Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 70
Filter
1.
J Electromyogr Kinesiol ; 23(4): 879-85, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23557977

ABSTRACT

The intramuscular activation pattern can be connected to the motor unit recruitment strategy of force generation and fatigue resistance. Electromyography has earlier been used in several studies to quantify the spatial inhomogeneity of the muscle activation. We applied ultrasound M-mode strain to study the activation pattern through the tissue deformation. Correlation values of the strain at different force levels were used to quantify the spatial changes in the activation. The assessment was done including the biceps brachii muscle of 8 healthy subjects performing isometric elbow flexion contractions ranging from 0% to 80% of maximum voluntary contraction. The obtained results were repeatable and demonstrated consistent changes of the correlation values during force regulation, in agreement with previously presented EMG-results. Both intra-subject and inter-subject activation patterns of strain were considered along and transverse the fiber direction. The results suggest that ultrasound M-mode strain can be used as a complementary method to study intramuscular activation patterns with high spatial resolution.


Subject(s)
Elasticity Imaging Techniques/methods , Image Interpretation, Computer-Assisted/methods , Isometric Contraction/physiology , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Physical Exertion/physiology , Recruitment, Neurophysiological/physiology , Adult , Elbow/physiology , Excitation Contraction Coupling/physiology , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
2.
Ultrasound Obstet Gynecol ; 38(4): 413-7, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21936002

ABSTRACT

OBJECTIVES: The high velocity and short duration of myocardial motion requires a high sampling rate to obtain adequate temporal resolution; this issue becomes even more important when taking into consideration the high fetal heart rate. In this study we have established optimal sampling requirements for assessing the duration of various cardiac cycle events and myocardial velocities of the fetal heart using color-coded tissue velocity imaging (TVI). METHODS: Recordings from 30 fetuses were acquired at an initial frame rate of 180-273 frames/s. All TVI recordings were performed from an apical four-chamber view and stored as cineloops of five to 10 consecutive cardiac cycles for subsequent offline analysis using software enabling a reduction in frame rate. Different components of the myocardial velocity curve, obtained from the basal part of the ventricular septum, were measured at the initial frame rate and compared with their equivalents at gradually decreased frame rates. RESULTS: As acquisition frame rate was reduced, there was a marked increase in deviation from the initial values, resulting in an underestimation of all systolic and diastolic velocities. For the measured durations, there was a clear tendency to underestimate isovolumetric contraction and relaxation, and a clear tendency to overestimate ventricular ejection and diastolic E-wave and A-wave. An acceptable ⩽ 5% deviation from the value obtained at the highest frame rate corresponded to measurements obtained at above 150-200 frames/s. CONCLUSIONS: A high sampling rate of at least 200 frames/s is necessary for adequate reconstruction of TVI data for the fetal heart. Frame rates that are too low result in considerable loss of temporal and velocity information.


Subject(s)
Blood Flow Velocity , Echocardiography, Doppler, Color , Fetal Heart/diagnostic imaging , Stroke Volume , Female , Fetal Heart/physiopathology , Gestational Age , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Image Processing, Computer-Assisted , Pregnancy
4.
Acta Physiol Scand ; 182(1): 45-51, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15329056

ABSTRACT

AIM: The objective was to assess left ventricular (LV) volumes at rest and during upright submaximal exercise in endurance athletes to see whether changes in heart volume could explain the large predicted increase in cardiac output in endurance athletes. METHOD: Contrast echocardiography was used to assess changes in LV volumes during upright bicycle exercise in 24 healthy male endurance athletes. Maximal oxygen uptake and oxygen pulse were measured by using cardiopulmonary exercise testing. RESULTS: From rest to exercise at a heart rate of 160 beats min(-1) end-diastolic volume increased by 18% (P < 0.001) and end-systolic volume decreased by 21% (P = 0.002). Stroke volume showed an almost linear increase during exercise (45% increase, P < 0.001). The increase in end-diastolic volume contributed to 73% of the increase in stroke volume. No significant differences were observed between stroke volume calculated from LV volumes with contrast echocardiography and stroke volume calculated from oxygen pulse at heart rates of 130 and 160 beats min(-1). Using the linear regression equation between oxygen uptake and cardiac output assessed by echocardiography during exercise (r=0.87, P=0.002), cardiac output at maximal exercise was estimated at 33 +/- 3 L min(-1), with an estimated increase in stroke volume by 69% from rest to maximal exercise. CONCLUSION: By using contrast echocardiography, a large increase in stroke volume in endurance athletes could be explained by an almost linear increase in end-diastolic volume and an initial small decrease in end-systolic volume during incremental upright exercise.


Subject(s)
Echocardiography/methods , Exercise/physiology , Physical Endurance/physiology , Ventricular Function, Left/physiology , Adult , Cardiac Output/physiology , Exercise Test , Heart Rate/physiology , Humans , Male , Stroke Volume/physiology
5.
Eur J Echocardiogr ; 5(4): 284-93, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15219543

ABSTRACT

AIMS: To describe the normal myocardial velocity profile during the isovolumic contraction and relaxation period at four different locations within left ventricular base and to establish normal age and gender related isovolumic time and velocity values. METHODS AND RESULTS: In 49 healthy individuals (26 women/23 men) in age groups 21-49 and 50-76 years, tissue velocity profiles and 2D-data were acquired at high temporal resolution (90-147 frames/s) for a subsequent off-line analysis using software enabling retrieval of myocardial Doppler velocity and 2D/anatomical M-mode information from different cardiac locations during the same cardiac cycle. The obtained velocity curves during the isovolumic contraction and relaxation period were usually biphasic and displayed clear regional differences in their respective positive and negative maximal velocities. Besides some gender related differences, mainly in the duration of the positive and negative velocity wave components during the isovolumic contraction period, a clear age-dependent increase in the duration of the isovolumic relaxation phase and its negative and positive velocity components was observed. CONCLUSION: Modern tissue Doppler imaging supplemented by anatomical M-mode images of the mitral and aortic valve movements allows a proper analysis of the rapid isovolumic myocardial movements. The presented normal isovolumic time and velocity values may prove useful for studies of myocardial function.


Subject(s)
Blood Flow Velocity/physiology , Myocardial Contraction/physiology , Stroke Volume/physiology , Adult , Age Factors , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiology , Coronary Circulation/physiology , Echocardiography, Doppler, Color , Female , Heart Ventricles/diagnostic imaging , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiology , Reference Values , Sex Factors , Ventricular Function
6.
Eur Heart J ; 24(17): 1584-94, 2003 Sep.
Article in English | MEDLINE | ID: mdl-12927194

ABSTRACT

AIMS: To develop optimal methods for the objective non-invasive diagnosis of coronary artery disease, using myocardial Doppler velocities during dobutamine stress echocardiography. METHODS AND RESULTS: We acquired tissue Doppler digital data during dobutamine stress in 289 subjects, and measured myocardial responses by off-line analysis of 11 left ventricular segments. Diagnostic criteria developed by comparing 92 normal subjects with 48 patients with coronary disease were refined in a prospective series of 149 patients referred with chest pain. Optimal diagnostic accuracy was achieved by logistic regression models, using systolic velocities at maximal stress in 7 myocardial segments, adjusting for independent correlations directly with heart rate and inversely with age and female gender (all p<0.001). Best cut-points from receiver-operator curves diagnosed left anterior descending, circumflex and right coronary disease with sensitivities and specificities of 80% and 80%, 91% and 80%, and 93% and 82%, respectively. All models performed better than velocity cut-offs alone (p<0.001). CONCLUSION: Non-invasive diagnosis of coronary artery disease by quantitative stress echocardiography is best performed using diagnostic models based on segmental velocities at peak stress and adjusting for heart rate, and gender or age.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Adult , Aged , Blood Flow Velocity , Cardiotonic Agents , Coronary Artery Disease/physiopathology , Dopamine , Echocardiography, Doppler , Echocardiography, Stress/methods , Female , Humans , Male , Middle Aged , Prospective Studies , Regression Analysis
7.
Eur J Echocardiogr ; 4(1): 43-53, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12565062

ABSTRACT

AIMS: Off-line post-processing of colour tissue Doppler from digital loops may allow objective quantification of dobutamine stress echocardiography. We assessed the reproducibility of off-line measurements of regional myocardial velocities. METHODS AND RESULTS: Nine observers analysed 10 studies, each making 2400 observations. Coefficients of variation in basal segments from apical windows, at rest and maximal stress, were 9-14% and 11-18% for peak systolic velocity, 16-18% and 17-19% for time-to-peak systolic velocity, 9-17% and 18-24% for systolic velocity time integral, and 18-23% and 21-27% for systolic acceleration. Coefficients of variation for diastolic velocities in basal segments at rest were 11-40%. Coefficients of variation for peak systolic velocity were 10-24% at rest and 14-28% at peak in mid segments, and 19-53% and 29-69% in apical segments. From parasternal windows coefficients of variation for peak systolic velocity were 14-16% in basal posterior, and 19-29% in mid-anterior segments. High variability makes measurement unreliable in apical and basal anterior septal segments. The feasibility of obtaining traces was tested in 92 subjects, and >90% in all basal and mid segments apart from the anterior septum. CONCLUSION: Quantification of myocardial functional reserve by off-line analysis of colour tissue Doppler acquired during dobutamine stress is feasible and reproducible in 11 segments of the left ventricle. The most reliable measurements are systolic velocities of longitudinal motion in basal segments.


Subject(s)
Echocardiography, Doppler, Color , Echocardiography, Stress , Image Processing, Computer-Assisted , Myocardial Ischemia/diagnostic imaging , Blood Flow Velocity , Feasibility Studies , Humans , Myocardial Ischemia/physiopathology , Observer Variation , Reproducibility of Results
8.
Eur J Cardiothorac Surg ; 22(6): 912-21, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12467813

ABSTRACT

OBJECTIVE: The long-term durability and hemodynamics of stentless valves are largely unknown. Our aim was to prospectively investigate long-term hemodynamic function and clinical outcome after aortic valve replacement with the Biocor stentless aortic bioprosthesis. PATIENTS AND METHODS: Between October 1990 and November 2000 we inserted the Biocor stentless aortic valve in 112 patients (male/female: 38:74) with a mean age of 78.5 years (median 79.3, range 60-88). The predominant diagnosis was aortic stenosis in 86% of the patients. Concomitant coronary artery bypass surgery was performed in 31% of the patients. Average prosthetic valve size was 23.3+/-1.6 mm. All patients were followed in a prospective study with a mean follow-up of 66+/-33 months. The follow-up was 100% complete with a closing interval from October 1 to December 31, 2001. The observed actuarial survival of patients was compared to expected survival for an age- and gender-matched comparison population as calculated from Swedish life tables by Statistics Sweden. Relative survival rates were calculated annually for the patient population. RESULTS: Early mortality was 7% (8/112). Late mortality was 38% (43/112). Actuarial survival at 5 and 9 years was 74+/-5% and 38+/-7%, respectively. Observed survival among patients was not different from the expected survival for the comparison population and calculation of relative survival rates indicates a 'normalized' survival pattern for the patient population. At 5 and 9 years the actuarial freedom from valve-related death was 94+/-3% and 86+/-6%; from cardiac death, 82+/-4% and 57+/-8%; from valve reoperation, 96+/-2% and 87+/-6%; from structural valve degeneration, 96+/-2% and 87+/-6%; from thromboembolism, 89+/-4% and 71+/-9%; and from endocarditis, 96+/-2% and 90+/-5%. At 9 years the transvalvular mean pressure difference for all valves was 7.3+/-1.3 mmHg (range 6-10 mmHg) measured with Doppler echocardiography. Aortic regurgitation progressed slowly over time in a few patients and necessitated reoperation in two patients. CONCLUSION: The Biocor stentless bioprosthesis has an excellent hemodynamic function and confers a good long-term outcome. This patient population could be regarded as 'cured' from valve disease since the observed survival did not differ from the expected survival for an age- and gender-matched Swedish comparison population, a conclusion that is also supported by a constant relative survival after the first postoperative year. However, despite excellent long-term hemodynamics, patients with stentless bioprostheses need to be evaluated with echocardiography at regular intervals to discover the rare cases of progressive aortic regurgitation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Echocardiography, Doppler , Female , Follow-Up Studies , Heart Valve Prosthesis Implantation/methods , Hemodynamics , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Failure , Reoperation , Survival Analysis , Treatment Outcome
9.
Med Biol Eng Comput ; 40(5): 512-9, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12452410

ABSTRACT

Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, sinus rhythm 100.3 +/- 16.5 beats min(-1), average impedance 629.8 +/- 72.6 ohms; and two dogs: 30 kg each, sinus rhythm 86.0 beats min(-1), 862.1 ohms and 134.0 beats min(-1), 1114.6 ohms, respectively). The averaged curve and standard deviation curve of the impedance in sinus rhythm were analysed in MATLAB to clarify and study consistent impedance shape over one heart cycle. In eight of nine (89%) animal subjects, a consistent impedance slope change (notch) was observed in the early stage of the cardiac filling phase. This result was reproduced in an additional subject with simultaneous echocardiographical measurements of mitral valve blood flow. The notch occured soon after rapid early filling (E-wave in mitral flow) but prior to ventricular filling caused by atrial contraction, indicating that the impedance notch was caused by rapid ventricular filling and that it might be a sensed feature of diagnostic value. The intracardiac impedance notch in the present study had similar features to the non-invasive transthoracic impedance O-wave reported by others, and it is shown here that an O-wave is found in intracardiac impedance signals, strongly suggesting that the non-invasive O-wave is caused by cardiac events.


Subject(s)
Heart Conduction System/physiology , Pacemaker, Artificial , Ventricular Function, Right/physiology , Animals , Dogs , Electric Impedance , Electrocardiography , Sheep
10.
Eur J Echocardiogr ; 3(3): 214-9, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12144841

ABSTRACT

AIMS: Movements of myocardial walls include components of high velocity and short duration calling for a high sampling rate in the acquisition of tissue velocity imaging data. This study aims at establishing the optimal sampling requirements for tissue velocity imaging measurements. METHODS AND RESULTS: In 16 healthy individuals, tissue velocity imaging data were acquired at a frame rate of 141-203 frames/s for a subsequent off-line analysis using software enabling a reduction of the sampling rate to 50%, 25% and 12.5% of the initial frame rate. Different components of the myocardial velocity profile were measured at each of these frame rates. The deviation of the results from the initial values increased markedly at decreasing frame rates, producing an underestimation of peak systolic and diastolic velocities, most other measured parameters being overestimated. A cut-off point for an acceptable < or =10% deviation of the results corresponded to at least 70 frames/s for peak systolic and early diastolic velocity, and to at least 100 frames/s for other systolic and diastolic parameters. CONCLUSION: A high sampling rate is essential for a proper rendering of tissue velocity imaging signals, too low frame rates resulting in inferior accuracy of the results. This should be kept in mind while viewing reported tissue velocity imaging data.


Subject(s)
Blood Flow Velocity/physiology , Echocardiography, Doppler , Heart/physiology , Image Processing, Computer-Assisted , Adolescent , Adult , Diastole/physiology , Electrocardiography , Female , Humans , Male , Middle Aged , Myocardial Contraction/physiology , Reference Values , Sampling Studies , Stroke Volume/physiology , Systole/physiology
11.
Clin Sci (Lond) ; 102(5): 515-22, 2002 May.
Article in English | MEDLINE | ID: mdl-11980570

ABSTRACT

Impaired long-axis motion is a sensitive marker of systolic myocardial dysfunction, but no data are available that relate long-axis changes in systole with those in diastole, particularly in subjects with diastolic dysfunction and a 'normal' left ventricular (LV) ejection fraction. A total of 311 subjects (including 105 normal healthy volunteers) aged 20-89 years with variable degrees of systolic function (LV ejection fraction range 0.15-0.84) and diastolic function were studied using tissue Doppler echocardiography and M-mode echocardiography to determine mean mitral annular amplitude and peak velocity in systole and early and late diastole. The LV systolic mitral annular amplitude (S(LAX), where LAX is long-axis amplitude) and peak velocity (S(m)) correlated well with the respective early diastolic components (E(LAX) and E(m)) and late diastolic (atrial) components (A(LAX) and A(m)). A non-linear equation fitted better than a linear relationship (non-linear model: S(LAX) against E(LAX), r(2)=0.67; S(m) against E(m), r(2)=0.60; S(LAX) against A(LAX) and S(m) against A(m), r(2)=0.42). After adjusting for age, sex and heart rate, linear relationships of early diastolic (E(LAX), r(2)=0.70; E(m), r(2)=0.60) and late diastolic (A(LAX), r(2)=0.61; A(m), r(2)=0.64) long-axis amplitudes and velocities with the respective values for S(LAX) and S(m) were found, even in those subjects with apparently 'isolated' diastolic dysfunction. Long-axis changes in systole or diastole did not correlate with Doppler mitral velocities. We conclude that ventricular long-axis changes in early diastole are closely related to systolic function, even in subjects with diastolic dysfunction. 'Pure' or isolated diastolic dysfunction is uncommon.


Subject(s)
Diastole , Systole , Ventricular Dysfunction, Left/physiopathology , Adult , Age Distribution , Aged , Aged, 80 and over , Aging/physiology , Blood Flow Velocity , Echocardiography, Doppler , Female , Humans , Linear Models , Male , Middle Aged , Mitral Valve/physiopathology , Sex Distribution , Stroke Volume , Ventricular Dysfunction, Left/diagnostic imaging
12.
Acta Anaesthesiol Scand ; 46(5): 552-60, 2002 May.
Article in English | MEDLINE | ID: mdl-12027850

ABSTRACT

BACKGROUND: Previous studies have shown that pneumoperitoneum transiently reduces venous admixture as assessed by a calculation based on the shunt formula, and increases arterial oxygen tension (PaO(2)) in patients without heart or lung disease. The aim of the present study was to further explore the relationship between ventilation-perfusion (V(A)/Q) before and during pneumoperitoneum by using the multiple inert gas technique. METHODS: Nine patients without heart or lung disease (ASA I), with a mean age of 42 years, scheduled for laparoscopic cholecystectomy were included. After premedication and induction of anaesthesia, radial artery and pulmonary artery catheters were introduced percutaneously. The V(A)Q relationships were evaluated by the multiple inert gas elimination technique before and during pneumoperitoneum to obtain a direct measure of the pulmonary shunt. RESULTS: Induction of pneumoperitoneum decreased the pulmonary shunt from 5.8 (4.5) to 4.1 (3.2)% (P<0.05) and increased PaO(2) from 21.7 (5.9) to 24.7 (4.8) kPa (P<0.01). During surgery, the shunt increased from 3.2 (2.8) to 5.2 (3.4)% to the same level as before pneumoperitoneum induction. No area with low V(A)Q was seen. Dead space ventilation amounted to 20.0 (1.2)% in the supine position and did not change during the investigation. CONCLUSIONS: In patients without heart or lung disease, pneumoperitoneum at an intra-abdominal pressure level of 11-13 mmHg causes a transient reduction of the pulmonary shunt. The mechanisms underlying the present finding remain to be elucidated.


Subject(s)
Carbon Dioxide , Cholecystectomy, Laparoscopic/adverse effects , Pneumoperitoneum/physiopathology , Ventilation-Perfusion Ratio/physiology , Adult , Anesthesia , Blood Volume/physiology , Catheterization , Female , Hemodynamics/physiology , Humans , Hydrogen-Ion Concentration , Hypercapnia/blood , Male , Middle Aged , Noble Gases , Pulmonary Gas Exchange , Respiratory Function Tests
13.
Pediatr Cardiol ; 23(2): 152-9, 2002.
Article in English | MEDLINE | ID: mdl-11889526

ABSTRACT

Our objective was to compare the effects of surgical and device closure of atrial septal defects (ASDs) on atrioventricular plane function. In healthy individuals, both short- and long-axis motion contribute to ventricular pump function. Short-axis function (i.e., the amplitude and velocity of atrioventricular plane movements) may be evaluated by M-mode and Doppler tissue imaging. The study group consisted of 19 children with ASD of the secundum type before and after surgical (n = 12) or device (n = 7) closure and 10 healthy controls. Surgical and device closures were uncomplicated and all defects were completely closed. Registrations of atrioventricular plane systolic and diastolic amplitude and velocity were made from the tricuspid and the mitral annulus and from the septum in the apical four-chamber view. Comparisons were made between examinations before and after closure, between the two subgroups of patients treated by surgical and device closure, respectively, and between the patient group and the control groups. Before ASD closure, all measurements were normal or near normal. After surgery, systolic amplitudes and velocities of the tricuspid annulus and in the septum decreased significantly, whereas no changes were seen in the device group. Less marked changes were seen in diastolic measurements. However, in the surgical group significant decrease to subnormal values were found in the tricuspid annulus and in the septum, which may indicate a decreased diastolic function postoperatively. Mitral valve annulus amplitude and velocity were not affected by the treatment. Atrioventricular function is normal in children with right ventricular volume overload. The decrease to subnormal values after open-heart surgery is not seen after device closure of the ASD, indicating that surgery affects right ventricular function.


