Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bone Joint J ; 99-B(2): 192-198, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28148660

ABSTRACT

AIMS: We carried out a further study of the long-term results of the cemented Exeter femoral component in patients under the age of 40 with a mean follow-up of 13.6 years (10 to 20). PATIENTS AND METHODS: We reviewed our original cohort of 104 cemented Exeter stems in 78 consecutive patients with a mean age of 31 years (16 to 39). Only one patient was lost to radiological follow-up. RESULTS: A total of six patients (eight hips) had died for reasons unrelated to their surgery. There had been one further periprosthetic fracture from a fall and one fractured femoral stem. No revisions for aseptic loosening were undertaken during the whole study period. Overall, 11 hips had progressive radiolucent lines in one or more zones. The Kaplan Meier survival percentages at ten and 17 years were 97.1% (95% confidence interval (CI) 91.3 to 99.1) and 92.1% (95% CI 74.1 to 97.8) with revision for any reason as the endpoint, and 100% at both ten and 17 years with aseptic loosening (95% CI 83.8 to 100) as the endpoint. No additional hips were classified as radiologically loose. CONCLUSION: The Exeter femoral component continues to function satisfactorily in young patients for up to 17 years after surgery. Cite this article: Bone Joint J 2017;99-B:192-8.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Adolescent , Adult , Cementation , Femur/surgery , Follow-Up Studies , Humans , Prosthesis Design , Prosthesis Failure , Young Adult
2.
Bone Joint J ; 96-B(9): 1207-13, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25183592

ABSTRACT

In this retrospective study, we investigated the results of revision total hip replacement (THR) using a cemented long-stemmed Exeter femoral component, with a minimum length of 205 mm in patients with extensive femoral bone defects. The study included 37 consecutive patients with a mean age of 76 years (39 to 93) and a mean follow-up of nine years (5 to 16). A total of 26 patients (70%) had a pre-operative Endo-Klinik score of 3 or 4. Impaction bone grafting was used in 24 patients (65%). At the time of evaluation, 22 patients (59%) were still alive and were evaluated clinically and radiologically. A total of 14 patients died during follow-up and their data were included until the time of their death. One reconstruction failed after five years and five months owing to recurrent dislocation: the hip was converted to an excision arthroplasty. Intra-operative fractures or fissures were encountered in nine patients (24%), but none occurred during impaction of the bone graft. Post-operative peri-prosthetic fractures occurred in two patients (5%); both were treated with plate fixation. At nine years, survival with the endpoint of all-cause re-revision was 96.3% (95% CI 76.4 to 99.5); including re-operations for any reason, it was 80.7% (95% CI 56.3 to 92.3%). There were no re-revisions for aseptic loosening. The survival of long stem cemented femoral components following revision THR is satisfactory in a fragile population with extensive femoral defects.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Dislocation/surgery , Hip Prosthesis/adverse effects , Prosthesis Failure , Prosthesis-Related Infections/surgery , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Bone Cements , Female , Follow-Up Studies , Hip Dislocation/etiology , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Periprosthetic Fractures/epidemiology , Postoperative Complications/epidemiology , Postoperative Complications/surgery , Reoperation/statistics & numerical data , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS