Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Eur Radiol ; 32(6): 4292-4303, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35029730

ABSTRACT

OBJECTIVES: To compare the lung CT volume (CTvol) and pulmonary function tests in an interstitial lung disease (ILD) population. Then to evaluate the CTvol loss between idiopathic pulmonary fibrosis (IPF) and non-IPF and explore a prognostic value of annual CTvol loss in IPF. METHODS: We conducted in an expert center a retrospective study between 2005 and 2018 on consecutive patients with ILD. CTvol was measured automatically using commercial software based on a deep learning algorithm. In the first group, Spearman correlation coefficients (r) between forced vital capacity (FVC), total lung capacity (TLC), and CTvol were calculated. In a second group, annual CTvol loss was calculated using linear regression analysis and compared with the Mann-Whitney test. In a last group of IPF patients, annual CTvol loss was calculated between baseline and 1-year CTs for investigating with the Youden index a prognostic value of major adverse event at 3 years. Univariate and log-rank tests were calculated. RESULTS: In total, 560 patients (4610 CTs) were analyzed. For 1171 CTs, CTvol was correlated with FVC (r: 0.86) and TLC (r: 0.84) (p < 0.0001). In 408 patients (3332 CT), median annual CTvol loss was 155.7 mL in IPF versus 50.7 mL in non-IPF (p < 0.0001) over 5.03 years. In 73 IPF patients, a relative annual CTvol loss of 7.9% was associated with major adverse events (log-rank, p < 0.0001) in univariate analysis (p < 0.001). CONCLUSIONS: Automated lung CT volume may be an alternative or a complementary biomarker to pulmonary function tests for the assessment of lung volume loss in ILD. KEY POINTS: • There is a good correlation between lung CT volume and forced vital capacity, as well as for with total lung capacity measurements (r of 0.86 and 0.84 respectively, p < 0.0001). • Median annual CT volume loss is significantly higher in patients with idiopathic pulmonary fibrosis than in patients with other fibrotic interstitial lung diseases (155.7 versus 50.7 mL, p < 0.0001). • In idiopathic pulmonary fibrosis, a relative annual CT volume loss higher than 9.4% is associated with a significantly reduced mean survival time at 2.0 years versus 2.8 years (log-rank, p < 0.0001).


Subject(s)
Idiopathic Pulmonary Fibrosis , Lung Diseases, Interstitial , Humans , Idiopathic Pulmonary Fibrosis/diagnostic imaging , Lung/diagnostic imaging , Lung Diseases, Interstitial/diagnostic imaging , Lung Volume Measurements , Retrospective Studies , Tomography, X-Ray Computed/methods , Vital Capacity
3.
Diagn Interv Imaging ; 102(5): 305-312, 2021 May.
Article in English | MEDLINE | ID: mdl-33610503

ABSTRACT

PURPOSE: The purpose of this study was to characterize the technical capabilities and feasibility of a large field-of-view clinical spectral photon-counting computed tomography (SPCCT) prototype for high-resolution (HR) lung imaging. MATERIALS AND METHODS: Measurement of modulation transfer function (MTF) and acquisition of a line pairs phantom were performed. An anthropomorphic lung nodule phantom was scanned with standard (120kVp, 62mAs), low (120kVp, 11mAs), and ultra-low (80kVp, 3mAs) radiation doses. A human volunteer underwent standard (120kVp, 63mAs) and low (120kVp, 11mAs) dose scans after approval by the ethics committee. HR images were reconstructed with 1024 matrix, 300mm field of view and 0.25mm slice thickness using a filtered-back projection (FBP) and two levels of iterative reconstruction (iDose 5 and 9). The conspicuity and sharpness of various lung structures (distal airways, vessels, fissures and proximal bronchial wall), image noise, and overall image quality were independently analyzed by three radiologists and compared to a previous HR lung CT examination of the same volunteer performed with a conventional CT equipped with energy integrating detectors (120kVp, 10mAs, FBP). RESULTS: Ten percent MTF was measured at 22.3lp/cm with a cut-off at 31lp/cm. Up to 28lp/cm were depicted. While mixed and solid nodules were easily depicted on standard and low-dose phantom images, higher iDose levels and slice thicknesses (1mm) were needed to visualize ground-glass components on ultra-low-dose images. Standard dose SPCCT images of in vivo lung structures were of greater conspicuity and sharpness, with greater overall image quality, and similar image noise (despite a flux reduction of 23%) to conventional CT images. Low-dose SPCCT images were of greater or similar conspicuity and sharpness, similar overall image quality, and lower but acceptable image noise (despite a flux reduction of 89%). CONCLUSIONS: A large field-of-view SPCCT prototype demonstrates HR technical capabilities and high image quality for high resolution lung CT in human.


Subject(s)
Lung , Tomography, X-Ray Computed , Algorithms , Feasibility Studies , Humans , Image Processing, Computer-Assisted , Lung/diagnostic imaging , Phantoms, Imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted
4.
Eur J Radiol ; 134: 109427, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33307461

ABSTRACT

PURPOSE: To evaluate the technical and diagnostic performance of three dimensional (3D) mDIXON versus 3D inversion recovery (3D VIAB) and 3D spectral presaturation with inversion recovery (3D SPIR) late gadolinium enhancement (LGE) sequences. METHODS: A total of 78 patients (50 males and 28 females, age 49 ± 18 years) with 1.5 T CMR examination including three different 3D LGE sequences (3D mDIXON, 3D VIAB, and 3D SPIR) were evaluated for technical and diagnostic performance by two readers. Qualitative scores and quantitative signal and contrast-to-noise ratios were compared among sequences. Qualitative comparisons were made using Friedman and Wilcoxon signed rank tests. Quantitative comparisons were made using one way ANOVA. Reader agreements were tested using Cohen's Kappa. Any p-value <0.05 was significant. RESULTS: 19 out of 78 patients (24 %) were excluded due to poor (grade 4) image quality and 29 patients were excluded due to absence of LGE. For the remaining 30 patients, free breathing 3D mDIXON showed higher confidence in diagnosis of subepicardial LGE (p-value < 0.05). 3D mDIXON outperformed 3D SPIR in both visualization of LGE (p = 0.02) and quality of fat suppression (p = 0.001). Nevertheless, 3D mDIXON showed lower image quality compared to the other two sequences. CONCLUSION: Free breathing 3D mDIXON is a diagnostic problem-solving tool, especially when making a diagnosis of subepicardial enhancement and/or fat suppression is needed, owing to its high spatial resolution and robust fat suppression. Choice of 3D LGE sequence should be based on patient's breath-hold ability, diagnostic needs, and institutional availability considering the strengths and limitations of each sequence.


Subject(s)
Contrast Media , Gadolinium , Adult , Aged , Female , Humans , Image Enhancement , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Middle Aged
5.
Int J Cardiovasc Imaging ; 30(7): 1347-55, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24928765

ABSTRACT

Flow and pressure variations cause potential changes in magnetic resonance imaging (MRI) signal intensity across the cardiac cycle. Nevertheless, cardiac dynamic contrast-enhanced (perfusion) MRI is performed and analyzed regardless of the cardiac phase. We investigate whether the cardiac phase impacts myocardial and left ventricle (LV) cavity time intensity curves (TICs) at rest and during vasodilatation. Fifteen healthy volunteers (seven females, eight males; mean age: 32.5 ± 9.3 years; age range: 19-49 years) were included in this prospective study. They underwent four separate short-axis multislice (apical, mid and basal) LV perfusion MRI, with different electrocardiogram-triggering during normal vasotone and adenosine-stress. TIC parameters were extracted from the myocardium and the LV cavity. General linear mixed model analyses were used to evaluate their variability according to vasotone, cardiac phase and slice-position. Maximal enhancement and normalized Steepest slopes were higher at stress than at rest (p values <0.001). A similar trend towards higher inflow was shown on systole versus diastole in the LV cavity and diastole versus systole in the myocardium (p < 0.05).These TIC parameters were slice-position dependent, as the inflow decreased from the base to the apex in the LV, and peaked on the mid-slice for the myocardium. There are significant variability of both the LV and the myocardial TICs, with respect to the cardiac cycle phase and the slice position where imaging actually takes place. These appeal to measurement standardization for a better intra- and inter-study reproducibility.


