined, as well as the extent of thermodynamic versus kinetic control of the resulting ion population entering the analyzer region.


Subject(s)
Air Ionization , Atmospheric Pressure , Models, Chemical , Air Ionization/radiation effects , Chemical Phenomena/drug effects , Indicators and Reagents/chemistry , Indicators and Reagents/radiation effects , Light , Photochemical Processes , Spatio-Temporal Analysis , Thermodynamics
4.
Rev Sci Instrum ; 85(1): 014102, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24517784

ABSTRACT

In this study a thermally sampling atmospheric pressure ionization mass spectrometer is described and characterized. The ion transfer stage offers the capability to sample cluster ions at thermal equilibrium and during this transfer fundamental processes possibly affecting the cluster distribution are also readily identified. Additionally, the transfer stage combines optional collision-induced dissociation (CID) analysis of the cluster composition with thermal equilibrium sampling of clusters. The performance of the setup is demonstrated with regard to the proton-bound water cluster system. The benefit of the studied processes is that they can help to improve future transfer stages and to understand cluster ion reactions in ion mobility tubes and high-pressure ion sources. In addition, the instrument allows for the identification of fragmentation and protonation reactions caused by CID.

5.
J Am Soc Mass Spectrom ; 25(3): 329-42, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24399666

ABSTRACT

We report on a novel method for atmospheric pressure ionization of compounds with elevated electron affinity (e.g., nitroaromatic compounds) or gas phase acidity (e.g., phenols), respectively. The method is based on the generation of thermal electrons by the photo-electric effect, followed by electron capture of oxygen when air is the gas matrix yielding O2(-) or of the analyte directly with nitrogen as matrix. Charge transfer or proton abstraction by O2(-) leads to the ionization of the analytes. The interaction of UV-light with metals is a clean method for the generation of thermal electrons at atmospheric pressure. Furthermore, only negative ions are generated and neutral radical formation is minimized, in contrast to discharge- or dopant assisted methods. Ionization takes place inside the transfer capillary of the mass spectrometer leading to comparably short transfer times of ions to the high vacuum region of the mass spectrometer. This strongly reduces ion transformation processes, resulting in mass spectra that more closely relate to the neutral analyte distribution. cAPECI is thus a soft and selective ionization method with detection limits in the pptV range. In comparison to standard ionization methods (e.g., PTR), cAPECI is superior with respect to both selectivity and achievable detection limits. cAPECI demonstrates to be a promising ionization method for applications in relevant fields as, for example, explosives detection and atmospheric chemistry.


Subject(s)
Nitrophenols/analysis , Nitrophenols/chemistry , Spectrometry, Mass, Electrospray Ionization/instrumentation , Spectrometry, Mass, Electrospray Ionization/methods , Atmospheric Pressure , Electrons , Equipment Design , Kinetics , Oxidation-Reduction
6.
J Am Soc Mass Spectrom ; 22(11): 2061-9, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21952755

ABSTRACT

In this study, the validation and analysis of steady state numerical simulations of the gas flows within a multi-purpose ion source (MPIS) are presented. The experimental results were obtained with particle image velocimetry (PIV) measurements in a non-scaled MPIS. Two-dimensional time-averaged velocity and turbulent kinetic energy distributions are presented for two dry gas volume flow rates. The numerical results of the validation simulations are in very good agreement with the experimental data. All significant flow features have been correctly predicted within the accuracy of the experiments. For technical reasons, the experiments were conducted at room temperature. Thus, numerical simulations of ionization conditions at two operating points of the MPIS are also presented. It is clearly shown that the dry gas volume flow rate has the most significant impact on the overall flow pattern within the APLI source; far less critical is the (larger) nebulization gas flow. In addition to the approximate solution of Reynolds-Averaged Navier-Stokes equations, a transport equation for the relative analyte concentration has been solved. The results yield information on the three-dimensional analyte distribution within the source. It becomes evident that for ion transport into the MS ion transfer capillary, electromagnetic forces are at least as important as fluid dynamic forces. However, only the fluid dynamics determines the three-dimensional distribution of analyte gas. Thus, local flow phenomena in close proximity to the spray shield are strongly impacting on the ionization efficiency.

