Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Langenbecks Arch Surg ; 409(1): 188, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38896330

ABSTRACT

BACKGROUND: The Trans Rectus Sheath Extra-Peritoneal Procedure (TREPP) is an open procedure in which the mesh is placed in the preperitoneal space and is therefore associated with less chronic post-operative inguinal pain. TREPP is primarily performed under general or spinal anesthesia, however, it is also possible to perform under sedation and local anesthesia with potentially advantages. This retrospective feasibility pilot study investigates the safety and efficiency of TREPP under local anesthesia in the outpatient clinic in comparison with Lichtenstein. METHODS: Between 2019 and 2022, all patients who underwent an elective inguinal hernia repair under local anesthesia in the outpatient clinic operation theatre were assessed. 34 patients in the TREPP group and 213 patients in the Lichtenstein group were included. Outcomes were complications, operating time, theatre time, and early inguinal hernia recurrence within 8 weeks and 6 months post-operatively. RESULTS: No significant differences in complications such as wound infection, hematoma, seroma, urine retention and early recurrence between TREPP and Lichtenstein were found. Post-operative pain at 8 weeks was not significantly higher after Lichtenstein (8.8% vs. 18.8%, P = 0.22). Operating time (21.0 (IQR: 16.0-27.3) minutes vs. 39.0 (IQR: 31.5-45.0) minutes, P < 0.001) and theatre time (37.5 (IQR: 30.8-42.5) minutes vs. 54.0 (IQR: 46.0-62.0) minutes, P < 0.001) was significantly shorter for TREPP. CONCLUSION: This pilot study showed that TREPP appears to be feasible to perform safely under local anesthesia with comparable complication rates and substantially shorter operation time than Lichtenstein. These results justify further research with a larger study population and a longer period of follow up in order to provide firm conclusions.


Subject(s)
Anesthesia, Local , Feasibility Studies , Hernia, Inguinal , Herniorrhaphy , Humans , Hernia, Inguinal/surgery , Male , Herniorrhaphy/methods , Herniorrhaphy/adverse effects , Middle Aged , Female , Pilot Projects , Retrospective Studies , Aged , Surgical Mesh , Ambulatory Surgical Procedures/methods , Adult , Operative Time , Rectus Abdominis/transplantation , Treatment Outcome , Conscious Sedation , Ambulatory Care Facilities
2.
Hernia ; 27(5): 1203-1208, 2023 10.
Article in English | MEDLINE | ID: mdl-37548799

ABSTRACT

BACKGROUND: The Dextile Anatomical mesh (Medtronic) is a polypropylene heavyweight mesh and has a 3D patented anatomical shape which adapts to the contours of the extra-peritoneal inguinal region without the need for fixation, potentially reducing the risk of hernia recurrence and chronic post-operative pain. This retrospective study will be the first study to assess the outcomes of the Dextile Anatomical mesh compared to another three-dimensional mesh, the 3DMax mesh (Bard). METHODS: Between 2019 and 2022, all patients who underwent an elective unilateral inguinal hernia repair were assessed. 416 patients in the Dextile Anatomical mesh group and 540 patients in the 3DMax mesh group were included. Outcomes were intra- and post-operative complications, inguinal hernia recurrence and chronic post-operative inguinal pain. RESULTS: No significant differences were found between the two groups regarding intra- and post-operative complications including wound infection, antibiotic use, hematoma, seroma, urinary retention and delayed wound healing. 1-year recurrence rate was comparable for the Dextile Anatomical mesh group and the 3DMax mesh group, respectively, 3.8% and 3.0%, P = 0.45. Chronic post-operative inguinal pain was similar for the Dextile Anatomical mesh (3.4%) and the 3DMax mesh (3.0%), P = 0.72. CONCLUSION: This retrospective study comparing the relatively new Dextile Anatomical mesh (Medtronic) with the 3D Max mesh (Bard) in unilateral inguinal hernia repair showed that both meshes are safe and effective to use. There were no significant differences in intra-operative outcomes, recurrence rates and chronic post-operative inguinal pain.