Subject(s)
Echocardiography, Doppler , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/physiopathology , Adolescent , Child , Child, Preschool , Diastole , Female , Heart Septal Defects, Atrial/therapy , Hemodynamics , Humans , Infant , Male , Prostheses and Implants , Ventricular Dysfunction, Right/physiopathology
14.
Am J Forensic Med Pathol ; 22(1): 58-61, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11444664

ABSTRACT

Large coronary fistulas are considered to cause myocardial ischemia due to diversion of the coronary blood flow. In this case the authors report the reverse effect--the spontaneous closure of a large fistulation between the left circumflex artery and the coronary sinus evoked angina pectoris in a middle aged man, who died several years later. Postmortem examination revealed a coronary aneurysm that had ruptured and dissected into the coronary sinus and finally thrombosed. The origin of the aneurysm could be congenital but perhaps also represents a healed stage of Kawasaki disease.


Subject(s)
Coronary Aneurysm/pathology , Autopsy , Coronary Angiography , Death, Sudden , Diagnosis, Differential , Forensic Medicine , Humans , Male , Middle Aged , Mucocutaneous Lymph Node Syndrome/diagnosis , Rupture, Spontaneous
15.
Scand Cardiovasc J ; 35(2): 129-35, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11405489

ABSTRACT

OBJECTIVES: To investigate whether acute volume changes in single volume segments of the left ventricle can be correlated with global volume changes. If so, changes in global volume might be predicted from changes in segmental volumes. DESIGN: Volume changes were recorded in six pigs in five intraventricular segments, from apex to heart base, using the conductance catheter (at baseline, after 60 min of apical ischaemia, during preload reduction and afterload increase). A computer algorithm was created to calculate the instantaneous absolute difference between the curve shape of global and normalized segmental volume as a percentage of global stroke volume. RESULTS: For a mid-cardiac volume segment constituting 34 (14-39)% [median (range)] of global stroke volume, the mean difference over a cardiac cycle was 4 (1-8)% at baseline. Apical ischaemia resulted in apical dyskinesia, but did not influence the mid-cardiac segment. CONCLUSIONS: The volume curve from a segment at mid-cardiac level seems to be a good estimator of the global volume curve, thus giving a foundation for estimation of global volume changes from such a segment.


Subject(s)
Cardiac Volume/physiology , Stroke Volume/physiology , Ventricular Function, Left/physiology , Animals , Cardiac Catheterization/methods , Hemodynamics/physiology , Models, Cardiovascular , Myocardial Contraction/physiology , Predictive Value of Tests , Swine
16.
Coron Artery Dis ; 12(3): 239-43, 2001 May.
Article in English | MEDLINE | ID: mdl-11352080

ABSTRACT

BACKGROUND: Myocardial tissue velocity and perfusion were studied in patients with severe angina pectoris following gene therapy by intramyocardial injection of phVEGF-A165 via thoracotomy. Plasma concentrations of VEGF-A increased postoperatively. Two months after treatment anginal status and myocardial tissue velocity improved and perfusion showed a tendency to improve. Tissue velocity imaging appears to be a sensitive, objective method for detecting changes in myocardial function following gene therapy. OBJECTIVE: To study effects on myocardial tissue velocity and perfusion in patients with angina pectoris following intramyocardial injection of phVEGF-A165 via thoracotomy. DESIGN: Open label, phase I/II. METHODS: Six patients with Canadian Cardiovascular Society (CCS) angina pectoris functional class III - IV and with major defects at adenosine stress single-photon emission computerized tomography (SPECT) were studied. In addition to SPECT, coronary angiography and dobutamine stress echocardiography with tissue Doppler velocity imaging were performed before and two months after gene transfer. RESULTS: Plasma concentrations of VEGF-A increased 2 to 3 times (P < 0.04) over baseline from 2 to 14 days after injection with normalization after 4 weeks. The CCS class improved about 40%, from 3.3 +/- 0.2 to 2.0 +/- 0.3 (P < 0.02) and nitroglycerine consumption decreased 30 - 40%, from 44 +/- 17 to 15 +/- 5 tablets per week (P < 0.05). The maximal systolic myocardial tissue velocity increased in all patients about 25% (P < 0.02) but did not reach the reference range. Myocardial perfusion at SPECT improved in four of the six patients. CONCLUSIONS: Anginal status, myocardial tissue velocity and perfusion can be improved by phVEGF-A165 intramyocardial injection. Tissue velocity imaging appears to be a sensitive, objective method for detecting changes in myocardial function following gene therapy.


Subject(s)
Angina Pectoris/diagnostic imaging , Angina Pectoris/therapy , Endothelial Growth Factors/therapeutic use , Genetic Therapy , Plasmids/therapeutic use , Aged , Angina Pectoris/physiopathology , Coronary Circulation/physiology , Echocardiography, Doppler , Endothelial Growth Factors/blood , Humans , Middle Aged , Plasmids/blood , Vascular Endothelial Growth Factor A
17.
Clin Sci (Lond) ; 100(2): 137-43, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11171281

ABSTRACT

We tested the hypothesis that the extent of signs of ischaemia detected by vectorcardiography (VCG) during elective coronary angioplasty (percutaneous transluminal coronary angioplasty; PTCA) is related to systolic and diastolic myocardial velocities, as determined by tissue Doppler echocardiography. A total of 15 patients undergoing PTCA (12 men/three women; age 61+/-9 years), without prior myocardial infarction and with an ejection fraction of >50%, were included. The balloon inflation was repeated three times, with minimum intervals of 2 min between inflations. Tissue Doppler echocardiography was performed, in an apical two- or four-chamber view, before and at the end of each inflation. Peak systolic velocity, time-to-peak systolic velocity (TTP), peak early (E(m)) and late (A(m)) diastolic velocities, the E(m)/A(m) ratio and isovolumic relaxation time were measured in the basal segments of the left ventricle. VCG recordings were carried out during the whole procedure. ST vector magnitude (ST-VM) and ST change vector magnitude (STC-VM) were monitored. The total duration and area of each VCG change during inflation were calculated for each patient. Isovolumic relaxation time, peak E(m) and A(m) values and the E(m)/A(m) ratio did not change significantly during inflation. Peak systolic velocity decreased (6.7+/-2.0 to 5.3+/-1.9 cm/s; P<0.001) and TTP increased (157+/-60 to 192+/-60 ms; P<0.01) during inflation. Both STC-VM time (r=-0.68, P<0.01) and STC-VM area (r=-0.68, P<0.01) were related to peak systolic velocity during inflation. STC-VM time was also related (r=0.55, P<0.05) to the difference in peak systolic velocity during compared with before inflation. ST-VM was less closely related to peak systolic velocity. Thus the duration and degree of ischaemia, as measured by VCG, are related to peak systolic velocity in the basal segments of the left ventricle.


Subject(s)
Angioplasty, Balloon, Coronary/adverse effects , Myocardial Ischemia/etiology , Aged , Blood Flow Velocity , Echocardiography, Doppler , Female , Hemodynamics/physiology , Humans , Male , Middle Aged , Myocardial Ischemia/diagnosis , Myocardial Ischemia/physiopathology , Systole/physiology , Time Factors , Vectorcardiography , Ventricular Function, Left/physiology
18.
J Intern Med ; 250(5): 373-81, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11887971

ABSTRACT

OBJECTIVE: To test the safety and bioactivity of phVEGF-A165 after intramyocardial injection during 12-month follow-up. DESIGN: Open-labelled study. SUBJECTS: Inclusion criteria were angina pectoris, Canadian Cardiovascular Society (CCS) class III-IV, unamenable to further revascularization, ejection fraction (EF) >30%, perfusion defects extending over >10% of the anterolateral left ventricle wall detectable with adenosine single photon emission computerized tomography (SPECT) and at least one patent vessel visible by coronary angiography. Seven of 39 patients referred for gene therapy were included. INTERVENTION: Via a mini-thoracotomy under general anaesthesia. phVEGF-A165 was injected directly into the myocardium at four sites in the anterolateral region of the left ventricle. RESULTS: Operative procedures were uneventful. Perioperative release of myocardial markers and electrocardiogram (ECG) changes were detected in two patients. There were no perioperative deaths but one patient died 7 months postoperatively because of myocardial infarction. Plasma vascular endothelial growth factor (VEGF)-A levels increased two to threefold peaking 6 days postoperatively (P < 0.004) and returning to baseline by day 30. A significant reduction in angina pectoris was reported. The CCS class improved from 3.3+/-0.2 to 1.9+/-0.3 (P < 0.01) and nitroglycerine intake decreased from 39+/-15 to 12+/-5 tablets week(-1) (P < 0.001) 2 months after gene transfer. Improvements remained after 12 months when nitroglycerine consumption approached zero. Improved myocardial function in the phVEGF-A165 injection region was documented in all patients (P < 0.016) by tissue velocity imaging (TVI). Reduced reversible ischaemia was detected by adenosine SPECT in four patients. Improved collateralization was detected in four patients with coronary angiography. CONCLUSION: Intramyocardial injection of phVEGF-A165 is safe and may lead to improved myocardial perfusion and function with longstanding symptomatic relief in end-stage angina pectoris. Based on these results this therapeutic potential is being tested in a double-blind placebo controlled multicentre trial.


