Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rapid Commun Mass Spectrom ; 15(3): 191-202, 2001.
Article in English | MEDLINE | ID: mdl-11180550

ABSTRACT

This article discusses the features of a newly developed matrix-assisted laser desorption/ionization quadrupole/time-of-flight (MALDI-QqTOF) mass spectrometer that is useful in the analysis of phosphorylated peptides. Aliquots of beta-casein, a commonly used phosphorylated protein standard, were digested with trypsin directly on a non-porous polyurethane membrane used as sample support in MALDI-QqTOF mass spectrometry (MS) experiments. Although a complete peptide map was obtained, it was difficult to obtain sequence information for some of the tryptic fragments, in particular T1-2, which bears four phosphate groups and is thus difficult to ionize in positive mode. This article focuses on the sequencing of this particular fragment by comparing MS/MS spectra obtained using different precursor ions. These precursors associated with T1-2 were [M + H](+), [M + H](2+), and [M + H - nH(3)PO(4)](+) ions. Typically, phosphorylated ions showed facile unimolecular losses of phosphoric acid moieties, and produced limited backbone fragmentation. The abundance of [M + H](2+) ions of T1-2 in the full mass spectrum was low relative to that of [M + H](+). [M + H - 4H(3)PO(4)](+) ions as MS/MS precursors underwent backbone fragmentations, with phosphoserine residues transformed into dehydroalanines or serines. Unusual b + 18 u fragments were observed, although only for segments with previously phosphorylated serines. These partly interfered with c-ions, and were noticeable due to overlapping isotopic envelopes. It was possible to establish the sequence of phosphorylated tryptic fragment T1-2 and the location of phosphate groups using the mass of dehydroalanine residues (69 Da) and b + 18 u fragments as markers. All MS and MS/MS spectra obtained with fully phosphorylated beta-casein were compared with spectra acquired with dephosphorylated beta-casein obtained commercially. These comparisons helped assess the spectral differences caused by the presence of phosphate groups. Also, they highlighted the potential usefulness of conducting dephosphorylation directly on the probe prior to MALDI analysis in future studies.


Subject(s)
Caseins/analysis , Membranes, Artificial , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation , Phosphates/analysis , Phosphorylation , Polyurethanes , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
2.
Rapid Commun Mass Spectrom ; 14(12): 1047-57, 2000.
Article in English | MEDLINE | ID: mdl-10861986

ABSTRACT

A matrix-assisted laser desorption/ionization (MALDI) source has been coupled to a tandem quadrupole/time-of-flight (QqTOF) mass spectrometer by means of a collisional damping interface. Mass resolving power of about 10,000 (FWHM) and accuracy in the range of 10 ppm are observed in both single-MS mode and MS/MS mode. Sub-femtomole sensitivity is obtained in single-MS mode, and a few femtomoles in MS/MS mode. Both peptide mass mapping and collision-induced dissociation (CID) analysis of tryptic peptides can be performed from the same MALDI target. Rapid spectral acquisition (a few seconds per spectrum) can be achieved in both modes, so high throughput protein identification is possible. Some information about fragmentation patterns was obtained from a study of the CID spectra of singly charged peptides from a tryptic digest of E. coli citrate synthase. Reasonably successful automatic sequence prediction (>90%) is possible from the CID spectra of singly charged peptides using the SCIEX Predict Sequence routine. Ion production at pressures near 1 Torr (rather than in vacuum) is found to give reduced metastable fragmentation, particularly for higher mass molecular ions. Copyright 2000 John Wiley & Sons, Ltd.

SELECTION OF CITATIONS
SEARCH DETAIL
...