7.
J Am Soc Mass Spectrom ; 22(11): 2070-81, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21952756

ABSTRACT

We report on the development of a novel atmospheric pressure photoionization setup and its applicability for in situ degradation product studies of atmospherically relevant compounds. A custom miniature spark discharge lamp was embedded into an ion transfer capillary, which separates the atmospheric pressure from the low pressure region in the first differential pumping stage of a conventional atmospheric pressure ionization mass spectrometer. The lamp operates with a continuous argon flow and produces intense light emissions in the VUV. The custom lamp is operated windowless and efficiently illuminates the sample flow through the transfer capillary on an area smaller than 1 mm(2). Limits of detection in the lower ppbV range, a temporal resolution of milliseconds in the positive as well as the quasi simultaneously operating negative ion mode, and a significant reduction of ion transformation processes render this system applicable to real time studies of rapidly changing chemical systems. The method termed capillary atmospheric pressure photo ionization (cAPPI) is characterized with respect to the lamp emission properties as a function of the operating conditions, temporal response, and its applicability for in situ degradation product studies of atmospherically relevant compounds, respectively.

8.
J Am Soc Mass Spectrom ; 22(6): 1063-9, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21953047

ABSTRACT

The performance of a KrF* bench top excimer laser and a compact diode pumped UV solid state (DPSS) Nd:YAG laser as photo-ionizing source in LC-APLI MS is compared. The commonly applied bench-top excimer laser, operating at 248 nm, provides power densities of the order of low MW/cm(2) on an illuminated area of 0.5 cm(2) (8 mJ/pulse, 5 ns pulse duration, beam waist area 0.5 cm(2), 3 MW/cm(2)). The DPSS laser, operating at 266 nm, provides higher power densities, however, on a two orders of magnitude smaller illuminated area (60 µJ/pulse, 1 ns pulse duration, beam waist area 2 × 10(-3) cm(2), 30 MW/cm(2)). In a common LC-APLI MS setup with direct infusion of a 10 nM pyrene solution, the DPSS laser yields a significantly smaller ion signal (0.9%) and signal to noise ratio (1.4%) compared with the excimer laser. With respect to the determined low detection limits (LODs) for PAHs of 0.1 fmol using an excimer laser, LODs in DPSS laser LC-APLI MS in the low pmol regime are expected. The advantages of the DPSS laser with respect to applicability (size, cost, simplicity) may render this light source the preferred one for APLI applications not focusing on ultimately high sensitivities. Furthermore, the impact of adjustable ion source parameters on the performance of both laser systems is discussed in terms of the spatial sensitivity distribution described by the distribution of ion acceptance (DIA) measurements. Perspectives concerning the impact on future APLI-MS applications are given.

9.
Rapid Commun Mass Spectrom ; 25(16): 2317-26, 2011 Aug 30.
Article in English | MEDLINE | ID: mdl-21769956

ABSTRACT

The analysis of crude oil samples remains a tough challenge due to the complexity of the matrix and the broad range of physical and chemical properties of the various individual compounds present. In this work, atmospheric pressure laser ionization (APLI) is utilized as a complementary tool to other ionization techniques for crude oil analysis. Mass spectra obtained with electrospray ionization (ESI) and atmospheric pressure photoionization (APPI) are compared. APLI is primarily sensitive towards non-polar aromatic hydrocarbons, which are generally present in high amounts especially in heavy crude oil samples. The ionization mechanisms of APLI vs. APPI are further investigated. The results indicate the advantages of APLI over established methods like ESI and APPI. The application of APLI in combination with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is thus demonstrated to be a powerful tool for the analysis of aromatic species in complex crude oil fractions.

10.
J Am Soc Mass Spectrom ; 20(10): 1868-80, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19660964

ABSTRACT

We report on the reactions of neutral radical species [OH, Cl, O(3P), H], generated in a typical atmospheric pressure ionization (API) source upon irradiation of the sample gases with either 193 nm laser radiation or 124 nm VUV light, the latter commonly used in atmospheric pressure photoionization (APPI). The present investigations focus on the polycyclic aromatic hydrocarbon pyrene as representative of the aromatic compound class. Experimental results are supported by computational methods: simple kinetic models are used to estimate the temporal evolution of the concentrations of reactants, intermediates, and final products, whereas density functional theory (DFT) energy calculations are carried out to further elucidate the proposed reaction pathways. The neutral radicals are generated upon photolysis of background water and oxygen always present in appreciable mixing ratios in typical API sources. Substantial amounts of oxygenated analyte product ions are observed using both techniques. In contrast, upon atmospheric pressure laser ionization (APLI) with 248 nm radiation, oxygenated products are virtually absent. In addition, kinetic data evaluation yielded a bimolecular rate constant of k = (1.9 +/- 0.9) x 10(-9) cm3 molecule(-1) s(-1) for the reaction of the pyrene radical cation with OH radicals.