Subject(s)
Hernia, Inguinal , Laparoscopy , Humans , Hernia, Inguinal/complications , Surgical Mesh/adverse effects , Retrospective Studies , Herniorrhaphy/adverse effects , Herniorrhaphy/methods , Pain, Postoperative/etiology , Pain, Postoperative/surgery , Recurrence , Polypropylenes , Laparoscopy/adverse effects , Treatment Outcome
3.
Acta Chir Belg ; 123(3): 301-304, 2023 Jun.
Article in English | MEDLINE | ID: mdl-34474633

ABSTRACT

BACKGROUND: Pneumomediastium is a rare complication of pregnancy or labor. METHODS: Here, we report our findings in a case report (gravid 5, para 2, gestational age 33 + 4 weeks) and narratively review the current literature on pneumomediastinum in pregnancy or labor. RESULTS: Our case is the first case that experienced pneumomediastinum after relatively limited exposure to barotrauma in the current pregnancy. Other reports describe pneumomediastinum after hyperemesis gravidarum or during labor. Treatment is usually conservatively due to the trauma mechanism of barotrauma to the alveoli. CONCLUSION: Physicians should be aware of the possibility of pneumomediastinum in pregnant women with acute thoracic pain in cases of (previous) hyperemesis gravidarum or during labor.


Subject(s)
Hyperemesis Gravidarum , Mediastinal Emphysema , Pregnancy , Female , Humans , Infant , Hyperemesis Gravidarum/complications , Hyperemesis Gravidarum/therapy , Mediastinal Emphysema/diagnostic imaging , Mediastinal Emphysema/etiology , Mediastinal Emphysema/therapy
5.
Eur J Vasc Endovasc Surg ; 50(3): 313-9, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26027898

ABSTRACT

OBJECTIVE: To compare the mid-term results of endovascular aortic aneurysm repair (EVAR) for ruptured abdominal aortic aneurysms (RAAAs) in patients with favourable aortic neck anatomy (FNA) and hostile aortic neck anatomy (HNA). METHODS: Patients treated for a RAAA in a high volume endovascular centre in the Netherlands between February 2009 and January 2014 were identified retrospectively and divided into two groups based on aortic neck anatomy, FNA and HNA. HNA was defined as RAAA with a proximal neck of <10 mm, or a proximal neck of 10-15 mm with a suprarenal angulation (α) >45° and/or an infrarenal angulation (ß) >60°, or a proximal neck of >15 mm combined with α >60° and/or ß >75°. Patient demographics, procedure details, 30 day and 1 year outcomes were recorded. RESULTS: Of 39 included patients, 17 (44%) had HNA. Technical success was 100% for FNA and 88% for HNA (p = .184). There were no type IA endoleaks on completion angiography in either group; however, more adjunctive procedures were necessary for intra-operative type IA endoleaks in the HNA group (24% vs. 0%, p = .029). Thirty day mortality rates were comparable, FNA 14% vs. HNA 12% (p = 1.000). There were no statistically significant differences at 1 year follow up in type I endoleaks, secondary endovascular procedures, or all cause mortality. CONCLUSION: Emergency EVAR provides excellent results for treatment of RAAA patients with both FNA and HNA. EVAR in RAAAs with HNA is technically feasible and safe in experienced endovascular centres. Article history.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Rupture/surgery , Endovascular Procedures , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Abdominal/mortality , Aortic Rupture/diagnosis , Aortic Rupture/mortality , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Hospitals, High-Volume , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Netherlands , Retrospective Studies , Risk Factors , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
6.
J Cardiovasc Surg (Torino) ; 55(5): 699-704, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24846671

ABSTRACT

AIM: The aim of this study was to collect clinical information on the performance of the Endurant® (II) Stent Graft System for endovascular repair in anatomically challenging infrarenal aneurysms, and to critically assess whether the current instructions for anatomic eligibility for endovascular treatment with this system are still applicable. METHODS: Initiated by doctors, EAGLE is a prospective, non-interventional study, aiming to enrol 250 patients in 20 experienced centres across several countries worldwide. EAGLE focuses on patients with challenging angulation or neck length. To minimize the risk of selection bias and enhance data quality, EAGLE eligibility will be determined by an independent core-lab and efforts will be made to secure consecutive enrolment of challenging cases. The EAGLE database is designed to merge with the on-going ENGAGE database, which enables comparative analysis of cases and results. RESULTS: The primary endpoint is treatment success at 30 days, 12 months and yearly up to 5 years postimplant. CONCLUSION: Separate studies on the performance of EVAR in challenging anatomy are necessary to demonstrate safety and effectiveness of the latest generation stent-grafts, which is essential in making a balanced judgment about the optimal management of AAAs.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Registries , Research Design , Stents , Aortic Aneurysm, Abdominal/diagnosis , Blood Vessel Prosthesis Implantation/adverse effects , Databases, Factual , Endovascular Procedures/adverse effects , Humans , Prospective Studies , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...