Subject(s)
Coronary Circulation , Hemodynamics , Magnetic Resonance Imaging, Cine , Myocardial Perfusion Imaging/methods , Ventricular Function, Left , Adult , Cardiac-Gated Imaging Techniques , Diastole , Electrocardiography , Female , Heart Rate , Humans , Linear Models , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Reference Values , Reproducibility of Results , Systole , Time Factors , Vasodilation , Vasodilator Agents/therapeutic use , Young Adult
6.
Radiology ; 254(3): 973-81, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20177108

ABSTRACT

PURPOSE: To prospectively determine if superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging could help visualize leukocyte phagocytic activities in human abdominal aortic aneurysms (AAAs). MATERIALS AND METHODS: This study was approved by the institutional ethics committee; all patients gave informed consent. Preoperative MR imaging data, including unenhanced and SPIO-enhanced T1-, T2*-, and T2-weighted transverse images of the entire AAA, obtained 1 hour after contrast enhancement from 15 patients (mean age, 72.7 years +/- 8.2; range, 60-83 years), 10 men (mean age, 73.5 years +/- 7.9; range, 60-83 years) and five women (mean age, 71.2 years +/- 9.4; range 60-82), were retrospectively evaluated. Morphologic appearance and semiquantitative and contrast-to-noise ratio (CNR) analyses of the thrombi were performed. Thrombi were analyzed semiquantitatively at microscopy after staining with hematoxylin-eosin, CD68, and CD66b. Levels of promatrix metalloproteinase (pro-MMP)-2 and pro-MMP-9, MMP-2 and MMP-9, and their mRNA located in the thrombus were assessed by using zymography and quantitative reverse transcriptase polymerase chain reaction analysis. Nonparametric statistics of the Spearman rank correlation were calculated to evaluate correlations between the aneurysm thrombus signal level decrease after SPIO and the levels of CD68(+), CD66b(+) cells, pro-MMP-2 and pro-MMP-9, MMP-2 and MMP-9, and MMP-9 mRNA. RESULTS: The pre-SPIO CNRs in the luminal sublayer of the thrombus and the deeper thrombus were -10.20 +/- 12.69 and -5.68 +/-10.38, respectively. After SPIO, the CNRs decreased to -21.34 +/-13.07 (P < .001) and -12.44 +/- 14.56, respectively (P < .012). There was a significant linear correlation between the thrombus signal level decrease and the levels of CD68(+) and CD66b(+) cells, pro-MMP-9, and MMP-9 mRNA (P < .05). CONCLUSION: MR imaging allows in vivo demonstration of SPIO uptake at the luminal interface of the thrombus. This uptake is correlated to the abundance of leukocytes. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.09090657/-/DC1.


Subject(s)
Aortic Aneurysm/metabolism , Magnetic Resonance Imaging/methods , Phagocytosis/physiology , Thrombosis/metabolism , Aged , Aged, 80 and over , Analysis of Variance , Aortic Aneurysm/physiopathology , Contrast Media/pharmacokinetics , Dextrans , Enzyme Precursors/metabolism , Female , Ferrosoferric Oxide/pharmacokinetics , Gelatinases/metabolism , Humans , Image Enhancement/methods , Immunohistochemistry , Magnetite Nanoparticles , Male , Matrix Metalloproteinase 2/metabolism , Matrix Metalloproteinase 9/metabolism , Middle Aged , Prospective Studies , Retrospective Studies , Reverse Transcriptase Polymerase Chain Reaction , Serine Endopeptidases/metabolism , Statistics, Nonparametric , Thrombosis/physiopathology
7.
AJR Am J Roentgenol ; 192(6): 1531-7, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19457815