Subject(s)
Angina Pectoris/drug therapy , Coronary Artery Disease/drug therapy , Endothelial Growth Factors/administration & dosage , Genetic Therapy , Plasmids/administration & dosage , Aged , Angina Pectoris/diagnosis , Angina Pectoris/surgery , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Endothelial Growth Factors/pharmacokinetics , Endothelial Growth Factors/therapeutic use , Female , Follow-Up Studies , Gene Transfer Techniques , Humans , Injections, Intramuscular , Male , Middle Aged , Plasmids/pharmacokinetics , Plasmids/therapeutic use , Thoracotomy , Time Factors , Vascular Endothelial Growth Factor A
19.
Lakartidningen ; 97(46): 5302-4, 5307-9, 2000 Nov 15.
Article in Swedish | MEDLINE | ID: mdl-11116868

ABSTRACT

Echocardiography is presently a feasible method for quantitative estimation of intracardiac flows, pressure levels and for hemodynamic evaluation of valvular disease. The evaluation of regional myocardial function is still based on subjective scrutiny, and no routine method for the estimation of myocardial blood flow is available. We present an overview of newly developed techniques that are beginning to gain purchase in clinical practice. The use of native second harmonic imaging to improve image quality and of tissue Doppler to provide objective measurements of regional myocardial function is discussed. This article describes the transformation of tissue Doppler information into parametric images as in strain rate imaging, and overviews the use of ultrasound contrast agents. Used together with new imaging modalities, myocardial contrast echocardiography holds promise for future quantification of myocardial blood volume and flow. Other emerging echocardiographic technologies discussed are non-invasive measurement of coronary flow reserve and three dimensional cineloop visualization, developed to increase our understanding of cardiovascular physiological and anatomical coupling.


Subject(s)
Echocardiography/trends , Contrast Media , Echocardiography/methods , Echocardiography, Doppler/trends , Echocardiography, Doppler, Color/trends , Echocardiography, Three-Dimensional/trends , Humans , Myocardial Reperfusion , Research
20.
J Cardiothorac Vasc Anesth ; 14(4): 383-7, 2000 Aug.
Article in English | MEDLINE | ID: mdl-10972601

ABSTRACT

OBJECTIVE: To investigate retrograde and antegrade crystalloid cardioplegia in terms of cardiac cooling and postoperative cardiac function. DESIGN: Prospective, randomized, and blinded. SETTING: University hospital. PARTICIPANTS: Twenty male patients with triple-vessel disease and proximal occlusion of the circumflex or the left anterior descending coronary artery. INTERVENTIONS: Left ventricular ejection fraction at rest and during exercise was evaluated by nuclear ventriculography the day before and 3 months after surgery. After induction of anesthesia and hourly for the first 5 postoperative hours, hemodynamic, echocardiographic, and electrocardiographic data were acquired. Myocardial temperature was measured with needle thermistors in 3 myocardial regions. MEASUREMENTS AND MAIN RESULTS: Demographic and temperature data were analyzed by t-test. Hemodynamic and echocardiographic data were analyzed by analysis of variance. The groups were similar in baseline characteristics. Retrograde cardioplegia cooled the region distal to an occlusion better than antegrade cardioplegia (9.6 degrees C +/- 4.8 degrees C v 21.8 degrees C +/- 5.9 degrees C; p < 0.01). Hemodynamic, echocardiographic, and electrocardiographic data did not differ between the groups. Three months after surgery, the retrograde cardioplegia group showed a higher left ventricular ejection fraction at rest (58% +/- 10% v 47% +/- 10%; p < 0.02) and during exercise (58% +/- 13% v 47% +/- 10%; p < 0.05) compared with the antegrade cardioplegia group. CONCLUSIONS: Retrograde cardioplegia provides more homogenous myocardial cooling than antegrade cardioplegia in hearts with coronary artery occlusions. The use of retrograde cardioplegia seems to benefit long-term left ventricular function.


Subject(s)
Cardioplegic Solutions , Coronary Disease/surgery , Heart Arrest, Induced/methods , Potassium Compounds , Ventricular Function, Left , Double-Blind Method , Echocardiography , Electroencephalography , Hemodynamics , Humans , Male , Prospective Studies , Stroke Volume , Systole
SELECTION OF CITATIONS
SEARCH DETAIL
...