11.
Analyst ; 133(7): 867-9, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18575636

ABSTRACT

We report on the successful application of the recently introduced atmospheric pressure laser ionization (APLI) method as a novel tool for the analysis of crude oil and its components. Using Fourier transform ion cyclotron resonance mass spectrometry, unambiguous determination of key compounds in this complex matrix with unprecedented sensitivity is presented.

12.
Anal Bioanal Chem ; 391(8): 2803-9, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18566804

ABSTRACT

Recently we have established atmospheric-pressure laser ionisation (APLI) as a method for coupling time-of-flight mass spectrometric detectors (TOF MS) with chromatographic systems (HPLC and GC) to allow two-photon ionisation of non-polar aromatic compounds. Here we demonstrate that APLI can be combined with chip-electrospray ionisation (cESI) coupled to Fourier-transform-ion cyclotron resonance mass spectrometry (FT-ICR MS) for ultrahigh-resolution analysis of complex samples. With the laser turned off, the analytes are ionised only by ESI, whereas when the laser is switched on non-polar aromatic substances also are ionised. In combination with the extremely high mass resolution of an FT-ICR MS, simultaneous qualitative analysis of polar and non-polar analytes is possible in both positive and negative modes, as is exemplified with a crude oil sample. Nevertheless, ion suppression was observed (up to ca. 70% for D(10)-pyrene) and thus sample preparation with chromatographic or electrophoretic pre-separation is necessary for quantitative analysis of targets. In addition, for the first time, the dopant-assisted APLI method in combination with cESI (DA-cESILI) was used for determination of 1-nitrocoronene.


Subject(s)
Benzo(a)pyrene/analysis , Spectrometry, Mass, Electrospray Ionization/instrumentation , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation , Acetonitriles/chemistry , Atmospheric Pressure , Fourier Analysis , Molecular Structure , Polycyclic Compounds/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
13.
J Am Soc Mass Spectrom ; 19(3): 400-10, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18187335

ABSTRACT

It is demonstrated that spatially resolved mass selected analysis using atmospheric pressure laser ionization mass spectrometry (APLI MS) represents a new powerful tool for mechanistic studies of ion-molecule chemistry occurring within atmospheric pressure (AP) ion sources as well as for evaluation and optimization of ion source performance. A focused low-energy UV laser beam is positioned computer controlled orthogonally on a two-dimensional grid in the ion source enclosure. Resonance enhanced multiphoton ionization (REMPI) of selected analytes occurs only within the confined volume of the laser beam. Depending on the experimental conditions and the reactivity of the primary photo-generated ions, specific signal patterns become visible after data treatment, as visualized in, e.g., contour or pseudo-color plots. The resulting spatial dependence of sensitivity is defined in this context as the distribution of ion acceptance (DIA) of the source/analyzer combination. This approach provides a much more detailed analysis of the diverse processes occurring in AP ion sources compared with conventional bulk signal response measurements.

14.
Electrophoresis ; 26(21): 4098-103, 2005 Nov.
Article in English | MEDLINE | ID: mdl-16252331

ABSTRACT

We describe the successful coupling of CEC and capillary HPLC with the recently developed atmospheric-pressure laser ionization (APLI) method. APLI is suitable for selectively and sensitively ionizing nonpolar aromatic compounds at ambient pressure for subsequent mass-selective detection. The polycyclic aromatic hydrocarbons used as analytes are first separated either by CEC on a silica-based monolithic column or by capillary HPLC. The eluent, along with a sheath flow, is volatilized by microelectrospray and then selectively ionized by excimer laser (KrF*) radiation via two-photon excitation. A QTOF-MS is used as mass-selective detector. This interface combination makes soft ionization of thermally labile nonpolar aromatic analytes possible.


Subject(s)
Chromatography, High Pressure Liquid/methods , Electrophoresis, Capillary/methods , Polycyclic Aromatic Hydrocarbons/isolation & purification , Spectrometry, Mass, Electrospray Ionization/methods , Chromatography, High Pressure Liquid/instrumentation , Electrophoresis, Capillary/instrumentation , Equipment Design , Silicon Dioxide , Spectrometry, Mass, Electrospray Ionization/instrumentation