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the feasibility and accuracy of accelerated free-breathing and breath-hold gadolinium-enhanced MR angiography of the main renal arteries compared with digital subtraction angiography. MATERIALS AND METHODS: Renal MR angiograms and catheter angiograms of 47 patients (19 men, 28 women; mean age, 68.1 +/- 15.1 years; range, 28-86 years) were reviewed. Thirty-one of the patients underwent free-breathing and 16 underwent breath-hold MR angiography with the same accelerated multiphase imaging protocol. Images were analyzed for examination quality, percentage narrowing of the main renal artery, and visibility of the branches. Diagnostic values of MR angiography were calculated with catheter angiography as the standard of reference. RESULTS: Sixty-five arteries, 24 of which (37%) had > 49% narrowing, were evaluated in the free-breathing group, and 37 arteries, six of which (16%) had > 49% narrowing, were evaluated in the breath-hold group. Comparison with digital subtraction angiography showed 100% (24/24) sensitivity and 95% (39/41) specificity for > 49% renal artery stenosis and 88% sensitivity (15/17) and 100% (48/48) specificity for > 74% renal artery stenosis in the free-breathing group. In the breath-hold group, sensitivity was 100% (6/6) and specificity 97% (30/31) for > 49% renal artery stenosis, and sensitivity was 100% (5/5) and specificity 100% (32/32) for > 74% renal artery stenosis. None of the examinations was nondiagnostic for the main renal arteries, but a smaller number of visible arterial tree subdivisions were found in the free-breathing group (average, 3.64 per patient) than in the breath-hold group (average, 5.87 per patient) (p = 0.035). CONCLUSION: Like breath-hold examinations, accelerated free-breathing MR angiographic examinations are feasible and accurate in evaluation of the main renal arteries.


Subject(s)
Gadolinium DTPA , Hypertension, Renovascular/diagnosis , Magnetic Resonance Angiography/methods , Renal Artery/pathology , Respiratory Mechanics , Adult , Aged , Aged, 80 and over , Contrast Media , Feasibility Studies , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
8.
Radiology ; 248(3): 860-8, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18710980

ABSTRACT

PURPOSE: To prospectively evaluate the learning curves and reading times of inexperienced readers who used the virtual dissection reading method for retrospective computed tomographic (CT) colonography data sets, with and without concurrent computer-aided detection (CAD). MATERIALS AND METHODS: An Institutional Review Board approved this study; informed consent was waived. Four radiologists without experience in CT colonography evaluated 100 optical colonoscopy-proved data sets of 100 patients (49 men, 51 women; mean age, 59 years +/- 13 [standard deviation]; range, 21-85 years) by using the virtual dissection reading method. Two readers used concurrent CAD. Data sets were read during five consecutive 1-day sessions (20 data sets per session). Polyp detection and false-positive rates, receiver operating characteristics (ROCs), and reading times were calculated for individual, CAD group, and non-CAD group readings. Diagnostic values were compared by calculating the 95% confidence intervals (CIs) around the relative risk. Areas under ROC curves (AUCs) (Hanley and McNeil for paired analysis and z statistics for unpaired analysis) and reading times (Wilcoxon signed rank test) were compared across the sessions, within each session and for the whole study. RESULTS: The range of detection rates was 79 of 111 (.71 [95% CI: .61, .79]) to 91 of 111 (.82 [95% CI: .73, .88]). The range of false-positive rates was 17 of 111 (.15 [95% CI: .09, .23]) to 22 of 111 (.20 [95% CI: .12, .28]). All readers' AUCs rose from session 1 to session 4; this rise was significant (P < .05) for the non-CAD group. Only during session 1 was the CAD group AUC (.83) higher than the non-CAD group AUC (.54) (P < .05). Comparison of CAD and non-CAD reading times showed no significant difference for the whole study or during each session (P > .05). CONCLUSION: The virtual dissection reading technique allows short learning curves, which may be improved by the concurrent use of CAD, without significant effect on average reading time.


Subject(s)
Artificial Intelligence , Colonic Polyps/diagnostic imaging , Colonography, Computed Tomographic/methods , Professional Competence , Radiographic Image Interpretation, Computer-Assisted/methods , Task Performance and Analysis , User-Computer Interface , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...